Hybrid testing of lumbar CHARITE discs versus Fusions

被引:86
|
作者
Panjabi, Manohar [1 ]
Malcolmson, George [1 ]
Teng, Edward [1 ]
Tominaga, Yasuhiro [1 ]
Henderson, Gweneth [1 ]
Serhan, Hassan [1 ]
机构
[1] Yale Univ, Sch Med, Dept Orthopaed & Rehabil, Biomech Res Lab, New Haven, CT 06520 USA
关键词
CHARITE artificial disc; hybrid test; adjacent-level effects; biomechanics; lumbar spine;
D O I
10.1097/01.brs.0000260792.13893.88
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. An in vitro human cadaveric biomechanical study. Objectives. To quantify effects on operated and other levels, including adjacent levels, due to CHARITE disc implantations versus simulated fusions, using follower load and the new hybrid test method in flexion-extension and bilateral torsion. Summary of Background Data. Spinal fusion has been associated with long-term accelerated degeneration at adjacent levels. As opposed to the fusion, artificial discs are designed to preserve motion and diminish the adjacent-level effects. Methods. Five fresh human cadaveric lumbar specimens (T12-S1) underwent multidirectional testing in flexion-extension and bilateral torsion with 400 N follower load. Intact specimen total ranges of motion were determined with +/- 10 Nm unconstrained pure moments. The intact range of motion was used as input for the hybrid tests of 5 constructs: 1) CHARITE disc at L5-S1; 2) fusion at L5-S1; 3) CHARITE discs at L4-L5 and L5-S1; 4) CHARITE disc at L4-L5 and fusion at L5-S1; and 5) 2-level fusion at L4-L5-S1. Using repeated-measures single factor analysis of variance and Bonferroni statistical tests ( P < 0.05), intervertebral motion redistribution of each construct was compared with the intact. Results. In flexion-extension, 1-level CHARITE disc preserved motion at the operated and other levels, while 2-level CHARITE showed some amount of other-level effects. In contrast, 1- and 2-level fusions increased other-level motions (average, 21.0% and 61.9%, respectively). In torsion, both 1- and 2-level discs preserved motions at all levels. The 2-level simulated fusion increased motions at proximal levels (22.9%), while the 1- level fusion produced no significant changes. Conclusions. In general, CHARITE discs preserved operated and other-level motions. Fusion simulations affected motion redistribution at other levels, including adjacent levels.
引用
收藏
页码:959 / 966
页数:8
相关论文
共 50 条
  • [21] SEGMENTAL (FLOATING) LUMBAR SPINE FUSIONS
    BRODSKY, AE
    HENDRICKS, RL
    KHALIL, MA
    DARDEN, BV
    BROTZMAN, TT
    SPINE, 1989, 14 (04) : 447 - 450
  • [22] Interbody, posterior, and combined lumbar fusions
    Fraser, RD
    SPINE, 1995, 20 (24) : S167 - S177
  • [23] Interobserver variability in grading lumbar fusions
    Hamill, CL
    Simmons, ED
    JOURNAL OF SPINAL DISORDERS, 1997, 10 (05): : 387 - 390
  • [24] Interbody Fusions in the Lumbar Spine: A Review
    Verma, Ravi
    Virk, Sohrab
    Qureshi, Sheeraz
    HSS JOURNAL, 2020, 16 (02) : 162 - 167
  • [25] ANTERIOR INTERVERTEBRAL LUMBAR SPINE FUSIONS
    SHANEWIS.RP
    PACIFIC MEDICINE AND SURGERY, 1963, 71 (05): : 212 - &
  • [26] ANTERIOR INTERVERTEBRAL LUMBAR SPINE FUSIONS
    SHANEWISE, RP
    WESTERN JOURNAL OF SURGERY OBSTETRICS AND GYNECOLOGY, 1963, 71 (05): : 212 - +
  • [27] BIOMECHANICS OF THE SB CHARITE LUMBAR INTERVERTEBRAL-DISK ENDOPROSTHESIS
    BUTTNERJANZ, K
    SCHELLNACK, K
    ZIPPEL, H
    INTERNATIONAL ORTHOPAEDICS, 1989, 13 (03) : 173 - 176
  • [28] Effects of Charite artificial disc on the implanted and adjacent spinal segments mechanics using a hybrid testing protocol
    Goel, VK
    Grauer, JN
    Patel, TC
    Biyani, A
    Sairyo, K
    Vishnubhotla, S
    Matyas, A
    Cowgill, I
    Shaw, M
    Long, R
    Dick, D
    Panjabi, MM
    Serhan, H
    SPINE, 2005, 30 (24) : 2755 - 2764
  • [29] OPERATIVE TREATMENT OF PROLAPSED LUMBAR DISCS
    DUTOIT, GT
    ROUX, D
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1960, 42 (04): : 860 - 860
  • [30] Spontaneous regression of herniated lumbar discs
    Kim, Eric S.
    Oladunjoye, Azeem O.
    Li, Jay A.
    Kim, Kee D.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (06) : 909 - 913