Temporal changes and clinical significance of peridevice leak following left atrial appendage occlusion with Amplatzer devices

被引:16
|
作者
Korsholm, Kasper [1 ]
Jensen, Jesper M. [1 ]
Norgaard, Bjarne L. [1 ]
Nielsen-Kudsk, Jens E. [1 ]
机构
[1] Aarhus Univ Hosp, Dept Cardiol, Palle Juul Jensens Blvd 99, DK-8200 Aarhus N, Denmark
关键词
CLLA-closure; left atrial appendage; SHDI-structural heart disease intervention; STR-stroke; TTE; TEE; THROMBUS; CLOSURE; IMPACT; ECHOCARDIOGRAPHY; SURVEILLANCE; ANGIOGRAPHY; WATCHMAN; REGISTRY;
D O I
10.1002/ccd.30178
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The natural history of peridevice leak (PDL) following left atrial appendage occlusion (LAAO) is unknown. This study sought to investigate changes of PDL from 2 until 12 months after LAAO, using cardiac computed tomography (CT), and to assess the potential association between persistent PDL and clinical outcomes Methods Single-center observational study of Amplatzer LAAO implants between 2010 and 2017 (n = 206). Patients with 2 and 12 months cardiac CT were included in the study (n = 153). Images were blindly analyzed. PDL was characterized by frequency and size at the device disc, lobe, and left atrial appendage contrast patency. Patients were followed for the composite outcome of ischemic stroke, transient ischemic attack, systemic embolism, or all-cause death. Median follow up from LAAO was 3.1 (2.3-4.3) years. Results Contrast patency was present in 101 (66%) and 72 (47%) (p < 0.001) at 2 and 12 months, respectively. PDL was identified at the disc in 103 (67%) patients at 2 months versus 93 (61%) at 12 months (p = 0.08), and at the lobe in 29 (19%) at both time points. PDL area at the disc did not change significantly over time, increment $\unicode{x02206}$ area: -8.95 mm (95% confidence interval [CI]: -18.9; 1.01) p = 0.08. Permanent atrial fibrillation was independently associated with persistent PDL. Persistent versus no PDL was associated with a 62% worse clinical outcome, however not statistically significant, hazard ratio (HR): 1.62 (95% CI: 0.9-2.93), p = 0.11. Conclusion Persistent PDL was frequently observed following LAAO with Amplatzer devices. The PDL frequency and size appeared unchanged between 2 and 12 months. Persistent PDL was not significantly associated with worse clinical outcomes, yet this needs further delineation in future studies.
引用
收藏
页码:2071 / 2079
页数:9
相关论文
共 50 条
  • [1] Peridevice Leak Following Amplatzer Left Atrial Appendage Occlusion Cardiac Computed Tomography Classification and Clinical Outcomes
    Korsholm, Kasper
    Jensen, Jesper Moller
    Norgaard, Bjarne Linde
    Samaras, Athanasios
    Saw, Jacqueline
    Berti, Sergio
    Tzikas, Apostolos
    Nielsen-Kudsk, Jens Erik
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (01) : 83 - 93
  • [2] Management of Peridevice Leak Following Left Atrial Appendage Occlusion
    Alkhouli, Mohamad
    Chaker, Zakeih
    Al-Hajji, Muhammad
    Sengupta, Partho P.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (07) : 967 - 969
  • [3] Temporal Changes and Clinical Implications of Delayed Peridevice Leak Following Left Atrial Appendage Closure
    Afzal, Muhammad R.
    Gabriels, James K.
    Jackson, Gregory G.
    Chen, Lu
    Buck, Benjamin
    Campbell, Sandra
    Sabin, Dawn F.
    Goldner, Bruce
    Ismail, Haisam
    Liu, Christopher F.
    Patel, Apoor
    Beldner, Stuart
    Daoud, Emile G.
    Hummel, John D.
    Ellis, Christopher R.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2022, 8 (01) : 15 - 25
  • [4] LEFT ATRIAL APPENDAGE PERIDEVICE LEAK CLOSURE WITH AMPLATZER PLUG
    Qasim, Muhammad
    Tariq, Rana
    Bang, Vigyan
    Hornsby, Kyle
    Mattson, Scott
    Zawacki, Kevin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 2505 - 2505
  • [5] Peridevice Leak After Left Atrial Appendage Occlusion
    Alkhouli, Mohamad
    De Backer, Ole
    Ellis, Christopher R.
    Nielsen-Kudsk, Jens Erik
    Sievert, Horst
    Natale, Andrea
    Lakkireddy, Dhanunjaya
    Holmes, David R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (06) : 627 - 642
  • [6] Peridevice leak: Achilles' heel of left atrial appendage occlusion?
    Cilingiroglu, Mehmet
    Inanc, Ibrahim
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (07) : 2080 - 2081
  • [7] Percutaneous Closure of Peridevice Leak After Left Atrial Appendage Occlusion
    Alkhouli, Mohamad
    Alqahtani, Fahad
    Kazienko, Brian
    Olgers, Kassandra
    Sengupta, Partho P.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (11) : E83 - E85
  • [8] Left Atrial Appendage Peridevice Leak Presenting With Stroke
    Fender, Erin A.
    El Sabbagh, Abdallah
    Al-Hijji, Mohammed
    Holmes, David R., Jr.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (14) : E123 - E125
  • [9] INCIDENCE AND TEMPORAL EVOLUTION OF PERIDEVICE LEAK WITH WATCHMAN FLX LEFT ATRIAL APPENDAGE CLOSURE
    Bhuta, Sapan
    Poliner, Michael
    Horbal, Piotr
    Sirinvaravong, Natee
    Sleiman, Jose
    Lee, John
    Wallace, Grant
    Daoud, Emile G.
    Augostini, Ralph S.
    Weiss, Raul
    Kalbfleisch, Steven Jack
    Savona, Salvatore
    Houmsse, Mahmoud
    Okabe, Toshimasa
    Afzal, Muhammad Rizwan
    Hummel, John D.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 44 - 44
  • [10] Incidence and temporal evolution of delayed peridevice leak after left atrial appendage closure
    Bhuta, Sapan
    Carlen, Austin
    Savona, Salvatore J.
    Augostini, Ralph S.
    Kalbfleisch, Steven J.
    Houmsse, Mahmoud
    Daoud, Emile G.
    Hummel, John D.
    Afzal, Muhammad R.
    HEART RHYTHM, 2024, 21 (11) : 2118 - 2125