Multi-source inverse-geometry CT: from system concept to research prototype

被引:11
|
作者
De Man, Bruno [1 ]
Caiafa, Antonio [1 ]
Cao, Yang [1 ]
Frutschy, Kristopher [1 ]
Harrison, Daniel [1 ]
Inzinna, Lou [1 ]
Longtin, Randy [1 ]
Neculaes, Bogdan [1 ]
Reynolds, Joseph [1 ]
Roy, Jaydeep [1 ]
Short, Jonathan [1 ]
Uribe, Jorge [1 ]
Waters, William [1 ]
Yin, Zhye [1 ]
Zhang, Xi [1 ]
Zou, Yun [1 ]
Senzig, Bob [2 ]
Baek, Jongduk [3 ]
Pelc, Norbert [3 ]
机构
[1] GE Global Res, Niskayuna, NY 12309 USA
[2] GE Healthcare, Waukesha, WI 53188 USA
[3] Stanford Univ, Stanford, CA 94305 USA
关键词
D O I
10.1109/NSSMIC.2009.5401808
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Third-generation CT architectures are approaching fundamental limits. Dose-efficiency is limited by finite detector efficiency and by limited control over the X-ray flux spatial profile. Increasing the volumetric coverage comes with increased scattered radiation, cone-beam artifacts, Heel effect, wasted dose and cost. Spatial resolution is limited by focal spot size and detector cell size. Temporal resolution is limited by mechanical constraints, and alternative geometries such as electron-beam CT and dual-source CT come with severe tradeoffs in terms of image quality, dose-efficiency and complexity. The concept of multi-source inverse-geometry CT (IGCT) breaks through several of the above limitations [1-3], promising a low-dose high image quality volumetric CT architecture. In this paper, we present recent progress with the design and integration efforts of the first gantry-based multi-source CT scanner.
引用
收藏
页码:3531 / +
页数:2
相关论文
共 50 条
  • [1] Initial results with a multi-source inverse-geometry CT system
    Baek, Jongduk
    Pelc, Norbert J.
    Deman, Bruno
    Uribe, Jorge
    Harrison, Daniel
    Reynolds, Joseph
    Neculaes, Bogdan
    Inzinna, Louis
    Caiafa, Antonio
    [J]. MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [2] Multisource Inverse-Geometry CT Prototype System Integration
    Uribe, Jorge
    Reynolds, Joseph L.
    Inzinna, Louis P.
    Longtin, Randy
    Harrison, Daniel D.
    De Man, Bruno
    Neculaes, Bogdan
    Caiafa, Antonio
    Waters, William
    Frutschy, Kristopher J.
    Senzig, Robert
    Baek, Jongduk
    Pelc, Norbert
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2578 - 2581
  • [3] A multi-source inverse-geometry CT system: initial results with an 8 spot x-ray source array
    Baek, Jongduk
    De Man, Bruno
    Uribe, Jorge
    Longtin, Randy
    Harrison, Daniel
    Reynolds, Joseph
    Neculaes, Bogdan
    Frutschy, Kristopher
    Inzinna, Louis
    Caiafa, Antonio
    Senzig, Robert
    Pelc, Norbert J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (05): : 1189 - 1202
  • [4] A prototype table-top inverse-geometry volumetric CT system
    Schmidt, Taly Gilat
    Star-Lack, Josh
    Bennett, N. Robert
    Mazin, Samuel R.
    Solomon, Edward G.
    Fahrig, Rebecca
    Pelc, Norbert J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 1867 - 1878
  • [5] Data normalization method for a multi-source inverse geometry CT system
    Baek, Jongduk
    Pelc, Norbert J.
    [J]. MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [6] Multi-source inverse geometry CT :: a new system concept for X-ray computed tomography
    De Man, Bruno
    Basu, Samit
    Beque, Dirk
    Claus, Bernhard
    Edic, Pete
    Iatrou, Maria
    LeBlanc, James
    Senzig, Bob
    Thompson, Richard
    Vermilyea, Mark
    Wilson, Colin
    Yin, Zhye
    Pelc, Norbert
    [J]. MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [7] What is inverse-geometry CT?
    Schmidt, Taly Gilat
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (03) : 145 - 148
  • [8] MTF analysis of a prototype table-top inverse-geometry volumetric CT system
    Schmidt, TG
    Bennett, NR
    Mazin, SR
    Star-Lack, J
    Solomon, EG
    Pelc, NJ
    [J]. MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 171 - 178
  • [9] MULTI-SOURCE INVERSE GEOMETRY CT(MS-IGCT) SYSTEM : A NEW CONCEPT OF 3D CT IMAGING
    Choi, Shinkook
    Baek, Jongduk
    [J]. 2013 IEEE 11TH IVMSP WORKSHOP: 3D IMAGE/VIDEO TECHNOLOGIES AND APPLICATIONS (IVMSP 2013), 2013,
  • [10] A volumetric reconstruction algorithm for stationary source inverse-geometry CT
    Hsieh, Scott S.
    Pelc, Norbert J.
    [J]. MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313