Improving the passive survivability of residential buildings during extreme heat events in the Pacific Northwest

被引:17
|
作者
Rempel, Alexandra R. [1 ]
Danis, Jackson [2 ]
Rempel, Alan W. [3 ]
Fowler, Michael [4 ]
Mishra, Sandipan [5 ]
机构
[1] Univ Oregon, Environm Studies Program, Eugene, OR 97403 USA
[2] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
[3] Univ Oregon, Dept Earth Sci, Eugene, OR 97403 USA
[4] Mithun Inc, Seattle, WA 98101 USA
[5] Rensselaer Polytech Inst, Dept Mech Aerosp & Nucl Engn, Troy, NY 12180 USA
基金
美国国家科学基金会;
关键词
Shading control; Natural ventilation control; Cooling load reduction; Cool semi-arid climates; High desert climates; Climate-responsive design; NATURAL VENTILATION; CONTROL STRATEGIES; SHADING DEVICES; ENERGY; IMPACT; ISLAND; EFFICIENCY; BEHAVIOR; CLIMATE; SYSTEMS;
D O I
10.1016/j.apenergy.2022.119323
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Extreme heat events are becoming more frequent and more severe in the Pacific Northwest and in comparable dry-summer climates worldwide, increasing the occurrence of heat-related illness and death. Much of this risk is attributed to overheating in multifamily dwellings, particularly in neighborhoods with abundant asphalt, few trees, and limited financial resources. Air-conditioning expansion is problematic, however, because it creates vulnerability to operational costs and power outages, while expelled hot air intensifies urban heat island effects. In contrast, passive cooling strategies that deflect solar radiation and recruit the cool night air typical of Mediterranean, semi-arid, and arid climates are quite promising, but their abilities to improve residential survivability during extreme heat have not yet been explored. To understand this potential, here we investigate the extent to which well-controlled shading and natural ventilation, in some cases with fan assistance, could have diminished the hours in which indoor heat index levels exceeded 'caution', 'extreme caution', 'danger', and 'extreme danger' thresholds during the June 2021 heat wave in the Pacific Northwest; building thermal performance was simulated in EnergyPlus under conditions experienced by Vancouver BC, Seattle WA, Spokane WA, Portland OR, and Eugene OR. Strikingly, we find that in Portland, where the highest temperatures occurred, integrated shading and natural ventilation eliminated all hours above the danger threshold during the 3-day event, lowering peak indoor air temperatures by approximately 14 degrees C (25 degrees F); without cooling, all 72h exceeded this threshold. During the encompassing 10-day period, these passive measures provided 130-150h of thermal relief; baseline conditions without cooling provided none. Additionally, passive cooling reduced active cooling loads by up to 80%. Together, these results show the immediate, substantial value of requiring effective operable shading and secure operable windows in apartments in mild dry-summer climates with rising heatwave intensity, as well as public health messaging to support the productive operation of these elements.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Improving Regional Model Skills During Typhoon Events: A Case Study for Super Typhoon Lingling Over the Northwest Pacific Ocean
    Li, Delei
    Staneva, Joanna
    Bidlot, Jean-Raymond
    Grayek, Sebastian
    Zhu, Yuchao
    Yin, Baoshu
    FRONTIERS IN MARINE SCIENCE, 2021, 8
  • [22] Extreme Rainstorm Events over the Northwest Himalayas during 1875-2010
    Nandargi, S.
    Dhar, O. N.
    JOURNAL OF HYDROMETEOROLOGY, 2012, 13 (04) : 1383 - 1388
  • [23] Field demonstration of automated demand response for both winter and summer events in large buildings in the Pacific Northwest
    Piette, Mary Ann
    Kiliccote, Sila
    Dudley, Junqiao H.
    ENERGY EFFICIENCY, 2013, 6 (04) : 671 - 684
  • [24] Field demonstration of automated demand response for both winter and summer events in large buildings in the Pacific Northwest
    Mary Ann Piette
    Sila Kiliccote
    Junqiao H. Dudley
    Energy Efficiency, 2013, 6 : 671 - 684
  • [25] Residential greenness for mitigating impacts of extreme heat events on depression and supporting mental health
    Yang, Ying
    Zhang, Yixin
    Sheng, Shaojie
    FRONTIERS IN PUBLIC HEALTH, 2023, 11
  • [26] IMPROVING THE ENERGY EFFICIENCY OF RESIDENTIAL BUILDINGS BY USING A DRAIN WATER HEAT RECOVERY SYSTEM
    Gabor, Timea
    Dan, Viorel
    Badila, Iulian-Nicolae
    Tiuc, Ancuta-Elena
    Sur, Ioana Monica
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2017, 16 (07): : 1631 - 1636
  • [27] An empirical review of methods to assess overheating in buildings in the context of changes to extreme heat events
    Cole, Rebecca
    Evins, Ralph
    Eames, Matt
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2024, 17 (03) : 322 - 337
  • [28] Glomerular Filtration Rate Is Maintained During Extreme Passive Heat Exposure
    Hess, Hayden W.
    Hostler, David
    Johnson, Blair J.
    Pryor, Riana R.
    Chapman, Christopher L.
    Schlader, Zachary J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2021, 53 (08): : 347 - 347
  • [29] Toxic events in the Northwest Pacific coastline of Mexico during 1992–1995: origin and impact
    José Luís Ochoa
    Arturo Sánchez-Paz
    Ariel Cruz-Villacorta
    Erick Nunez-Vázquez
    Arturo Sierra-Beltrán
    Hydrobiologia, 1997, 352 : 195 - 200
  • [30] Effect of Climate Change and Extreme Weather Events on the Thermal Conditions of Canadian Multi-unit Residential Buildings
    Baba, Fuad Mutasim
    Ge, Hua
    ASHRAE TRANSACTIONS 2019, VOL 125, PT 2, 2019, 125 : 30 - 33