Pinch-off syndrome from a chemoport catheter successfully managed with endovascular retrieval

被引:1
|
作者
Chuah, Jun Sen [1 ,2 ]
Wong, Wei Li [3 ]
Bakin, Salinawati [3 ]
Lim, Raymond Zhun Ming [2 ]
Lee, Ee Peng [2 ]
Tan, Jih Huei [2 ]
机构
[1] Univ Kebangsaan Malaysia, Dept Gen Surg, Med Ctr, Kuala Lumpur 56000, Malaysia
[2] Hosp Sultanate Aminah, Dept Gen Surg, Minist Hlth Malaysia, Johor Baharu, Malaysia
[3] Hosp Sultanate Aminah, Dept Radiol, Minist Hlth Malaysia, Johor Baharu, Malaysia
来源
关键词
Pinch-off syndrome; Oncology; Interventional radiologist; Case report; COMPLICATION;
D O I
10.1016/j.amsu.2021.102294
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and importance: A totally implantable venous access device (TIVAD), also referred to as 'chemoport', is frequently used for oncology patients. Chemoport insertion via the subclavian vein access may compress the catheter between the first rib and the clavicle, resulting in pinch-off syndrome (POS). The sequela includes catheter transection and subsequent embolization. It is a rare complication with incidence reported to be 1.1-5.0% and can lead to a devastating outcomes. Case presentation: 50-year-old male had his chemoport inserted for adjuvant chemotherapy 3 years ago. During the removal, remaining half of the distal catheter was not found. There was no difficulties during the removal. Chest xray revealed that the fractured catheter had embolized to the right ventricle. Further history taking, he did experienced occasional palpitation and chest discomfort for the past six months. Electrocardiogram and cardiac enzymes were normal. Urgent removal of the fractured catheter via the percutaneous endovascular approach, under fluoroscopic guidance by an experience interventional radiologist was done. The procedure was successful without any complication. Patient made an uneventful recovery. He was discharged the following day, and was well during his 3rd month follow up. Conclusion: Early detection and preventive measures can be done to prevent pinch-off syndrome. Unrecognized POS can result in fatal complications such as cardiac arrhythmia and septic embolization. Retrieval via the percutaneous endovascular approach provide excellent outcome in the case of embolized fractured catheter.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Port-a-Cath (TM) partial rupture in a low-grade pinch-off syndrome
    Eizaga Rebollar, R.
    Garcia Palacios, M. V.
    Pernia Romero, A.
    Torres Morera, L. M.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2018, 65 (07): : 420 - 421
  • [42] Is ultrasound-guided central venous port placement effective to avoid pinch-off syndrome?
    Tamura, Akio
    Sone, Miyuki
    Ehara, Shigeru
    Kato, Kenichi
    Tanaka, Ryoichi
    Nakasato, Tatsuhiko
    Itabashi, Tetsuya
    JOURNAL OF VASCULAR ACCESS, 2014, 15 (04): : 311 - 316
  • [43] Pinch-off masses of very viscous fluids extruded from dies of arbitrary shape
    Tronnolone, Hayden
    Stokes, Yvonne M.
    PHYSICS OF FLUIDS, 2018, 30 (07)
  • [44] Recoil of a liquid filament: escape from pinch-off through creation of a vortex ring
    Hoepffner, Jerome
    Pare, Gounseti
    JOURNAL OF FLUID MECHANICS, 2013, 734 : 183 - 197
  • [45] Surgical treatment of pinch-off syndrome: A hybrid technique combining cone-beam computed tomography-guided targeting and surgical removal of catheter remnant
    Kim, Chang Hun
    Lee, Sung Kwnag
    Kim, Do Hyung
    JOURNAL OF PEDIATRIC SURGERY CASE REPORTS, 2020, 56
  • [46] Shape deformation and oscillation of particle-laden bubbles after pinch-off from a nozzle
    Wang, H.
    Brito-Parada, P. R.
    CHEMICAL ENGINEERING JOURNAL, 2021, 412
  • [47] Numerical Simulation for Liquid Dripping Flow Behavior from Filament Formation to Pinch-Off in Viscoelastic Fluids
    Yamamoto, Haruki
    Muto, Masakazu
    Tamano, Shinji
    NIHON REOROJI GAKKAISHI, 2024, 52 (03) : 181 - 191
  • [48] A delayed complication of a port-a-cath insertion via subclavian venous access: Case report of a "pinch-off syndrome"
    Caiazzo, Marco
    Golino, Ludovica
    Addeo, Raffaele
    Fardello, Francesco
    Russo, Gianmarco
    Imperatore, Francesco
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2022, 94
  • [49] Embolization of a PORT-A-CATH device in the main pulmonary artery and its percutaneous extraction in a patient with pinch-off syndrome
    Cilingiroglu, Mehmet
    Akkus, Nuri Ilker
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2012, 40 (02): : 162 - 164
  • [50] Microjet-Initiated Nano-Gaseous Layer Pinch-Off from the Surface of a Bubble and Subsequent Breakup
    Xiong, Sha
    Chin, Lip Ket
    Tandiono, T.
    Liu, Ai-Qun
    Ohl, Claus-Dieter
    ISRAEL JOURNAL OF CHEMISTRY, 2014, 54 (11-12) : 1602 - 1606