Ultrasound Frequency Analysis of a Magnetic Fluid in Low-Intensity External Magnetic Field

被引:0
|
作者
Kurimsky, J. [1 ]
Rajnak, M. [1 ,2 ]
Cimbala, R. [1 ]
Dolnik, B. [1 ]
Tothova, J. [1 ]
Paulovicova, K. [2 ]
Timko, M. [2 ]
Kopcansky, P. [2 ]
Kolcunova, I. [1 ]
Petras, J. A. [1 ]
Dzmura, J. [1 ]
Balogh, J. [1 ]
机构
[1] Tech Univ Kosice, Fac Elect Engn & Informat, Letna 9, Kosice 04154, Slovakia
[2] SAS, Inst Expt Phys, Watsonova 47, Kosice 04001, Slovakia
关键词
WAVELET ANALYSIS; TRANSFORMER OIL; FERROFLUIDS; NANOFLUIDS; VELOCITY;
D O I
10.12693/APhysPolA.131.910
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
This work deals with an interaction of a magnetic fluid of a dielectric nature with a magnetic field by means of ultrasound waves measurements and analysis. Ultrasound analysis is known as a non-destructive inspection tool often used in technical diagnostics, moreover, it has numerous applications in medicine and biology, too. We report the low-frequency ultrasound analysis of a dielectric magnetic fluid in a low-intensity external static magnetic field. The studied magnetic fluid was composed of a transformer oil and dispersed magnetite nanoparticles coated with oleic acid. Experiments were carried out by using an ultrasonic testing cell. The cell was exposed to a magnetic field of 50 mT in both parallel and perpendicular direction to the waves propagation. A through-transmission mode measurement was applied, where two fixed narrow-band transducers with completely shielded crystal for maximum RFI/EMI immunity (Physical Acoustic R15I-AST, the resonant frequency 150 kHz) served as a transmitter and a receiver. In this way we carried out the measurement of the frequency-dependent ultrasonic response to a rectangle calibrating signal of 5 mu s pulse width. Digitized signals were recorded for further analysis. We present the frequency domain analysis of the low-frequency ultrasound in magnetic fluid. The frequency spectrum in magnetic fluid colloidal system was calculated by the Fourier transformation method. Results show that there is a frequency shift in the amplitude-frequency spectrum caused by the step-up magnetic field. The higher the magnetic field, the higher the frequency of the peaks. The effect of particle aggregation in magnetic field on the ultrasound wave propagation is discussed in the paper.
引用
收藏
页码:910 / 912
页数:3
相关论文
共 50 条
  • [31] DNA packing by low-intensity ultrasound
    Park, D.
    Song, G.
    Park, H.
    Lee, M-H.
    Jang, J-Y.
    Kim, H-S.
    Kim, C-W.
    Seo, J.
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [32] Effects of External Magnetic Field on Intensity of Plasma Flow
    Ho, Ching-Yen
    Tsai, Yu-Hsiang
    Ma, Chuang
    ADVANCE MATERIALS DEVELOPMENT AND APPLIED MECHANICS, 2014, 597 : 272 - 275
  • [33] A study of the effect of an external magnetic field on the resonant frequency of magnetic fluids
    Fannin, PC
    Charles, SW
    Relihan, T
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1996, 162 (2-3) : 319 - 326
  • [34] Low-intensity pulsed ultrasound: Nonunions
    Dijkman, Bernadette G.
    Sprague, Sheila
    Bhandari, Mohit
    INDIAN JOURNAL OF ORTHOPAEDICS, 2009, 43 (02) : 141 - 148
  • [35] Low-frequency electromagnetic fluctuations in a plasma with strong external magnetic field
    Sitenko, AG
    Kharchenko, AV
    PLASMA PHYSICS AND CONTROLLED FUSION, 1999, 41 (03) : 399 - 414
  • [36] Remote Excitation of Neuronal Circuits Using Low-Intensity, Low-Frequency Ultrasound
    Tyler, William J.
    Tufail, Yusuf
    Finsterwald, Michael
    Tauchmann, Monica L.
    Olson, Emily J.
    Majestic, Cassondra
    PLOS ONE, 2008, 3 (10):
  • [37] Effect of low-frequency low-intensity ultrasound on contractile function of isolated heart
    Petrishchev, NN
    Vlasov, TA
    Galagudza, MM
    Makov, YN
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2002, 133 (04) : 327 - 329
  • [38] Effect of Low-Frequency Low-Intensity Ultrasound on Contractile Function of Isolated Heart
    N. N. Petrishchev
    T. D. Vlasov
    M. M. Galagudza
    Yu. N. Makov
    Bulletin of Experimental Biology and Medicine, 2002, 133 : 327 - 329
  • [39] Investigation of the magnetic separation performance of a low-intensity magnetic separator embedded with auxiliary permanent magnets
    Wang, Feiwang
    Zhang, Shitao
    Zhao, Zhiqiang
    Gao, Likun
    Tong, Xiong
    Dai, Huixin
    MINERALS ENGINEERING, 2022, 178
  • [40] High-frequency, low-intensity ultrasound and microbubbles enhance nerve blockade
    Cullion, Kathleen
    Santamaria, Claudia M.
    Zhan, Changyou
    Zurakowski, David
    Sun, Tao
    Pemberton, Grant L.
    McDannold, Nathan J.
    Kohane, Daniel S.
    JOURNAL OF CONTROLLED RELEASE, 2018, 276 : 150 - 156