Investigation on VOC Emissions from Automobile Sources by Means of Online Mass Spectrometry

被引:14
|
作者
Inomata, Satoshi [1 ]
Yamada, Hiroyuki [2 ]
Tanimoto, Hiroshi [1 ]
机构
[1] Natl Inst Environm Studies, 16-2 Onogawa, Tsukuba, Ibaraki 3058506, Japan
[2] Natl Traff Safety & Environm Lab, 7-42-27 Jindaiji Higashimachi, Chofu, Tokyo 1820012, Japan
来源
CURRENT POLLUTION REPORTS | 2016年 / 2卷 / 03期
关键词
Chemical ionization mass spectrometry; Proton transfer; Diesel exhaust; Nitro-organic compound; Evaporative emissions; Refueling emissions;
D O I
10.1007/s40726-016-0032-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study reviews recent research on volatile organic compound (VOC) emissions from motorized vehicle sources by means of online mass spectrometry. Chemical ionization is a powerful tool that usually permits soft ionization of chemical species and it allows the time-resolved measurement of multiple VOCs, even in complex samples where many kinds of VOCs coexist. The vehicular exhaust gasses are investigated using H3O+, NO+, Hg+, and CH3C(O)O- as a reagent ion in online chemical ionization mass spectrometry. The proton transfer using H3O+ as a reagent ion was used for the detection of nitro-organic compounds such as nitromethane and nitrophenol. The time-resolved measurement of the nitro-organic compounds in the laboratory experiments with a chassis dynamometer system revealed their emission properties, such as the dependence of the emissions as a function of vehicular velocity and acceleration/deceleration, as well as the effect of various types of exhaust gas treatment. The data regarding the nitromethane and nitrophenol emissions obtained in the field measurements were consistent with the results of the laboratory experiments done with a chassis dynamometer system. In the experiments involving evaporative emissions from gasoline-powered cars, NO+ was used as a reagent ion. Online measurements showed that the adsorption of hydrocarbons in a sealed housing evaporative determination unit could result in emissions being underestimated, if the concentrations are monitored only before and after a diurnal breathing loss test. The composition analysis gave an estimated ozone formation potential (OFP) approximately 20 % higher for breakthrough emissions and refueling emissions than for the gasoline that was tested, but the OFP for the permeation emissions was almost the same as the OFP for the test fuel.
引用
收藏
页码:188 / 199
页数:12
相关论文
共 50 条
  • [31] INVESTIGATION OF GAS-SOLID REACTIONS BY MEANS OF THERMAL-ANALYSIS MASS-SPECTROMETRY
    JAENICKEROSSLER, K
    LEITNER, G
    MULLER, F
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (1-3): : 170 - 171
  • [32] INVESTIGATION OF COMPOSITION AND STRUCTURE OF PETROLEUM SULFIDES BY MEANS OF HIGH-RESOLUTION MASS-SPECTROMETRY
    POLYAKOVA, AA
    VASILENKO, GV
    KOGAN, LO
    CHEMISTRY AND TECHNOLOGY OF FUELS AND OILS, 1978, 14 (9-10) : 696 - 698
  • [33] Mass spectral characterization of aerosol emissions from South Asian combustion sources
    Goetz, James
    Giordano, Michael
    Stockwell, Chelsea
    Christian, T. J.
    Bhave, Prakash
    Praveen, P. S.
    Panday, Arnico
    Jayarathne, Thilina
    Stone, Elizabeth
    Yokelson, Robert
    DeCarlo, Peter
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [34] Imaging VOC distribution and tracing emission sources in surface water by a mobile shipborne spray inlet proton transfer reaction mass spectrometry
    Liang, Qu
    Ma, Zhaoyun
    Bao, Xun
    Xu, Wei
    Zhang, Qiangling
    Zou, Xue
    Shen, Chengyin
    Chu, Yannan
    JOURNAL OF CLEANER PRODUCTION, 2023, 414
  • [35] A simple method to determine VOC emissions from constant emission sources and its application in indoor air quality studies
    Zhu, JP
    Cao, XL
    INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 204 - 209
  • [36] Online Electrochemistry/Electrospray Mass Spectrometry with a Coaxial Probe for Investigation of Electrochemical Derivatization of Anthracene with Dodecylamine
    Ling Xing
    Ding Chuan-Fan
    ACTA PHYSICO-CHIMICA SINICA, 2012, 28 (11) : 2616 - 2624
  • [37] Online Investigation of Aqueous-Phase Electrochemical Reactions by Desorption Electrospray Ionization Mass Spectrometry
    Lu, Mei
    Liu, Yong
    Helmy, Roy
    Martin, Gary E.
    Dewald, Howard D.
    Chen, Hao
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (10) : 1676 - 1685
  • [38] Investigation on emissions of volatile and semi volatile compounds (VOC, SVOC), dust and ozone from electronic consumer products
    Kemmlein, S
    Rockstroh, J
    Jann, O
    Electronics Goes Green 2004 (Plus): Driving Forces for Future Electronics, Proceedings, 2004, : 1051 - 1052
  • [40] Differentiation of strains of Mycoplasma fermentans from various sources by pyrolysis mass spectrometry
    Hannan, PCT
    Kearns, AM
    Sisson, PR
    Freeman, R
    JOURNAL OF MEDICAL MICROBIOLOGY, 1997, 46 (04) : 348 - 353