Improving light collection efficiency using partitioned light guide on pixelated scintillator-based γ-ray imager

被引:3
|
作者
Hyeon, Suyeon [1 ]
Hammig, Mark [2 ]
Jeong, Manhee [1 ]
机构
[1] Jeju Natl Univ, Dept Nucl & Energy Engn, Jeju 63243, South Korea
[2] Univ Michigan, Dept Nucl Engn & Rad Sci, Ann Arbor, MI 48109 USA
关键词
Light collectionefficiency; Light guide; SiPM array; Scintillator array; Coded-aperture; CARTOGAM; CAMERA;
D O I
10.1016/j.net.2021.12.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
When gamma-camera sensor modules, which are key components of radiation imagers, are derived from the coupling between scintillators and photosensors, the light collection efficiency is an important factor in determining the effectiveness with which the instrument can identify nuclides via their derived gamma-ray spectra. If the pixel area of the scintillator is larger than the pixel area of the photosensor, light loss and cross-talk between pixels of the photosensor can result in information loss, thereby degrading the precision of the energy estimate and the accuracy of the position-of-interaction deter-mination derived from each active pixel in a coded-aperture based gamma camera. Here we present two methods to overcome the information loss associated with the loss of photons created by scintillation pixels that are coupled to an associated silicon photomultiplier pixel. Specifically, we detail the use of either: (1) light guides, or (2) scintillation pixel areas that match the area of the SiPM pixel. Compared with scintillator/SiPM couplings that have slightly mismatched intercept areas, the experimental results show that both methods substantially improve both the energy and spatial resolution by increasing light collection efficiency, but in terms of the image sensitivity and image quality, only slight improvements are accrued. (c) 2021 Korean Nuclear Society, Published by Elsevier Korea LLC. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1760 / 1768
页数:9
相关论文
共 50 条
  • [1] Light collection optimization in scintillator-based gamma-ray spectrometers
    Hull, G.
    Du, S.
    Niedermayr, T.
    Payne, S.
    Cherepy, N.
    Drobshoff, A.
    Fabris, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 588 (03): : 384 - 388
  • [2] Simulation study of the light collection efficiency and the dependency on position resolution in plastic scintillator-based muography detectors
    Wang, Z.
    Pan, Z. W.
    Chen, Z.
    He, Z. Y.
    Lin, Z. B.
    Yang, T. Y.
    Yuan, Y.
    Wang, Y.
    Zhang, Z. Y.
    Xie, F.
    Liu, J. D.
    Liu, S. B.
    Ye, B. J.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (10)
  • [3] Development of a prototype scintillator-based portable γ-ray imager with coded aperture for intraoperative applications
    Shimazoe, K.
    Horiki, K.
    Takahashi, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 784 : 394 - 397
  • [4] Ultrafast inorganic scintillator-based front imager for Gigahertz Hard X-ray imaging
    Hu, Chen
    Zhang, Liyuan
    Zhu, Ren-Yuan
    Demarteau, Marcel
    Wagner, Robert
    Xia, Lei
    Xie, Junqi
    Li, Xuan
    Wang, Zhehui
    Shih, Yanhua
    Smith, Thomas
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 940 : 223 - 229
  • [5] Scintillator-Based Nanosecond Light Sources for Time-Resolved Fluorimetry
    Hobbs, Steven E.
    Hieftje, Gary M.
    Applied Spectroscopy, 1995, 49 (01): : 15 - 19
  • [6] Scintillator-based nanosecond light sources for time-resolved fluorimetry
    Hobbs, Steven E.
    Hieftje, Gary M.
    Applied Spectroscopy, 1995, 49 (01)
  • [7] Ultra-Broad Emission Copper Halide Scintillator-Based X-Ray Imager
    Lv, Haocheng
    Shao, Wenyi
    Chen, Haifeng
    Zhu, Guoyang
    Wang, Yao
    Zhang, Zhenzhong
    Liang, Hongwei
    ADVANCED SCIENCE, 2025, 12 (04)
  • [8] SCINTILLATOR-BASED NANOSECOND LIGHT-SOURCES FOR TIME-RESOLVED FLUOROMETRY
    HOBBS, SE
    HIEFTJE, GM
    APPLIED SPECTROSCOPY, 1995, 49 (01) : 15 - 19
  • [9] Improvement of photon collection uniformity from an NE213 scintillator using a light guide
    Harano, H
    Matsumoto, T
    Shibata, Y
    Ito, Y
    Uritani, A
    Kudo, K
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 841 - 845
  • [10] Improvement of photon collection uniformity from an NE213 scintillator using a light guide
    Harano, H
    Matsumoto, T
    Shibata, Y
    Ito, Y
    Uritani, A
    Kudo, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (06) : 3147 - 3150