We have investigated a new pulsed light source for time-resolved fluorimetry. The light source consists of a beta emitter, Sr-90, and a liquid or plastic scintillator. Time-correlated single photon counting is employed to demonstrate the new pulsed light source. Measured fluorescence lifetimes of standards anthracene(4.97 +/- 0.06 ns) and 1-aminoanthracene (21.4 +/- 0.2 ns) agree well with literature values. Advantages of the new light source include the low cost, the size (1 cm(-3) or smaller), the nanosecond pulse widths, the high pulse rates, and the extremely stable pulse-to-pulse profile. There is no risk of radioactive contamination from the beta emitter since it is bound in a ceramic matrix and encapsulated.
引用
收藏
页码:15 / 19
页数:5
相关论文
共 50 条
  • [1] Scintillator-based nanosecond light sources for time-resolved fluorimetry
    Hobbs, Steven E.
    Hieftje, Gary M.
    [J]. Applied Spectroscopy, 1995, 49 (01)
  • [2] Scintillator-Based Nanosecond Light Sources for Time-Resolved Fluorimetry
    Hobbs, Steven E.
    Hieftje, Gary M.
    [J]. Applied Spectroscopy, 1995, 49 (01): : 15 - 19
  • [3] POLARIZED NANOSECOND TIME-RESOLVED FLUOROMETRY
    DALE, RE
    [J]. JOURNAL OF LUMINESCENCE, 1979, 18-9 (JAN) : 120 - 126
  • [4] A high-Z inorganic scintillator-based detector for time-resolved in vivo dosimetry during brachytherapy
    Jorgensen, Erik B.
    Johansen, Jacob G.
    Overgaard, Joakim
    Piche-Meunier, Dominique
    Tho, Daline
    Rosales, Haydee M. L.
    Tanderup, Kari
    Beaulieu, Luc
    Kertzscher, Gustavo
    Beddar, Sam
    [J]. MEDICAL PHYSICS, 2021, 48 (11) : 7382 - 7398
  • [5] TIME-RESOLVED FLUOROMETRY OF BACTERIORHODOPSIN
    SHERMAN, WV
    [J]. PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1982, 36 (04) : 463 - 469
  • [6] TIME-RESOLVED FLUOROMETRY IN WATER ANALYSIS
    RESCH, U
    RURACK, K
    SENONER, M
    [J]. NACHRICHTEN AUS CHEMIE TECHNIK UND LABORATORIUM, 1994, 42 (05): : 504 - 506
  • [7] Signal amplification in time-resolved fluorometry
    Diamandis, EP
    [J]. CLINICAL CHEMISTRY, 2001, 47 (03) : 380 - 381
  • [8] Time-resolved fluorometry in bioanalytical assays
    Hurskainen, P
    Ollikka, P
    Karvinen, J
    Hemmilä, I
    [J]. CHIMICA OGGI-CHEMISTRY TODAY, 2001, 19 (05) : 22 - 24
  • [9] Evaluating scintillator performance in time-resolved hard X-ray studies at synchrotron light sources
    Rutherford, Michael E.
    Chapman, David J.
    White, Thomas G.
    Drakopoulos, Michael
    Rack, Alexander
    Eakins, Daniel E.
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 685 - 693
  • [10] NANOSECOND TIME-RESOLVED CRYSTALLOGRAPHY
    Moffat, Keith
    [J]. ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1999, 55 : 7 - 7