Current Prediction Fault-Tolerant Control for the Open-Winding PMSG System

被引:0
|
作者
Zhang, Xiaoguang [1 ]
Li, Yi
Zhang, Yongchang
机构
[1] North China Univ Technol, Inverter Technol Engn Res Ctr Beijing, Beijing, Peoples R China
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
Fault-tolerant; current prediction; open-circuit; OW-PMSG; dual H-bridge inverter;
D O I
10.1109/precede.2019.8753349
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper a fault-tolerant control strategy based on current prediction under open-circuit fault for the open-winding PMSG system is proposed. When the switch of one inverter is open-circuited, or one phase winding of the motor is open, the OW-PMSG system can be reconstructed as a two-phase operation system which is driven by dual H-bridge inverter. To keep the electromagnetic torque constant and the system operating steadily, the amplitude and phase of the remaining two-phase current need to be redesigned. The current-error-based cost function includes two-phase current error is designed to evaluate all voltage vectors produced by dual H-bridge inverter. Finally, simulations and experimental results are carried out to validate the proposed method.
引用
收藏
页码:169 / 172
页数:4
相关论文
共 50 条
  • [11] Fault-tolerant control strategy of open-winding brushless doubly fed wind power generator based on direct power control
    Jin, Shi
    Shi, Long
    Zhang, Yue
    Sun, Dan
    Ji, Bing
    [J]. IET ELECTRIC POWER APPLICATIONS, 2021, 15 (07) : 799 - 810
  • [12] Double Vector Model Predictive Current Control for the Semi-controlled Open-winding PMSG Generation System
    Zhang, Xiaoguang
    Zhang, Wenhan
    Wang, Keqin
    [J]. 2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 2595 - 2599
  • [13] Direct power control strategy with fault-tolerant for open-winding brushless doubly-fed wind power generator
    Zhu, Liancheng
    Xiao, Yang
    Jin, Shi
    Chen, Xiaohong
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2024, 44 (05): : 73 - 78
  • [14] Fault-tolerant Reconfiguration Control for the Open-winding Five-phase Inverter under Semi-controlled Condition
    Gong, Shang
    Liu, Zicheng
    Jiang, Dong
    Kong, Wubin
    Qu, Ronghai
    [J]. 2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 285 - 288
  • [15] A Novel Model Predictive Current Control Method for Open-Winding PMSG Fed by Dual Inverter
    Zhang, Xiaoguang
    Li, Yi
    He, Yikang
    [J]. 2018 21ST INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2018, : 1450 - 1454
  • [16] A New Zero-Sequence Current Suppression Control Strategy for Five-Phase Open-Winding Fault-Tolerant Fractional-Slot Concentrated Winding IPM Motor Driving System
    Cui, Ronghua
    Fan, Ying
    Cheng, Ming
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (03) : 2731 - 2740
  • [17] Fault-tolerant control of an open-winding brushless doubly-fed wind power generator system with dual three-level converter
    Shi Jin
    Long Shi
    Sul Ademi
    Yue Zhang
    Fengge Zhang
    [J]. Frontiers in Energy, 2023, 17 : 149 - 164
  • [18] Fault-tolerant control of an open-winding brushless doubly-fed wind power generator system with dual three-level converter
    Jin, Shi
    Shi, Long
    Ademi, Sul
    Zhang, Yue
    Zhang, Fengge
    [J]. FRONTIERS IN ENERGY, 2022, 17 (01) : 149 - 164
  • [19] A Parameter Robust Fault-Tolerant Control Scheme for Open-Winding Permanent Magnet Synchronous Motors in Flux-Weakening Regions
    Dong, Yuelin
    Zhang, Shuo
    Zhang, Chengning
    Wang, Shulin
    [J]. IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2024, 12 (04) : 4191 - 4203
  • [20] Switch Short-Circuit Fault-Tolerant Control of Five-Phase Open-Winding Motor Drive With a Floating Capacitor
    Sun, Xiangwen
    Liu, Zicheng
    Jiang, Dong
    Li, An
    Wang, Pengye
    Qu, Ronghai
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (11) : 10935 - 10945