Quantification of Trace Arsenic in Whole Blood by ICP-QMS/QMS

被引:0
|
作者
Shirataki, Junko [1 ]
Fujisaki, Kazuyuki [1 ]
Sakaguchi, Kouichi [1 ]
Sato, Nobuyuki [1 ]
机构
[1] Toray Res Ctr Ltd, Inorgan Anal Labs, 3-3-7 Sonoyama, Otsu, Shiga 5208567, Japan
关键词
Arsenic; whole blood; ICP-QMS/QMS; mass-shift; MS;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
ICP-QMS/QMS was applied to whole blood samples to determine the quantity of trace As. It was found that Fe also causes polyatomic interference with As in conventional ICP-QMS, in addition to Ca and Cl, and ICP-QMS/QMS can remove these interferences in mass-shift mode using O-2 as reaction gas. The ICP-QMS/QMS technique allows the determination of As at sub-ng mL(-1) levels.
引用
收藏
页码:735 / 738
页数:4
相关论文
共 50 条
  • [21] Fast and low sample consuming quantification of manganese in cell nutrient solutions by flow injection ICP-QMS
    Wehe, Christoph Alexander
    Bornhorst, Julia
    Holtkamp, Michael
    Sperling, Michael
    Galla, Hans-Joachim
    Schwerdtle, Tanja
    Karst, Uwe
    METALLOMICS, 2011, 3 (12) : 1291 - 1296
  • [22] Using ICP-qMS to trace the uptake of nanoscale titanium dioxide by microalgae–potential disadvantages of vegetable reference material
    Theodoros Potouridis
    Johannes Völker
    Heiko Alsenz
    Matthias Oetken
    Wilhelm Püttmann
    Analytical and Bioanalytical Chemistry, 2014, 406 : 2495 - 2502
  • [23] Application of internal standardization in ICP-QMS through discrete sample introduction methodologies
    Stefanova, V. (stefanova@argon.acad.bg), 1600, Royal Society of Chemistry (18):
  • [24] Application of internal standardization in ICP-QMS through discrete sample introduction methodologies
    Stefanova, V
    Kmetov, V
    Canals, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (09) : 1171 - 1174
  • [25] Detection of PTFE microparticles by ICP-qMS operated in single-particle mode
    Gelman, Faina
    Muszynska, Magdalena
    Karasinski, Jakub
    Lev, Ovadia
    Halicz, Ludwik
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (11) : 2282 - 2285
  • [26] Using ICP-qMS to trace the uptake of nanoscale titanium dioxide by microalgae-potential disadvantages of vegetable reference material
    Potouridis, Theodoros
    Voelker, Johannes
    Alsenz, Heiko
    Oetken, Matthias
    Puettmann, Wilhelm
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (11) : 2495 - 2502
  • [27] Development and validation of an analytical method for the determination of lead isotopic composition using ICP-QMS
    Rodriguez-Salazar, M. T.
    Morton Bermea, O.
    Hernandez-Alvarez, E.
    Garcia-Arreola, M. E.
    Ortuno-Arzate, M. T.
    GEOFISICA INTERNACIONAL, 2010, 49 (03): : 113 - 117
  • [28] Accurate quantification of mercury in river water by isotope dilution MC-ICP-SFMS and ICP-QMS detection after cold vapour generation
    Fischer, Lisa
    Brunner, Marion
    Prohaska, Thomas
    Hann, Stephan
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (11) : 1983 - 1991
  • [29] Arsenic determination by ICP-QMS with octopole collision/reaction cell. Overcome of matrix effects under vented and pressurized cell conditions
    Colon, Mireia
    Hidalgo, Manuela
    Iglesias, Monica
    TALANTA, 2011, 85 (04) : 1941 - 1947
  • [30] Investigating the Influence of Non-Spectral Matrix Effects in the Determination of Twenty-Two Trace Elements in Rock Samples by ICP-QMS
    Yokoyama, Tetsuya
    Nagai, Yuichiro
    Hinohara, Yu
    Mori, Tomohiko