Active Suppression Method of Dangerous Behaviors for Robot-Assisted Vascular Interventional Surgery

被引:18
|
作者
Jin, Xiaoliang [1 ,2 ]
Guo, Shuxiang [1 ,3 ]
Guo, Jian [4 ]
Shi, Peng [1 ,2 ]
Kawanishi, Masahiko [5 ]
Hirata, Hideyuki [6 ]
机构
[1] Beijing Inst Technol, Key Lab Convergence Med Engn Syst & Healthcare Te, Minist Ind & Informat Technol, Beijing 100081, Peoples R China
[2] Kagawa Univ, Grad Sch Engn, Takamatsu, Kagawa 7610396, Japan
[3] Kagawa Univ, Dept Intelligent Mech Syst Engn, Fac Engn & Design, Takamatsu, Kagawa 7610396, Japan
[4] Tianjin Univ Technol, Tianjin Key Lab Controlory & Applicat Complicated, Tianjin 300384, Peoples R China
[5] Kagawa Univ, Dept Neurol Surg, Fac Med, Takamatsu, Kagawa 7610793, Japan
[6] Kagawa Univ, Dept Intelligent Mech Syst Engn, Takamatsu, Kagawa 7610396, Japan
基金
日本学术振兴会; 中国国家自然科学基金;
关键词
Medical services; Force; Catheters; Robots; Manipulators; Safety; Surgery; Active enhancing safety method; active suppression method; collision force; flexible instruments; haptic force feedback; robot-assisted vascular interventional surgery (VIS); GUIDEWIRE; CATHETER; FRAMEWORK; FEEDBACK; SYSTEM;
D O I
10.1109/TIM.2022.3170997
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The procedure of vascular interventional surgery (VIS) is very complicated. It requires doctors to wear the protecting suits and manipulate the flexible instruments (catheters and guidewires) for a long time to complete the treatment, which may fatigue the doctors and lead to misoperation. Besides, the X-ray radiation in the operating room is also bad for doctors' health. So, to solve the above challenges, a novel robot-assisted system was developed for VIS, which realizes the separation of the doctor and the operating room; a preliminary method was used on the slave side to reduce the excessive collision force when the tip of the catheter travels through the curved blood vessel, and the active enhancing safety method of the robot-assisted system was proposed to reduce the danger caused by doctors' misoperation (dangerous behaviors) during the surgery. Finally, to verify the proposed methods, a series of experiments in vitro were conducted, and experimental results indicated that the method of assisting the deflection of the tip of the catheter has the potential to reduce the excessive collision force, the collision force at the tip of the catheter was reduced by 0.104 N when a misoperation occurred during the operation procedure under the condition of the active enhancing safety method, and the stronger sense of the tactile presence was generated by the master manipulator when the total force of the slave side was greater than 1.0 N. Therefore, based on the above results, we believe that the proposed methods are effective.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Development of a Tactile Sensing Robot-Assisted System for Vascular Interventional Surgery
    Jin, Xiaoliang
    Guo, Shuxiang
    Guo, Jian
    Shi, Peng
    Tamiya, Takashi
    Hirata, Hideyuki
    [J]. IEEE SENSORS JOURNAL, 2021, 21 (10) : 12284 - 12294
  • [2] Safety Protection Based on Electromagnetic Navigation in Robot-assisted Vascular Interventional Surgery
    Tao, Li
    Xie, Hongzhi
    Zhang, Shuyang
    Gu, Lixu
    [J]. 2017 10TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI), 2017,
  • [3] Robot-assisted techniques in vascular and endovascular surgery
    Pueschel, A.
    Schafmayer, C.
    Gross, J.
    [J]. LANGENBECKS ARCHIVES OF SURGERY, 2022, 407 (05) : 1789 - 1795
  • [4] Robot-Assisted Vascular Surgery, 250 Cases
    Stadler, Petr
    Dvoracek, Libor
    Vitasek, Petr
    Matous, Pavel
    [J]. JOURNAL OF VASCULAR SURGERY, 2013, 57 (01) : 292 - 292
  • [5] Robot-assisted techniques in vascular and endovascular surgery
    A. Püschel
    C. Schafmayer
    J. Groß
    [J]. Langenbeck's Archives of Surgery, 2022, 407 : 1789 - 1795
  • [6] Multi-mode information fusion navigation system for robot-assisted vascular interventional surgery
    Guan, Shaoya
    Li, Tianqi
    Meng, Cai
    Ma, Limei
    [J]. BMC SURGERY, 2023, 23 (01)
  • [7] Multi-mode information fusion navigation system for robot-assisted vascular interventional surgery
    Shaoya Guan
    Tianqi Li
    Cai Meng
    Limei Ma
    [J]. BMC Surgery, 23
  • [8] Kinematic Analysis of the Catheter used in the Robot-assisted Catheter Operating System for Vascular Interventional Surgery
    Guo, Shuxiang
    Du, Wenxuan
    Guo, Jian
    Yu, Yang
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2016, : 1233 - 1238
  • [9] A Teleoperation Control Method for Vascular Interventional Surgery Robot
    Yuan, Hang
    Xiao, Nan
    Cheng, Mengqi
    Wang, Kaidi
    [J]. 2021 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2021), 2021, : 1027 - 1032
  • [10] Suture damage during robot-assisted vascular surgery: Is it an issue?
    Diks, Jeroen
    Nio, Denise
    Linsen, Matteus A.
    Rauiverda, Jan A.
    Wisselink, Willem
    [J]. SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2007, 17 (06): : 524 - 527