Impact of assay format on miRNA sensing: Electrochemical microfluidic biosensor for miRNA-197 detection

被引:51
|
作者
Kutluk, Hazal [1 ]
Bruch, Richard [1 ,2 ]
Urban, Gerald A. [1 ,3 ]
Dincer, Can [1 ,2 ]
机构
[1] Univ Freiburg, Dept Microsyst Engn, Freiburg, Germany
[2] Univ Freiburg, Freiburg Ctr Interact Mat & Bioinspired Technol, Georges Kohler Allee 105,Room 02-028, D-79110 Freiburg, Germany
[3] Freiburg Mat Res Ctr, Freiburg, Germany
来源
关键词
microRNA analysis; Competitive assay; Sandwich assay; Electrochemical biosensors; Microfluidics; Point-of-care testing; MICRORNA BIOSENSORS; CANCER; VALIDATION; BIOMARKERS; DEVICES; TRENDS;
D O I
10.1016/j.bios.2019.111824
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
MicroRNAs (miRNAs) are important biomarkers for the early detection of various diseases, especially cancer. Therefore, there is a continuing interest in different biosensing strategies that allow for the point-of-care measurement of miRNAs. Almost all miRNA sensors utilize cross-hybridization of the target miRNA with a capture probe for the recognition, which can be designed in either a sandwich or a competitive format. In this work, we present a low-cost microfluidic biosensor platform for the electrochemical measurement of miRNA-197 (a tumor biomarker candidate) in undiluted human serum samples, operating with very low sample volumes (580 nl) and a sample-to-result time of one hour. For this purpose, different on-chip miRNA bioassays based on sandwich and competitive formats are developed and compared in terms of their sensitivity, dynamic range, selectivity, precision, and simplicity. The obtained results show that, despite having a narrower dynamic range when compared to the competitive format, the sandwich assay has superior performance regarding its sensitivity and selectivity. The lowest limit of detection which can be achieved with the sandwich assay is 1.28 nM (0.74 fmole), while 4.05 nM (2.35 fmole) with the competitive format. Moreover, the sandwich assay proves to have a better distinction against single-base mismatch oligonucleotide sequences compared to the competitive one. Due to its versatility and easy handling, overcoming the issue with the sensitivity, the implemented electrochemical microfluidic biosensor could pave the way for rapid and low-cost on-site miRNA diagnostics.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] DEVELOPMENT OF A MIRNA ASSAY FOR PROSTATE CANCER DETECTION
    Larne, O. S.
    Edsjo, A.
    Bjartell, A.
    Ceder, A. Y.
    EUROPEAN UROLOGY SUPPLEMENTS, 2009, 8 (04) : 316 - 316
  • [22] Recent Development of the Electrochemical Sensors for miRNA Detection
    Xie, Xianjin
    Liu, Jinyao
    Ding, Mengkui
    Yang, Xiaoyu
    Peng, Yaru
    Zhao, Yuefeng
    Ouyang, Ruizhuo
    Miao, Yuqing
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (04): : 01 - 17
  • [23] CRISPR/Cas13a-Powered Electrochemical Microfluidic Biosensor for Nucleic Acid Amplification-Free miRNA Diagnostics
    Bruch, Richard
    Baaske, Julia
    Chatelle, Claire
    Meirich, Mailin
    Madlener, Sibylle
    Weber, Wilfried
    Dincer, Can
    Urban, Gerald Anton
    ADVANCED MATERIALS, 2019, 31 (51)
  • [24] Electrochemical biosensor for CRISPR/Cas13a powered miRNA diagnostics
    Bruch, Richard
    Baaske, Julia
    Chatelle, Claire
    Weber, Wilfried
    Dincer, Can
    Urban, Gerald
    2019 IEEE SENSORS, 2019,
  • [25] Laser induced self-N-doped porous graphene as an electrochemical biosensor for femtomolar miRNA detection
    Wan, Zhengfen
    Umer, Muhammad
    Lobino, Mirko
    Thiel, David
    Nam-Trung Nguyen
    Trinchi, Adrian
    Shiddiky, Muhammad J. A.
    Gao, Yongsheng
    Li, Qin
    CARBON, 2020, 163 : 385 - 394
  • [26] Highly sensitive antimonene based SPR biosensor for miRNA detection
    Singh, Maneesh Kumar
    Pal, Sarika
    Prajapati, Y. K.
    Saini, J. P.
    MATERIALS TODAY-PROCEEDINGS, 2020, 28 : 1776 - 1780
  • [27] Switch-conversional ratiometric fluorescence biosensor for miRNA detection
    Chen, Xian
    Xu, Ke
    Li, Jing
    Yang, Ming
    Li, Xing
    Chen, Qin
    Lu, Chunhua
    Yang, Huanghao
    BIOSENSORS & BIOELECTRONICS, 2020, 155
  • [28] DNA Walking and Rolling Nanomachine for Electrochemical Detection of miRNA
    Miao, Peng
    Tang, Yuguo
    SMALL, 2020, 16 (47)
  • [29] Simultaneous detection of ovarian cancer related miRNA biomarkers with carboxylated graphene oxide modified electrochemical biosensor platform
    Kivrak, Ezgi
    Kara, Pinar
    BIOELECTROCHEMISTRY, 2025, 161
  • [30] Carbon nanotube-based label-free electrochemical biosensor for sensitive detection of miRNA-24
    Li, Fengye
    Peng, Jing
    Wang, Jingjing
    Tang, Hao
    Tan, Liang
    Xie, Qingji
    Yao, Shouzhuo
    BIOSENSORS & BIOELECTRONICS, 2014, 54 : 158 - 164