The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation

被引:88
|
作者
Jazrawi, LM [1 ]
Birdzell, L [1 ]
Kummer, FJ [1 ]
Di Cesare, PE [1 ]
机构
[1] NYU, Hosp Joint Dis, Musculoskeletal Res Ctr, Dept Orthopaed Surg, New York, NY 10003 USA
来源
JOURNAL OF ARTHROPLASTY | 2000年 / 15卷 / 06期
关键词
computed tomography; knee; retation; arthroplasty;
D O I
10.1054/arth.2000.8193
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patellofemoral complications, instability, and tibial polyethylene wear after total knee arthroplasty (TKA) resulting from malrotation of the tibial or femoral components (or both) may be difficult to diagnose based on physical examination and standard knee radiographs. The preoperative assessment of implant rotational alignment is critical in planning treatment because the femoral or tibial component (or both) may need to be revised if malpositioned. The purpose of this study was to ascertain the accuracy of computed tomography (CT) scan for determining rotational alignment of femoral and tibial components in TKA. TKA components were inserted in human cadaver specimens at neutral and 5 degrees of external or internal rotation. For each position, the amount of rotation, determined from digital photographs, was compared with CT scan. The correlation coefficient between these two values averaged 0.87, which was significant at P < .05. The CT scan protocol described in this study can be applied clinically to patients with patellofemoral complaints to confirm or rule out the presence of component malrotation.
引用
收藏
页码:761 / 766
页数:6
相关论文
共 50 条
  • [31] Combined femoral and tibial component total knee arthroplasty device rotation measurement is reliable and predicts clinical outcome
    Hernandez-Hermoso, Jose A.
    Nescolarde, Lexa
    Yanez-Siller, Federico
    Calle-Garcia, Juan
    Garcia-Perdomo, Damian
    Perez-Andres, Ricard
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2023, 24 (01)
  • [32] Isolated Femoral or Tibial Component Revision in Total Knee Arthroplasty:A Systematic Review
    Maestri, Marco
    Castagnini, Francesco
    Giardina, Federico
    Tella, Giuseppe
    Tassinari, Enrico
    Traina, Francesco
    MEDICAL PRINCIPLES AND PRACTICE, 2023, 32 (4-5) : 225 - 231
  • [33] Computed tomography is not necessary to assess rotation of the femoral component in navigation-assisted total knee replacement
    Hernandez-Vaquero, Daniel
    Noriega-Fernandez, Alfonso
    Perez-Coto, Ivan
    Sandoval Garcia, Manuel A.
    Sierra-Pereira, Andres A.
    Roncero-Gonzalez, Sergio
    Manuel Fernandez-Carreira, Jose
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2016, 44 (06) : 1314 - 1322
  • [34] Accuracy and Validity of Sharma’s Venn Diagram Method for Assessment of Tibial Component Rotation in Total Knee Arthroplasty
    Mrinal Sharma
    Bharat Dhanjani
    Akshay Raj Upadhyaya
    Indian Journal of Orthopaedics, 2022, 56 : 1291 - 1302
  • [35] Accuracy and Validity of Sharma's Venn Diagram Method for Assessment of Tibial Component Rotation in Total Knee Arthroplasty
    Sharma, Mrinal
    Dhanjani, Bharat
    Upadhyaya, Akshay Raj
    INDIAN JOURNAL OF ORTHOPAEDICS, 2022, 56 (07) : 1291 - 1302
  • [36] Correlation of tibial component size and rotation with outcomes after total knee arthroplasty
    Antonio Klasan
    Joshua G. Twiggs
    Brett A. Fritsch
    Brad P. Miles
    Thomas J. Heyse
    Michael Solomon
    David A. Parker
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1819 - 1824
  • [37] Reliability of frames of reference used for tibial component rotation in total knee arthroplasty
    Page, Stephen R.
    Deakin, Angela H.
    Payne, Anthony P.
    Picard, Frederic
    COMPUTER AIDED SURGERY, 2011, 16 (02) : 86 - 92
  • [38] A new landmark for measuring tibial component rotation after total knee arthroplasty
    Mahmood, Fand F.
    Holloway, Nicholas J.
    Deakin, Angela H.
    Clarke, Jon V.
    Picard, Frederic
    KNEE, 2019, 26 (03): : 779 - 786
  • [39] Correlation of tibial component size and rotation with outcomes after total knee arthroplasty
    Klasan, Antonio
    Twiggs, Joshua G.
    Fritsch, Brett A.
    Miles, Brad P.
    Heyse, Thomas J.
    Solomon, Michael
    Parker, David A.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (11) : 1819 - 1824
  • [40] A computed-tomography-scan-based template to place the femoral component in accurate rotation with respect to the surgical epicondylar axis in total knee arthroplasty
    Oshima, Yasushi
    Lizawa, Norishige
    Kataoka, Tatsunori
    Majima, Tokifumi
    Takai, Shinro
    KNEE, 2018, 25 (01): : 195 - 202