Evaluation of four equivalent formulations for prefabricated diameter vertical drains using flow rates

被引:16
|
作者
Welker, AL [1 ]
Herdin, KM
机构
[1] Villanova Univ, Civil & Environm Engn Dept, Villanova, PA 19085 USA
[2] Langan Engn & Environm Serv Inc, Elmwood Pk, NJ 07407 USA
关键词
geosynthetics; equivalent diameter; prefabricated vertical drains; vertical drains; Wick drains;
D O I
10.1680/gein.10.3.103.37076
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The rectangular cross-section of a prefabricated vertical drain (PVD) is typically converted to a circular cross-section to aid in design. This conversion is performed regardless of whether the PVD will be used for soil improvement or for remediation. An experimental programme to evaluate four of the most commonly used equivalent diameter formulations based on flow rates is described, and the results from those experiments are presented. The results indicate that the formulation recommended by Hansbo in 1979 adequately simulates a PVD under both injection and extraction conditions. Furthermore, there was no dramatic difference observed for the flow rates from, or into, a PVD with and without smear. It should be noted, however, that the tested material was a silty sand, and hence the effect of smear should not be significant.
引用
收藏
页码:103 / 109
页数:7
相关论文
共 50 条
  • [41] Comparison of In Vitro Release Rates of Acyclovir from Cream Formulations Using Vertical Diffusion Cells
    Nallagundla, Sumalatha
    Patnala, Srinivas
    Kanfer, Isadore
    AAPS PHARMSCITECH, 2014, 15 (04): : 994 - 999
  • [42] Evaluation of Smear Zone Extent Surrounding Mandrel Driven Vertical Drains Using the Cavity Expansion Theory
    Sathananthan, Iyathurai
    Indraratna, Buddhima
    Rujikiatkamjorn, Cholachat
    INTERNATIONAL JOURNAL OF GEOMECHANICS, 2008, 8 (06) : 355 - 365
  • [43] Numerical analysis on the effect of flow rates and jet diameter in rewetting vertical nuclear fuel bundle with jet impingements
    Debbarma, Ajoy
    Pandey, Krishna Murari
    ANNALS OF NUCLEAR ENERGY, 2016, 94 : 518 - 529
  • [44] Measurement of flow rates of water in large diameter pipelines using radiotracer dilution method
    Biswal, Jayashree
    Pant, H. J.
    Goswami, Sunil
    Samantray, J. S.
    Sharma, V. K.
    Sarma, K. S. S.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2018, 59 : 194 - 200
  • [45] Evaluation of ambient dose equivalent rates influenced by vertical and horizontal distribution of radioactive cesium in soil in Fukushima Prefecture
    Malins, Alex
    Kurikami, Hiroshi
    Nakama, Shigeo
    Saito, Tatsuo
    Okumura, Masahiko
    Machida, Masahiko
    Kitamura, Akihiro
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2016, 151 : 38 - 49
  • [46] Evaluation of friction factor correlations and equivalent diameter definitions for pipe and annular flow of non-Newtonian fluids
    Dosunmu, Idowu T.
    Shah, Subhash N.
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2013, 109 : 80 - 86
  • [47] Class A and C predictions for Ballina trial embankment with vertical drains using standard test data from industry and large diameter test specimens
    Indraratna, Buddhima
    Baral, Pankaj
    Rujikiatkamjorn, Cholachat
    Perera, Darshana
    COMPUTERS AND GEOTECHNICS, 2018, 93 : 232 - 246
  • [48] A new analytical model for short-time response of vertical ground heat exchangers using equivalent diameter method
    Wei, Jianping
    Wang, Lei
    Jia, Lei
    Zhu, Ke
    Diao, Nairen
    ENERGY AND BUILDINGS, 2016, 119 : 13 - 19
  • [49] Evaluation of interfacial area transport equation in vertical bubbly two-phase flow in large diameter pipes
    Tian, Daogui
    Yan, Changqi
    Sun, Licheng
    ANNALS OF NUCLEAR ENERGY, 2015, 75 : 199 - 209
  • [50] Evaluation of four-terminal-pair capacitance standards using electrical equivalent circuit model
    Satish
    Babita
    Khurana, Bharat
    Kumar, Sachin
    Saxena, A. K.
    MEASUREMENT, 2015, 73 : 121 - 126