Comparative study on the real-time monitoring of a fluid bed drying process of extruded granules using near-infrared spectroscopy and audible acoustic emission

被引:5
|
作者
Aoki, Hisayoshi [1 ]
Hattori, Yusuke [1 ]
Sasaki, Tetsuo [2 ,3 ]
Otsuka, Makoto [1 ,2 ]
机构
[1] Musashino Univ, Fac Pharm, 1-1-20 Shinmachi, Nishi Tokyo 2028585, Japan
[2] Shizuoka Univ, Res Inst Elect, Naka Ku, 3-5-1 Johoku, Hamamatsu, Shizuoka 4328011, Japan
[3] Shizuoka Univ, Grad Sch Med Photon, Naka Ku, 3-5-1 Johoku, Hamamatsu, Shizuoka 4328011, Japan
关键词
Process analytical technology; Calibration model robustness; Fluid-bed drying; Near-infrared spectroscopy; Audible acoustic emission; Partial least squares regression; Granule drying; DIFFUSE-REFLECTANCE SPECTROSCOPY; PROCESS ANALYTICAL TECHNOLOGY; PARTICLE-SIZE DISTRIBUTION; END-POINT DETERMINATION; PHARMACEUTICAL QUALITY; DISCRIMINANT-ANALYSIS; DRUG DISSOLUTION; TABLET HARDNESS; INTACT TABLETS; PREDICTION;
D O I
10.1016/j.ijpharm.2022.121689
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The process of fluidized bed drying of granules was comparatively evaluated by on-line real-time measurements of granule moisture content (MC) using near-infrared spectroscopy (NIR) and audible acoustic emission (AAE). The extruded granules were prepared by kneading a powder blend containing lactose, starch, crystalline cellulose, and riboflavin, with water. The MC of the granules (while they were dried at 35 C in a fluidized bed dryer) was monitored simultaneously with NIR and AAE. The prediction accuracy of the NIR and AAE using partial least squares (PLS) was verified by measuring MC of the granules. The best calibration models following NIR and AAE evaluations consisted of five latent variables with correlation coefficients of 1.000 and 0.998 and root mean square error of 0.259 and 0.615, respectively. As a result of external verification, the accuracy of MC analysis by AAE was slightly lower than that of NIR; however, it was still applicable in practice. Furthermore, the end point of fluidized bed drying process was automatically determined using the PLS discriminant analysis. From the above results, it can be concluded that the AAE-mediated granule drying process can be monitored with sufficient accuracy (compared with NIR).
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Review of near-infrared spectroscopy as a process analytical technology for real-time product monitoring in dairy processing
    Pu, Yuan-Yuan
    O'Donnell, Colm
    Tobin, John T.
    O'Shea, Norah
    INTERNATIONAL DAIRY JOURNAL, 2020, 103
  • [22] Real-time monitoring of meat drying process using microwave spectroscopy
    Muradov, Magomed
    Cullen, Jeff D.
    Abdullah, Badr
    Ateeq, Muhammad
    Mason, Alex
    Shaw, Andy
    Al-Shamma'a, Ahmed, I
    INTERNATIONAL JOURNAL ON SMART SENSING AND INTELLIGENT SYSTEMS, 2014, 7 (05):
  • [23] Real-Time Monitoring of Organic Carrot (var. Romance) During Hot-Air Drying Using Near-Infrared Spectroscopy
    Moscetti, Roberto
    Haff, Ron P.
    Ferri, Serena
    Raponi, Flavio
    Monarca, Danilo
    Liang, Peishih
    Massantini, Riccardo
    FOOD AND BIOPROCESS TECHNOLOGY, 2017, 10 (11) : 2046 - 2059
  • [24] Real-Time Monitoring of Organic Carrot (var. Romance) During Hot-Air Drying Using Near-Infrared Spectroscopy
    Roberto Moscetti
    Ron P. Haff
    Serena Ferri
    Flavio Raponi
    Danilo Monarca
    Peishih Liang
    Riccardo Massantini
    Food and Bioprocess Technology, 2017, 10 : 2046 - 2059
  • [25] Real-time monitoring of organic apple (var. Gala) during hot-air drying using near-infrared spectroscopy
    Moscetti, Roberto
    Raponi, Flavio
    Ferri, Serena
    Colantoni, Andrea
    Monarca, Danilo
    Massantini, Riccardo
    JOURNAL OF FOOD ENGINEERING, 2018, 222 : 139 - 150
  • [26] 110th Anniversary: Real-Time End Point Detection of Fluidized Bed Drying Process Based on a Switching Model of Near-Infrared Spectroscopy
    Mu, Guoqing
    Liu, Tao
    Chen, Junghui
    Xia, Liangzhi
    Yu, Caiyuan
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2019, 58 (36) : 16777 - 16786
  • [27] Real-Time Monitoring of Fecal Nitrogen Excretion to the Environment Using Near-Infrared Reflectance Spectroscopy: A Preliminary Study in Rabbits
    Fortatos, Efstathios
    Hadjigeorgiou, Ioannis
    Mountzouris, Konstantinos C.
    Papadomichelakis, George
    ENVIRONMENTS, 2023, 10 (12)
  • [28] Real-time monitoring for blending uniformity of trimebutine CR tablets using near-infrared and Raman spectroscopy
    Woo, Young-Ah
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2011, 24 (06): : 519 - 526
  • [29] Evaluation of Three Approaches for Real-Time Monitoring of Roller Compaction with Near-Infrared Spectroscopy
    David Acevedo
    Ariel Muliadi
    Arun Giridhar
    James D. Litster
    Rodolfo J. Romañach
    AAPS PharmSciTech, 2012, 13 : 1005 - 1012
  • [30] Evaluation of Three Approaches for Real-Time Monitoring of Roller Compaction with Near-Infrared Spectroscopy
    Acevedo, David
    Muliadi, Ariel
    Giridhar, Arun
    Litster, James D.
    Romanach, Rodolfo J.
    AAPS PHARMSCITECH, 2012, 13 (03): : 1005 - 1012