Freehand C1 lateral mass screw fixation technique: our experience

被引:28
|
作者
Simsek, Serkan [1 ]
Yigitkanli, Kazim [1 ]
Seckin, Hakan [1 ]
Akyol, Cetin [1 ]
Belen, Deniz [1 ]
Bavbek, Murad [1 ]
机构
[1] Diskapi Educ & Res Hosp, Minist Hlth, Dept Neurosurg, TR-06110 Ankara, Turkey
来源
SURGICAL NEUROLOGY | 2009年 / 72卷 / 06期
关键词
C1 lateral mass; C1 pedicle screw; Atlas; Freehand fixation; Lateral mass screw; Occipitocervical fixation; INTERNAL CAROTID-ARTERY; MORPHOMETRIC EVALUATION; QUANTITATIVE ANATOMY; POLYAXIAL SCREW; PLACEMENT; ATLAS; VERTEBRA; PLATE;
D O I
10.1016/j.surneu.2009.06.015
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Although C1 lateral mass fixation technique is frequently performed in upper cervical instabilities, it requires the guidance of fluoroscopic imaging. The fluoroscopy guidance is time-consuming and has the risks of accumulative radiation. Biplane fluoroscopy is also difficult in upper cervical pathologic conditions because of the use of cranial fixations. This study aimed to demonstrate that unicortical C1 lateral mass screws could be placed safely and rapidly without fluoroscopy guidance. Methods: Between 2002 and 2008, 32 C1 lateral mass screws were inserted in 17 consecutive patients with various pathologic conditions involving either atlantoaxial or occipitocervical instability. Results: C1 screw lengths ranged from 18 to 32 mm. The atlantoaxial fixation was performed in 13 patients, and C1 lateral mass screws were added to the occipitocervical construct in 3 patients, to the posterior cervical construct in 2 patients, and to the cervicothoracic construct in 1 patient. In 2 patients, because C1 lateral mass screws could not be inserted unilaterally, C1 pedicle screw analogs were inserted. There were no screw malpositions or neurovascular complications related to screw insertion. Operation time and intraoperative bleeding of the isolated atlantoaxial fixations were retrospectively evaluated. The mean follow-up was w32.3 months (range, 7-59 months). No screw loosening or construct failure was observed within this period. Postoperatively, 4 patients complained of hypoesthesia, whereas one patient had superficial wound infection. Conclusion: C1 lateral mass screws may be used safely and rapidly in upper cervical instabilities without intraoperative fluoroscopy guidance and the use of the spinal navigation systems. Preoperative planning and determining the ideal screw insertion point, the ideal trajections, and the lengths of the screws are the most important points. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:676 / 681
页数:6
相关论文
共 50 条
  • [21] Temporary Internal Fixation Using C1 Lateral Mass Screw and C2 Pedicle Screw (Goel-Harms Technique) without Bone Grafting for Chronic Atlantoaxial Rotatory Fixation
    Matsumoto, Yoshihisa
    Mizutani, Jun
    Suzuki, Nobuyuki
    Otsuka, Seiji
    Hayakawa, Kazuo
    Fukuoka, Muneyoshi
    Wada, Ikuo
    WORLD NEUROSURGERY, 2017, 102 : 696.e1
  • [22] Routine insertion of the lateral mass screw via the posterior arch for C1 fixation: feasibility and related complications
    Yeom, Jin S.
    Kafle, Dinesh
    Ngoc Quyen Nguyen
    Noh, Won
    Park, Kun-Woo
    Chang, Bong-Soon
    Lee, Choon-Ki
    Riew, K. Daniel
    SPINE JOURNAL, 2012, 12 (06): : 476 - 483
  • [23] C1 anatomy and dimensions relative to lateral mass screw placement
    Christensen, David M.
    Eastlack, Robert K.
    Lynch, James J.
    Yaszemski, Michael J.
    Currier, Bradford L.
    SPINE, 2007, 32 (08) : 844 - 848
  • [24] The Intersection Between Lateral Mass and Inferomedial Edge of the C1 Posterior Arch: A Reference Point for C1 Lateral Mass Screw Insertion
    Bunmaprasert, Torphong
    Puangkaew, Watcharapong
    Sugandhavesa, Nantawit
    Liawrungrueang, Wongthawat
    Riew, K. Daniel
    NEUROSPINE, 2021, 18 (02) : 328 - 335
  • [25] C1 lateral mass screw placement via the posterior arch: a technique comparison and anatomic analysis
    Lin, James M.
    Hipp, John A.
    Reitman, Charles A.
    SPINE JOURNAL, 2013, 13 (11): : 1549 - 1555
  • [26] Clinical and radiological Comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation
    Lee, Sun-Ho
    Kim, Eun Sang
    Sung, Joo-Kyung
    Park, Yeun-Mook
    Eoh, Whan
    JOURNAL OF CLINICAL NEUROSCIENCE, 2010, 17 (07) : 886 - 892
  • [27] La maladie de Grisel treated by combined C1-2 transarticular and C1 lateral mass screw fixation
    Pereira, E. A. C.
    Hempenstall, J.
    Pretorius, P. M.
    Kamat, A. A.
    Cadoux-Hudson, T. A. D.
    BRITISH JOURNAL OF NEUROSURGERY, 2010, 24 (04) : 499 - 501
  • [28] Relationship Between Screw Trajectory of C1 Lateral Mass Screw and Internal Carotid Artery
    Murakami, Satona
    Mizutani, Jun
    Fukuoka, Muneyoshi
    Kato, Kenji
    Sekiya, Isato
    Okamoto, Hideki
    Abumi, Kuniyoshi
    Otsuka, Takanobu
    SPINE, 2008, 33 (24) : 2581 - 2585
  • [29] C1 lateral mass screw insertion using cannulated, navigated screws: preliminary results of a novel technique
    Harel, Ran
    Kimchi, Gil
    Perry, Avital
    Knoller, Nachshon
    BRITISH JOURNAL OF NEUROSURGERY, 2023, 37 (06) : 1624 - 1627
  • [30] Clinical Application of a Revised Screw Technique via the C1 Posterior Arch and Lateral Mass in the Pediatric Population
    Yi, Ping
    Dong, Liang
    Tan, Mingsheng
    Wang, Wenjun
    Tang, Xiangsheng
    Yang, Feng
    Zhang, Guangbo
    PEDIATRIC NEUROSURGERY, 2013, 49 (03) : 159 - 165