Mining and Utilization of Reactive Power Capability of Doubly fed Induction Generator Systems for Wind Turbines

被引:0
|
作者
Huang Ya-feng [1 ]
Yan Gan-gui [2 ]
Chao Chu-yan [2 ]
Mu Gang [2 ]
Zhang Zhen-qing [2 ]
Xu Fei [3 ]
Zhang Cheng-xin [4 ]
机构
[1] North China Elect Power Univ, Beijing 102206, Peoples R China
[2] Northeast Dianli Univ, Jilin 132012, Peoples R China
[3] Tsinghua Univ, Beijing 100084, Peoples R China
[4] Innner Mongolia Xuejiawan Elect Power Corp, Xuejiawan 010300, Peoples R China
基金
中国国家自然科学基金;
关键词
Doubly fed induction generator (DFIG); wind power generation; reactive power;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In practical operation, the DFIG systems have large free margin of power capacity which can be used for reactive power adjustment, which is often neglected. Mining and utilization of the reactive power capability of doubly fed Induction generator systems for wind turbines are investigated in this paper. A mathematical model for steady state performance of DFIG WT is presented to analysis of the power characteristic and its control in DFIG systems. The limiting range of reactive power capacity of DFIG and physical limitations in reactive power production are derived in details. A simulation example that dispersing the DFIG WT at the end of an distribution network is given, of which reactive power control strategy, load variation and the change of wind speed are also taken into account. In this case, the voltage level of access point is improved, which demonstrates the validity of utilization of reactive power capability of DFIG WT as an additional continuous reactive power source for utilities.
引用
收藏
页码:1579 / +
页数:2
相关论文
共 50 条
  • [31] Nonlinear control of the doubly-fed induction generator in wind power systems
    Soares, Orlando
    Goncalves, Henrique
    Martins, Antonio
    Carvalho, Adriano
    RENEWABLE ENERGY, 2010, 35 (08) : 1662 - 1670
  • [32] Comparative study on the performance of control systems for doubly fed induction generator (DFIG) wind turbines operating with power regulation
    Fernandez, L. M.
    Garcia, C. A.
    Jurado, F.
    ENERGY, 2008, 33 (09) : 1438 - 1452
  • [33] Improvement of the Low-voltage Ride-through Capability of Doubly Fed Induction Generator Wind Turbines
    Ling, Yu
    Dou, Zhenlan
    Gao, Qiang
    Cai, Xu
    WIND ENGINEERING, 2012, 36 (05) : 535 - 551
  • [34] Improvement of Fault Ride Through Capability of Doubly-Fed Induction Generator Wind Turbines with Hysteresis Controller
    Ling, Yu
    WIND ENGINEERING, 2014, 38 (06) : 659 - 672
  • [35] Aggregated dynamic model for wind farms with doubly fed induction generator wind turbines
    Fernandez, Luis M.
    Jurado, Francisco
    Saenz, Jose Ramon
    RENEWABLE ENERGY, 2008, 33 (01) : 129 - 140
  • [36] Grid disturbance response of wind turbines equipped with induction generator and doubly-fed induction generator
    Thiringer, T
    Petersson, A
    Petru, T
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1542 - 1547
  • [37] Single Grid Connection of Doubly-Fed Induction Generator for Wind Turbines
    Han, Yongsu
    Lee, Wook-Jin
    Ha, Jung-Ik
    2012 IEEE POWER ELECTRONICS AND MACHINES IN WIND APPLICATIONS (PEMWA), 2012,
  • [38] Short-circuit current of wind turbines with doubly fed induction generator
    Morren, Johan
    de Haan, Sjoerd W. H.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) : 174 - 180
  • [39] A variable droop control strategy for doubly fed induction generator wind turbines
    Pan, Wenxia
    Quan, Rui
    Wang, Fei
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2015, 39 (11): : 126 - 131
  • [40] Study of Doubly Fed Induction Generator for Wind Power Application
    Stumpf, P.
    Nagy, I.
    2013 4TH INTERNATIONAL CONFERENCE ON CLEAN ELECTRICAL POWER (ICCEP): RENEWABLE ENERGY RESOURCES IMPACT, 2013, : 368 - 375