Computer-Aided Designed/Computer-Assisted Manufactured Composite Resin Versus Ceramic Single-Tooth Restorations: A 3-Year Clinical Study

被引:0
|
作者
Vanoorbeek, Sara
Vandamme, Katleen [1 ,2 ]
Lijnen, Inge
Naert, Ignace [1 ]
机构
[1] Katholieke Univ Leuven, Dept Prosthet Dent, BIOMAT Res Grp, Sch Dent Oral Pathol & Maxillofacial Surg,Fac Med, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Res Fund, B-3000 Louvain, Belgium
关键词
PROCERA ALLCERAM CROWNS; FREE POLYMER CROWNS; 5-YEAR FOLLOW-UP; LUTING CEMENTS; IN-SERVICE; WEAR; FIT; EXPERIENCE; ANTERIOR; COPINGS;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: No clinical evidence has been provided to suggest that metal-free all-composite resin indirect restorations are a functional and esthetic alternative to all-ceramic restorations. The aim of this study was to evaluate the clinical performance of single-tooth computer-aided design/computer-assisted manufacturing (CAD/CAM)-generated all-composite resin and all-ceramic crowns after 3 years of function. Materials and Methods: In a prospective trial, 200 all-composite resin and all-ceramic crowns were rated over a 3-year period. Restorations were evaluated at 3 weeks and 1 and 3 years after insertion by the California Dental Association quality evaluation index, the patient's self-assessment, marginal fit, periodontal parameters, volume loss, and wear patterns of the veneering material. Statistical analysis was performed using t tests (alpha = .05). Results: Cumulative survival and success rates after 3 years were 87.9% and 55.6% for all-composite resin and 97.2% and 81.2% for all-ceramic crowns, respectively (P < .05 for success rates). Restoration loosening occurred exclusively for all-composite resin crowns cemented on a cast post. All-ceramic restorations demonstrated satisfactory esthetic results. All-composite resin crowns resulted in significantly more mean total volume loss and mean vertical wear at occlusal contact areas after 6 months and 3 years of function. The clinical performance of the CAD/CAM-generated all-ceramic crowns used in this study was similar to that of other all-ceramic CAD/CAM systems. Conclusion: For up to 3 years of function, all-composite resin single-tooth restorations have inferior success rates compared to all-ceramic restorations. Due to the inferior esthetics and wear resistance of all-composite resin crowns, all-ceramic crowns remain the preferred treatment for CAD/CAM-generated metal-free single-tooth restorations. Int J Prosthodont 2010;23:223-230.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 24 条
  • [21] A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single-tooth edentulous area: 3-year follow-up
    Bormann, Kai-Hendrik
    Gellrich, Nils-Claudius
    Kniha, Heinz
    Schild, Sabine
    Weingart, Dieter
    Gahlert, Michael
    BMC ORAL HEALTH, 2018, 18
  • [22] A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single-tooth edentulous area: 3-year follow-up
    Kai-Hendrik Bormann
    Nils-Claudius Gellrich
    Heinz Kniha
    Sabine Schild
    Dieter Weingart
    Michael Gahlert
    BMC Oral Health, 18
  • [24] A 3-year longitudinal prospective study assessing microbial profile and clinical outcomes of single-unit cement-retained implant restorations: Zirconia versus titanium abutments
    de Oliveira Silva, Thalisson S.
    de Freitas, Alice R.
    de Albuquerque Junior, Rubens F.
    Pedrazzi, Vinicius
    Ribeiro, Ricardo F.
    do Nascimento, Cassio
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (03) : 301 - 310