A Combinatorial Electrochemical Biosensor for Sweat Biomarker Benchmarking

被引:19
|
作者
Ganguly, Antra [1 ]
Rice, Paul [1 ]
Lin, Kai-Chun [1 ]
Muthukumar, Sriram [2 ]
Prasad, Shalini [1 ]
机构
[1] Univ Texas Dallas, Dept Bioengn, Biomed Microdevices & Nanotechnol Lab, Richardson, TX 75080 USA
[2] EnLiSense LLC, Allen, TX USA
来源
SLAS TECHNOLOGY | 2020年 / 25卷 / 01期
关键词
sweat biomarker; biomarker normalization; electrochemical sweat sensing; combinatorial sweat sensor; PROLONGED EXERCISE; CORTISOL; DEHYDRATION; CHLORIDE; SENSORS; ARRAYS;
D O I
10.1177/2472630319882003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Misclassification of an acute disease condition as chronic and vice versa by electrochemical sweat biomarker sensors can cause significant psychological, emotional, and financial stress among patients. To achieve higher accuracy in distinguishing between a chronic condition and an acute condition, there is a need to establish a reference biomarker to index the actual chronic disease biomarker of interest by combinatorial sensing. This work provides the first technological proof of leveraging the chloride ion content in sweat for a combinatorial sweat biomarker benchmarking scheme. In this scheme, the sweat chloride ion has been demonstrated as the reference/indexing biomarker, while sweat cortisol has been studied as the disease biomarker of interest. Label-free affinity biosensing is achieved by using a two-electrode electrochemical system on a flexible substrate suitable for wearable applications. The electrochemical stability of the fabricated electrodes for biosensing applications was studied by open-circuit potential measurements. Attenuated total reflectance-Fourier transform infrared spectroscopy spectra validate the crosslinker-antibody binding chemistry. Concentration-dependent analyte-capture probe binding induces a modulation in the electrical properties (charge transfer resistance and double-layer capacitance) at the electrode-sweat buffer interface, which are transduced by nonfaradaic electrochemical impedance spectroscopy (EIS). Calibration dose responses for the sensor for cortisol (5-200 ng/mL) and chloride (10-100 mM) detection were evaluated in synthetic (pH 6) and pooled human sweat (R-2 > 0.95). The variation in the cortisol sensor response due to fluctuations in sweat chloride levels and the significance of reporting normalized biomarker levels were demonstrated to further emphasize the need for biomarker benchmarking in electrochemical sensors.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 50 条
  • [41] A novel immunochromatographic electrochemical biosensor for highly sensitive and selective detection of trichloropyridinol, a biomarker of exposure to chlorpyrifos
    Wang, Limin
    Lu, Donglai
    Wang, Jun
    Du, Dan
    Zou, Zhexiang
    Wang, Hua
    Smith, Jordan N.
    Timchalk, Charles
    Liu, Fengquan
    Lin, Yuehe
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (06): : 2835 - 2840
  • [42] Biomarker benchmarking across ancestral populations
    Nassar, Amin
    Adib, Elio
    Abou Alaiwi, Sarah
    El Zarif, Talal
    Groha, Stefan
    Akl, Elie W.
    Nuzzo, Pier Vitale
    Mouhieddine, Tarek H.
    Perea-Chamblee, Tomin
    Taraszka, Kodi
    EI-Khoury, Habib
    Labban, Muhieddine
    Fong, Christopher
    Arora, Kanika S.
    Labaki, Chris
    Xu, Wenxin
    Sonpavde, Guru P.
    Haddad, Robert I.
    Mouw, Kent W.
    Giannakis, Marios
    Hodi, Stephen
    Zaitlen, Noah
    Schoenfeld, Adam
    Schultz, Nikolaus
    Berger, Michael F.
    MacConaill, Laura E.
    Ananda, Guruprasad
    Kwiatkowski, David J.
    Choueiri, Toni K.
    Schrag, Deborah
    Zhang, Jian-Carrot
    Gusev, Alexander
    [J]. CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2023, 32 (12)
  • [43] Simultaneous detection of tyrosine and uric acid in sweat using CoWO4@CNT with a hydrogel modified electrochemical biosensor
    Zeng, Xin
    Li, Xuheng
    Zhang, Yong
    Wang, Cuncun
    Liu, Yiyi
    Hou, Changjun
    Huo, Danqun
    [J]. ANALYTICAL METHODS, 2024, 16 (34) : 5902 - 5908
  • [44] A chemically modified laser-induced porous graphene based flexible and ultrasensitive electrochemical biosensor for sweat glucose detection
    Yoon, Hyosang
    Nah, Joongsan
    Kim, Hyunsik
    Ko, Seokgyu
    Sharifuzzaman, Md
    Barman, Sharat Chandra
    Xuan, Xing
    Kim, Jiyoung
    Park, Jae Yeong
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2020, 311
  • [45] A wearable flexible electrochemical biosensor with CuNi-MOF@rGO modification for simultaneous detection of uric acid and dopamine in sweat
    Wang, Cuncun
    Zhang, Yong
    Liu, Yiyi
    Zeng, Xin
    Jin, Changpeng
    Huo, Danqun
    Hou, Jingzhou
    Hou, Changjun
    [J]. ANALYTICA CHIMICA ACTA, 2024, 1299
  • [46] Catalytic MXCeO2 for enzyme based electrochemical biosensors: Fabrication, characterization and application towards a wearable sweat biosensor
    Khan, Reem
    Andreescu, Silvana
    [J]. BIOSENSORS & BIOELECTRONICS, 2024, 248
  • [47] Wearable Plasmonic Sweat Biosensor for Acetaminophen Drug Monitoring
    Xiao, Jingyu
    Wang, Jing
    Luo, Yong
    Xu, Tailin
    Zhang, Xueji
    [J]. ACS SENSORS, 2023, 8 (04) : 1766 - 1773
  • [48] Resettable sweat-powered wearable electrochromic biosensor
    Hartel, Martin C.
    Lee, Dongwook
    Weiss, Paul S.
    Wang, Joseph
    Kim, Jayoung
    [J]. BIOSENSORS & BIOELECTRONICS, 2022, 215
  • [49] Resettable sweat-powered wearable electrochromic biosensor
    Hartel, Martin C.
    Lee, Dongwook
    Weiss, Paul S.
    Wang, Joseph
    Kim, Jayoung
    [J]. BIOSENSORS & BIOELECTRONICS, 2022, 215
  • [50] Cisplatin electrochemical biosensor
    Petrlova, Jitka
    Potesil, David
    Zehnalek, Josef
    Sures, Bemd
    Adam, Voitech
    Trnkova, Libuse
    Kizek, Rene
    [J]. ELECTROCHIMICA ACTA, 2006, 51 (24) : 5169 - 5173