Prediction of defibrillation outcome by epicardial activation patterns following shocks near the defibrillation threshold

被引:33
|
作者
Chattipakorn, N [1 ]
Fotuhi, PC [1 ]
Ideker, RE [1 ]
机构
[1] Univ Alabama, Dept Med, Birmingham, AL 35294 USA
关键词
defibrillation; cardiac mapping; fibrillation;
D O I
10.1111/j.1540-8167.2000.tb00174.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Activation Patterns and Defibrillation Outcome. Introduction: Ventricular defibrillation is probabilistic and shock strength dependent. We investigated the relationship between defibrillation outcome and postshock activation patterns for shocks of the same strength (similar to 50% probability of success for defibrillation [ED50] to yield an equal number of successful and failed shocks). Methods and Results: In five pigs, 10 shocks of similar to ED50 strength (right ventricle-superior vena cava, biphasic, 6/4 msec) were delivered after 10 seconds of ventricular fibrillation (VF). Epicardial activation sequences following shocks were mapped with a 504-electrode sock and analyzed by animating dV/dt of the electrograms. Intercycle interval (ICI, time between the onset of successive postshock cycles), wavefront conduction time (WCT, time between the earliest and latest activation of a cycle), and overlapping index (WCT of cycle[n]/ICI of cycle[n+1]) were determined for the first five postshock cycles, An overlapping index >1 indicates overlap between successive cycles. Of 50 defibrillation attempts, 25 were successes. There was no difference between successful and failed episodes for both ICI (68 +/- 9 msec vs 62 +/- 10 msec) and WCT (97 +/- 24 msec vs 100 +/- 14 msec) of cycle 1, However, starting at cycle 2, the ICI was longer, and the WCT was shorter for successful than failed episodes (P < 0.01). Overlapping cycles tinder >1) were found during the transition from cycles 2 through 5 in all failed (index >1) and in no successful episodes. Conclusions: (1) Defibrillation outcome cannot be determined during the first postshock cycle. (2) At least three rapid successive cycles with overlap of cycles 2 and 3 are present in all failed and in no successful episodes. (3) The overlapping index is a marker to predict defibrillation outcome.
引用
收藏
页码:1014 / 1021
页数:8
相关论文
共 50 条
  • [41] Reversing the initial phase polarity of biphasic shocks: Is the effect on the defibrillation threshold reproducible?
    Narasimhan, C
    Sra, J
    Deshpande, S
    Keelan, ET
    Dhala, A
    Panotopoulos, PT
    CIRCULATION, 1996, 94 (08) : 2561 - 2561
  • [42] Nonlinear energy operators for defibrillation Shock Outcome Prediction
    Chicote, Beatriz
    Irusta, Unai
    Aramendi, Elisabete
    Isasi, Iraia
    Alonso, Daniel
    Vicente, Fernando
    Sanchez, Maria
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 61 - 64
  • [43] The effects of acute and chronic amiodarone on activation patterns and defibrillation threshold during ventricular fibrillation in dogs
    Huang, J
    Skinner, JL
    Rogers, JM
    Smith, WM
    Holman, WL
    Ideker, RE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (02) : 375 - 383
  • [44] PREDICTION OF DEFIBRILLATION SUCCESS FROM A SINGLE DEFIBRILLATION THRESHOLD MEASUREMENT WITH SEQUENTIAL PULSES AND 2 CURRENT PATHWAYS IN HUMANS
    JONES, DL
    KLEIN, GJ
    GUIRAUDON, GM
    SHARMA, AD
    YEE, R
    KALLOK, MJ
    CIRCULATION, 1988, 78 (05) : 1144 - 1149
  • [45] Hemodynamic effects and clinical determinants of defibrillation threshold for transvenous atrial defibrillation using biatrial biphasic shocks in patients with chronic atrial fibrillation
    Lok, NS
    Lau, CP
    Ho, DSW
    Tang, YM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (04): : 899 - 908
  • [46] Left ventricular geometry immediately following defibrillation-strength shocks
    Ramanathan, V
    Hoffmeister, BK
    de Jongh, AL
    COMPUTERS IN CARDIOLOGY 2001, VOL 28, 2001, 28 : 241 - 242
  • [47] DEFIBRILLATION IN THE CALF WITH BIDIRECTIONAL TRAPEZOIDAL WAVE SHOCKS APPLIED VIA CHRONICALLY IMPLANTED EPICARDIAL ELECTRODES
    SCHUDER, JC
    GOLD, JH
    STOECKLE, H
    ROBERTS, SA
    MCDANIEL, WC
    MOELLINGER, DW
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1981, 27 : 467 - 470
  • [48] Characteristics of earliest activation following failed atrial defibrillation
    Zheng, XS
    Huang, J
    Ideker, RE
    CIRCULATION, 2002, 106 (19) : 180 - 180
  • [49] COMPARISON OF SEQUENTIAL AND SIMULTANEOUS PULSE DEFIBRILLATION THRESHOLD WITH A NON-EPICARDIAL ELECTRODE SYSTEM
    MEHRA, R
    MARCACCINI, S
    CIRCULATION, 1986, 74 (04) : 184 - 184
  • [50] EPICARDIAL ADMINISTRATION OF IBUTILIDE FROM POLYURETHANE MATRICES - EFFECTS ON DEFIBRILLATION THRESHOLD AND ELECTROPHYSIOLOGIC PARAMETERS
    LABHASETWAR, V
    UNDERWOOD, T
    HEIL, RW
    GALLAGHER, M
    LANGBERG, J
    LEVY, RJ
    JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 1994, 24 (05) : 826 - 840