X-ray tomography using a CMOS area detector

被引:1
|
作者
Brunetti, A.
Cesareo, R.
机构
[1] Univ Sassari, Dept Math & Phys, I-07100 Sassari, Italy
[2] Ist Nazl Fis Nucl, Sez Cagliari, Cagliari, Italy
关键词
flat panel; imaging; tomography;
D O I
10.1016/j.nimb.2007.02.067
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A flat panel based on CMOS technology represents a valid alternative to other kinds of flat panels and to ccd detectors for X-ray imaging. Although the spatial resolution of the ccd sensors is better than that of a CMOS sensor, the last has a larger sensitive-area and it can work at room temperature reaching a dynamic performance comparable to that of a cooled ccd sensor. Other kinds of flat panels, such as TFT screen are much more expensive and they have lower spatial resolution and higher noise than the CMOS detector. In this paper, an application of the CMOS sensor to X-ray tomography is described. Preliminary results are reported and discussed. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:485 / 489
页数:5
相关论文
共 50 条
  • [1] A large area CMOS detector for shutterless collection of x-ray diffraction data
    Thompson, A. C.
    Westbrook, E. M.
    Lavender, W. M.
    Nix, J. C.
    17TH PAN-AMERICAN SYNCHROTRON RADIATION INSTRUMENTATION CONFERENCE SRI2013, 2014, 493
  • [2] X-RAY POLE FIGURE MEASUREMENT USING AN AREA DETECTOR
    KLEIN, H
    PARK, NJ
    NAUERGERHARDT, CU
    ZEITSCHRIFT FUR METALLKUNDE, 1994, 85 (08): : 574 - 580
  • [3] X-ray imaging using CCD based area detector
    Sinha, A
    SOLID STATE PHYSICS, VOL 41, 1998, 1999, : 71 - 74
  • [4] A large-area CMOS imager as an X-ray detector for synchrotron radiation experiments
    Yagi, N
    Yamamoto, M
    Uesugi, K
    Inoue, K
    JOURNAL OF SYNCHROTRON RADIATION, 2004, 11 : 347 - 352
  • [5] Comparison of a Large Area CZT Detector to a Spectroscopic CdTe Detector for X-ray Fluorescence Computed 'Tomography
    Vernekohl, Don
    Streicher, Michael
    Ahmad, Moiz
    Xing, Lei
    He, Zhong
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [6] Characteristic of X-ray Tomography Performance using CdTe Timepix Detector
    Zain, R. M.
    O'Shea, V.
    Maneuski, D.
    ADVANCING NUCLEAR SCIENCE AND ENGINEERING FOR SUSTAINABLE NUCLEAR ENERGY KNOWLEDGE, 2017, 1799
  • [7] Fluorescence X-ray Computed Tomography Using CdTe Detector Array
    Yoon, Changyeon
    Lee, Wonho
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [8] X-ray tomography of microdefects using a detector with nonuniform surface sensitivity
    Likhachev A.V.
    Bulletin of the Russian Academy of Sciences: Physics, 2013, 77 (2) : 95 - 98
  • [9] Indirectly illuminated X-ray area detector for X-ray photon correlation spectroscopy
    Shinohara, Yuya
    Imai, Ryo
    Kishimoto, Hiroyuki
    Yagi, Naoto
    Amemiya, Yoshiyuki
    JOURNAL OF SYNCHROTRON RADIATION, 2010, 17 : 737 - 742
  • [10] Digital X-ray microscopy with a microfocal X-ray generation and an MWPC area detector
    Bateman, J.E.
    Moss, G.R.
    Rockett, P.
    Webb, S.
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 767 - 772