Nanostructured impedimetric lectin-based biosensor for arboviruses detection

被引:42
|
作者
Simao, Estefani P. [1 ]
Silva, Dammyres B. S. [2 ]
Cordeiro, Marli T. [3 ]
Gil, Laura H. V. [3 ]
Andrade, Cesar A. S. [2 ]
Oliveira, Maria D. L. [1 ,2 ]
机构
[1] Univ Fed Pernambuco, Programa Posgrad Ciencias Biol, BR-50670901 Recife, PE, Brazil
[2] Univ Fed Pernambuco, Dept Bioquim, BR-50670901 Recife, PE, Brazil
[3] Inst Aggeu Magalhaes Fiocruz, Dept Virol, BR-50670420 Recife, PE, Brazil
关键词
Concanavalin A; Nanoparticles; Arboviruses; Biosensor; Impedance spectroscopy; ZINC-OXIDE NANOPARTICLES; BORON-NITRIDE NANOSHEETS; GOLD NANOPARTICLES; SENSOR; DENGUE; CHIKUNGUNYA; DIAGNOSIS; SEROTYPE;
D O I
10.1016/j.talanta.2019.120338
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Arboviruses have been emerging as a significant global health problem due to the recurrent epidemics. Arboviruses require the development of new diagnostic devices due to the nonspecific clinical manifestations. Herein, we report a biosensor based on cysteine (Cys), zinc oxide nanoparticles (ZnONp), and Concanavalin A (ConA) lectin to differentiate between arboviruses infections. ConA is capable of interacting with the saccharide components of the viral capsid. In this study, we evaluated the reproducibility, sensitivity, and specificity of the sensor for the virus of Dengue type 2 (DENV2), Zika (ZIKV), Chikungunya (CHIKV), and Yellow fever (YFV). Atomic force microscopy measurements confirmed the electrode surface modification and revealed a heterogeneous topography during the biorecognition process. Cyclic voltammetry (CV) and impedance spectroscopy (EIS) were used to characterize the biosensor. The blockage of the oxidation-reduction process is related to the formation of Cys-ZnONp-ConA system on the electroactive area and its subsequent interaction with viral glycoproteins. The sensor exhibited a linear response to different concentrations of the studied arboviruses. Our study demonstrates that ConA lectin recognizes the structural glycoproteins of the DENV2, ZIKV, CHIKV, and YFV. DENV2 is the most structurally similar to ZIKV. Our results have shown that the impedimetric response correlates with the structural glycoproteins, as follow: DENV2 (18.6 k Omega) > ZIKV (14.6 k Omega) > CHIKV (6.86 k Omega) > YFV (5.98 k Omega). The homologous structural regions contribute to ConA-arboviruses recognition. Our results demonstrate the use of the proposed system for the development of biosensors for arboviruses infections.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Electrochemical lectin-based biosensor array for detection and discrimination of carcinoembryonic antigen using dual amplification of gold nanoparticles and horseradish peroxidase
    Zhao, Lingzhi
    Li, Congcong
    Qi, Honglan
    Gao, Qiang
    Zhang, Chengxiao
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 235 : 575 - 582
  • [22] Lectin-based detection of Escherichia coli and Staphylococcus aureus by flow cytometry
    Hendrickson, Olga D.
    Nikitushkin, Vadim D.
    Zherdev, Anatoly V.
    Dzantiev, Boris B.
    ARCHIVES OF MICROBIOLOGY, 2019, 201 (03) : 313 - 324
  • [23] Detection of phosphoglucomutase-3 deficiency by lectin-based flow cytometry
    Carlson, Ryan J.
    Bond, Michelle R.
    Hutchins, Shermaine
    Brown, Yishai
    Wolfe, Lynne A.
    Lam, Christina
    Nelson, Celeste
    DiMaggio, Thomas
    Jones, Nina
    Rosenzweig, Sergio D.
    Stone, Kelly D.
    Freeman, Alexandra F.
    Holland, Steven M.
    Hanover, John A.
    Milner, Joshua D.
    Lyons, Jonathan J.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2017, 140 (01) : 291 - +
  • [24] Interdigitated impedimetric-based Maackia amurensis lectin biosensor for prostate cancer biomarker
    Siti Fatimah Abd Rahman
    Mohd Khairuddin Md Arshad
    Subash C. B. Gopinath
    Mohamad Faris Mohamad Fathil
    Frédéric Sarry
    Conlathan Ibau
    Omar Elmazria
    Sami Hage-Ali
    Microchimica Acta, 2024, 191
  • [25] Interdigitated impedimetric-based Maackia amurensis lectin biosensor for prostate cancer biomarker
    Rahman, Siti Fatimah Abd
    Arshad, Mohd Khairuddin Md
    Gopinath, Subash C. B.
    Fathil, Mohamad Faris Mohamad
    Sarry, Frederic
    Ibau, Conlathan
    Elmazria, Omar
    Hage-Ali, Sami
    MICROCHIMICA ACTA, 2024, 191 (02)
  • [26] Lectin-based detection of Escherichia coli and Staphylococcus aureus by flow cytometry
    Olga D. Hendrickson
    Vadim D. Nikitushkin
    Anatoly V. Zherdev
    Boris B. Dzantiev
    Archives of Microbiology, 2019, 201 : 313 - 324
  • [27] Sensitive impedimetric biosensor for direct detection of diazinon based on lipases
    Zehani, Nedjla
    Dzyadevych, Sergei V.
    Kherrat, Rochdi
    Jaffrezic-Renault, Nicole J.
    FRONTIERS IN CHEMISTRY, 2014, 2
  • [28] Impedimetric biosensor based on magnetic nanoparticles for electrochemical detection of dopamine
    Chandra, Sudeshna
    Arora, Kunal
    Bahadur, D.
    MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2012, 177 (17): : 1531 - 1537
  • [29] Optimization of aptamer-based impedimetric biosensor for detection of sarcosine
    Canbay, Z. Celik
    Ozyurt, C.
    Mengulluoglu, U.
    Dinckaya, E.
    Evran, S.
    FEBS OPEN BIO, 2018, 8 : 491 - 491
  • [30] Impedimetric biosensor for cancer cell detection
    Seven, Basak
    Bourourou, Mariem
    Elouarzaki, Kamal
    Constant, Jean Francois
    Gondran, Chantal
    Holzinger, Michael
    Cosnier, Serge
    Timur, Suna
    ELECTROCHEMISTRY COMMUNICATIONS, 2013, 37 : 36 - 39