Cut-off value of the ankle-brachial pressure index at which the accuracy of brachial-ankle pulse wave velocity measurement is diminished

被引:83
|
作者
Motobe, K
Tomiyama, H
Koji, Y
Yambe, M
Gulinisa, Z
Arai, T
Ichihashi, H
Nagae, T
Ishimaru, S
Yamashina, A
机构
[1] Tokyo Med Univ, Dept Internal Med 2, Shinjuku Ku, Tokyo 1600023, Japan
[2] Tokyo Med Univ, Dept Surg 2, Tokyo 1600023, Japan
关键词
accuracy; ankle-brachial pressure index; arterial stenosis; pulse wave velocity;
D O I
10.1253/circj.69.55
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The present study was conducted to establish the cutoff value of the ankle-brachial pressure index (ABI) at which the accuracy of brachial-ankle pulse wave velocity (baPWV) measurement is diminished. Methods and Results The baPWV and ABI were measured in 1,361 patients with an atherosclerosis-related disease and 7,889 subjects without any atherosclerotic risk factors, in order to determine the percent difference of the brachial-ankle PWV (%baPWV), the angle of the rise of the anacrotic limb (%angle) and of the amplitude of the entire waveform (%amplitude) in both sides. The %angle and %amplitude were significantly higher in subjects whose %baPWV was greater than or equal to19% than in those subjects whose %baPWV was <19% (19% was the mean value+3SD of 7,889 healthy subjects). The %baPWV greater than or equal to19% was defined as the abnormal discrepancy of baPWV caused by arterial stenosis in both sides. The receiver operator characteristic curve discriminated the abnormal discrepancy of baPWV by ABI because the area under the curve was 0.86. The highest discriminating sensitivity and specificity were 91% and 75% at ABI=0.95. Conclusion An ABI <0.95 seems to be the marker of diminished baPWV accuracy.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 50 条
  • [21] Brachial-Ankle Pulse Wave Velocity and Ankle-Brachial Index in Japanese Migraineurs without Cardiovascular Disease Risk Factors
    Ikeda, K.
    Iwamoto, K.
    Hirayama, T.
    Takazawa, T.
    Kawase, Y.
    Yoshii, Y.
    Kano, O.
    Kawabe, K.
    Iwasaki, Y.
    HEADACHE, 2011, 51 : 17 - 18
  • [22] Comparison of arteriosclerotic indicators in patients with ischemic stroke: ankle-brachial index, brachial-ankle pulse wave velocity and cardio-ankle vascular index
    Saji, Naoki
    Kimura, Kazumi
    Yagita, Yoshiki
    Kawarai, Toshitaka
    Shimizu, Hirotaka
    Kita, Yasushi
    HYPERTENSION RESEARCH, 2015, 38 (05) : 323 - 328
  • [23] Effects of heart rate on brachial-ankle pulse wave velocity and ankle-brachial pressure index in patients without significant organic heart disease
    Su, Ho-Ming
    Lee, Kun-Tai
    Chu, Chih-Sheng
    Lee, Ming-Yi
    Lin, Tsung-Hsien
    Voon, Wen-Chol
    Sheu, Sheng-Hsiung
    Lai, Wen-Ter
    ANGIOLOGY, 2007, 58 (01) : 67 - 74
  • [24] Ankle-brachial index and brachial-ankle pulse wave velocity are risk factors for ischemic stroke in patients with type 2 diabetes
    Ting Li
    Xiu-juan Wu
    Xiao-min Chen
    Si-bo Wang
    Kang-ding Liu
    Ying-qi Xing
    NeuralRegenerationResearch, 2017, 12 (11) : 1853 - 1859
  • [25] Correlation analysis of ankle-brachial index and brachial-ankle pulse wave velocity with cardiac structures and functions in patients with essential hypertension
    Li, Y. -L.
    Song, X.
    Ren, J. -C.
    Li, X. -G.
    Hou, S. -A.
    Miao, C.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2017, 21 (24) : 5798 - 5804
  • [26] Ankle-brachial index and brachial-ankle pulse wave velocity are risk factors for ischemic stroke in patients with Type 2 diabetes
    Li, Ting
    Wu, Xiu-juan
    Chen, Xiao-min
    Wang, Si-bo
    Liu, Kang-ding
    Xing, Ying-qi
    NEURAL REGENERATION RESEARCH, 2017, 12 (11) : 1853 - +
  • [27] Cut-Off Value of Brachial-Ankle Pulse Wave Velocity to Predict Cardiovascular Disease in Hypertensive Patients: A Cohort Study
    Kawai, Tatsuo
    Ohishi, Mitsuru
    Onishi, Miyuki
    Ito, Norihisa
    Takeya, Yasushi
    Maekawa, Yoshihiro
    Rakugi, Hiromi
    JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2013, 20 (04) : 391 - 400
  • [28] Clinical usefulness of ankle brachial index and brachial-ankle pulse wave velocity in patients with ischemic stroke
    Lee, Hyung-Suk
    Lee, Hye Lim
    Han, Ho-seong
    Yeo, Minju
    Kim, Ji Seon
    Lee, Sung-Hyun
    Lee, Sang-Soo
    Shin, Dong-Ick
    JOURNAL OF BIOMEDICAL RESEARCH, 2016, 30 (04): : 285 - 291
  • [29] Clinical usefulness of ankle brachial index and brachial-ankle pulse wave velocity in patients with ischemic stroke
    Hyung-Suk Lee
    Hye Lim Lee
    Ho-seong Han
    Minju Yeo
    Ji Seon Kim
    Sung-Hyun Lee
    Sang-Soo Lee
    Dong-Ick Shin
    The Journal of Biomedical Research, 2016, 30 (04) : 285 - 291
  • [30] Clinical Usefulness of Ankle Brachial Index and Brachial-Ankle Pulse Wave Velocity in Patients with Ischemic Stroke
    Han, H. S.
    Lee, H. S.
    Lee, J. K.
    Lee, Y. S.
    Shin, D., I
    CEREBROVASCULAR DISEASES, 2016, 42 : 76 - 76