共 50 条
Study on diagnostic value of quantitative parameters of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) in prostate cancer
被引:9
|作者:
Yao, Weigen
[1
]
Liu, Jie
[1
]
Zheng, Jiaju
[1
]
Lu, Pengcong
[1
]
Zou, Shufang
[2
]
Xu, Ying
[3
]
机构:
[1] Yuyao Peoples Hosp Zhejiang Prov, Dept Radiol, 800 ChengDong Rd, Yuyao 315400, Zhejiang, Peoples R China
[2] Yuyao Peoples Hosp Zhejiang Prov, Dept Urol Surg, Yuyao, Zhejiang, Peoples R China
[3] Yuyao Peoples Hosp Zhejiang Prov, Dept Pathol, Yuyao, Zhejiang, Peoples R China
来源:
关键词:
Diffusion-weighted MR imaging;
intravoxel incoherent motion;
prostate cancer;
differential diagnosis;
CARCINOMA;
DIFFERENTIATION;
D O I:
暂无
中图分类号:
R73 [肿瘤学];
学科分类号:
100214 ;
摘要:
Objective: To investigate the diagnostic value of quantitative parameters of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) in prostate cancer. Methods: From January 2019 to June 2020, 96 patients with prostatic tumor admitted in the department of urological surgery of our hospital were selected as subjects. Magnetic resonance imaging data of 48 cases of benign prostatic hyperplasia and 48 cases of prostate cancer were retrospectively analyzed. The patients included in this study received conventional MRI and IVIM-DWI examinations. Quantitative parameters of IVIM-DWI including D value, D* value, apparent diffusion coefficient (ADC) value and f value in lesions of prostatic tumor were calculated through the double exponential model fitting algorithm. D value, D* value, ADC value and f value were compared between benign prostatic hyperplasia (BPH) group and prostate cancer group. Quantitative parameters of IVIM-DWI were also compared among patients from different Gleason scores groups. The correlation of quantitative parameters of IVIM-DWI with Gleason scores and PSA concentration was analyzed. Diagnostic efficiency of quantitative parameters of IVIM-DWI for prostate cancer was evaluated by ROC curve. Results: Compared with those in BPH group, D value, ADC value and f value in prostate cancer group were significantly lower, but D* value was obviously higher. With the Gleason score increased, D value, ADC value and f value gradually decreased, while D* value gradually increased. The diagnostic efficiency of parameters ADC and D was higher among other parameters. D value, ADC value and f value of prostate cancer were negatively correlated with Gleason score and PSA concentration, respectively (all P<0.05), while D* value was positively correlated with Gleason score and PSA concentration. Conclusions: Quantitative parameters of IVIM-DWI could be used for the diagnosis and evaluation of prostate cancer, and quantitative parameters of IVIM-DWI were associated with Gleason score and PSA concentration.
引用
收藏
页码:3696 / 3702
页数:7
相关论文