Determinants of coronary blood flow in humans:: quantification by intracoronary Doppler and ultrasound

被引:34
|
作者
Wieneke, H [1 ]
von Birgelen, C [1 ]
Haude, M [1 ]
Eggebrecht, H [1 ]
Möhlenkamp, S [1 ]
Schmermund, A [1 ]
Böse, D [1 ]
Altmann, C [1 ]
Bartel, T [1 ]
Erbel, R [1 ]
机构
[1] Univ Essen Gesamthsch, Dept Cardiol, D-45122 Essen, Germany
关键词
ultrasonics; microcirculation; coronary flow; left ventricular muscle mass;
D O I
10.1152/japplphysiol.00724.2004
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The direct determinants of coronary flow are lumen area and blood flow velocity; however, the precise mechanisms that control these factors are not fully understood. The aim of the present study was to assess by which mechanisms lumen area and coronary flow velocity interact with hemodynamic and morphometric factors, thereby influencing coronary flow. Intracoronary Doppler and ultrasound measurements were performed in 28 patients without coronary lumen irregularities. Flow velocity and lumen cross-sectional area were measured in the proximal segments of all three coronary arteries. Global lumen cross-sectional area and global flow were obtained by adding up the values of all three coronary arteries. Left ventricular mass was assessed by echocardiography. Stress-mass-heart rate and pressure-rate products reflecting myocardial oxygen demand were calculated. Global coronary flow increased during adenosine-induced hyperemia from 197 +/- 72 to 637 +/- 204 ml/min ( P < 0.001). Global coronary flow closely correlated with the stress-mass-heart rate product ( r = 0.62; P < 0.001). Looking at the two constituents of flow separately, global coronary cross-sectional area was closely related to left ventricular muscle mass ( r = 0.61; P < 0.001), whereas mean coronary flow velocity at rest showed a strong linear relation with the pressure-rate product ( r = 0.64; P < 0.001). There was no interaction between cross-sectional area and blood flow velocity in any of the coronary vessels. Coronary lumen size and flow velocity, the two determinants of coronary flow, are principally determined by different physiological factors. Long-term flow adaptation is achieved by an increase in coronary lumen size, whereas short-term myocardial oxygen requirements are met by changes in resting flow velocity.
引用
收藏
页码:1076 / 1082
页数:7
相关论文
共 50 条
  • [1] Coronary blood flow quantification using magnetic resonance phase mapping: Comparison with intracoronary Doppler flow measurement
    Kessler, W
    Stingl, D
    Moshage, W
    Galland, A
    Nitz, W
    Laub, G
    Bachmann, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 23102 - 23102
  • [2] Assessment of coronary blood flow in humans using phase difference MR imaging - Comparison with intracoronary Doppler flow measurement
    Kessler, W
    Moshage, W
    Galland, A
    Zink, D
    Achenbach, S
    Nitz, W
    Laub, G
    Bachmann, K
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1998, 14 (03): : 179 - 186
  • [3] IMPROVEMENT OF CORONARY MORPHOLOGY AND BLOOD-FLOW AFTER STENTING - ASSESSMENT BY INTRAVASCULAR ULTRASOUND AND INTRACORONARY DOPPLER
    GE, JB
    ERBEL, R
    ZAMORANO, J
    HAUDE, M
    KEARNEY, P
    GORGE, G
    MEYER, J
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1995, 11 (02): : 81 - 87
  • [4] Assessment of angiographic coronary slow flow phenomenon with intracoronary ultrasound and doppler flow mapping
    Junbo Ge
    Helge Simon
    Allen Jeremias
    Fengqi Liu
    Günter Grge
    Michael Haude
    Detrich Baumgart and Raimund Erbel
    Chinese Medical Journal, 1997, (12)
  • [5] Assessment of angiographic coronary slow flow phenomenon with intracoronary ultrasound and doppler flow mapping
    Ge, JB
    Simon, H
    Jeremias, A
    Liu, FQ
    Gorge, G
    Haude, M
    Baumgart, D
    Erbel, R
    CHINESE MEDICAL JOURNAL, 1997, 110 (12) : 922 - 922
  • [7] Multiple coronary artery left ventricular fistulae: Haemodynamic quantification by intracoronary Doppler ultrasound
    Meissner, A
    Lins, M
    Herrmann, G
    Simon, R
    HEART, 1997, 78 (01) : 91 - 93
  • [8] Assessing coronary blood flow dynamics with the TIMI frame count method: Comparison with simultaneous intracoronary Doppler and ultrasound
    Tanedo, JS
    Kelly, RF
    Marquez, M
    Burns, DE
    Klein, LW
    Costanzo, MR
    Parrillo, JE
    Hollenberg, SM
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 53 (04) : 459 - 463
  • [9] Normal coronary physiology assessed by intracoronary Doppler ultrasound
    Webb, CM
    Collins, P
    Di Mario, C
    HERZ, 2005, 30 (01) : 8 - 16
  • [10] Effects of the intracoronary infusion of cocaine on coronary arterial dimensions and blood flow in humans
    Daniel, WC
    Lange, RA
    Landau, C
    Willard, JE
    Hillis, LD
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (03): : 288 - 291