IMPROVEMENT OF CORONARY MORPHOLOGY AND BLOOD-FLOW AFTER STENTING - ASSESSMENT BY INTRAVASCULAR ULTRASOUND AND INTRACORONARY DOPPLER

被引:24
|
作者
GE, JB [1 ]
ERBEL, R [1 ]
ZAMORANO, J [1 ]
HAUDE, M [1 ]
KEARNEY, P [1 ]
GORGE, G [1 ]
MEYER, J [1 ]
机构
[1] UNIV MAINZ, MED CLIN 2, MAINZ, GERMANY
来源
关键词
INTRAVASCULAR ULTRASOUND; INTRACORONARY DOPPLER; STENTING; PTCA;
D O I
10.1007/BF01844705
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intravascular ultrasound (IVUS) and intracoronary Doppler (ICD) were performed in eight patients (54.3 +/- 6.5 years, 6 male) immediately after PTCA and after stenting. ICD was also performed before PTCA. After PTCA, IVUS has demonstrated intimal rupture in all patients. After stenting, IVUS revealed wall wrapping of the intimal flap with a free lumen in all patients. The lumen diameter was 2.42 +/- 0.55 mm after PTCA and was 2.74 +/- 0.49 mm after stenting (p < 0.001). The cross-sectional area increased from 4.70 +/- 1.99 mm(2) post-PTCA to 6.40 +/- 2.15 mm(2) post-stent (p < 0.005). Coronary flow velocity reserve, calculated by the ratio of mean flow velocity at rest and after intracoronary papaverine administration, increased from 2.05 +/- 1.01 to 2.99 +/- 1.14 after PTCA (p = 0.015); and increased to 4.51 +/- 1.33 after stenting (p < 0.001). The morphological data derived from IVUS correlated with the functional information obtained with ICD. In addition to its established role in bail out situations, stent implantation may be considered when a suboptimal morphological and functional result has been demonstrated.
引用
收藏
页码:81 / 87
页数:7
相关论文
共 50 条
  • [1] Determinants of coronary blood flow in humans:: quantification by intracoronary Doppler and ultrasound
    Wieneke, H
    von Birgelen, C
    Haude, M
    Eggebrecht, H
    Möhlenkamp, S
    Schmermund, A
    Böse, D
    Altmann, C
    Bartel, T
    Erbel, R
    JOURNAL OF APPLIED PHYSIOLOGY, 2005, 98 (03) : 1076 - 1082
  • [2] Role of coronary artery lumen enlargement in improving coronary blood flow after balloon angioplasty and stenting: A combined intravascular ultrasound Doppler flow and imaging study
    Kern, MJ
    Dupouy, P
    Drury, JH
    Aguirre, FV
    Aptecar, E
    Bach, RG
    Caracciolo, EA
    Donohue, TJ
    Rande, JLD
    Geschwind, HJ
    Mechem, CJ
    Kane, G
    Teiger, E
    Wolford, TL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (07) : 1520 - 1527
  • [3] Intravascular ultrasound predictors of changes in coronary flow reserve after intracoronary stents
    Pinto, I
    Mattos, L
    Tanajura, L
    Centemero, M
    Chaves, A
    Feres, F
    Abizaid, A
    Abizaid, A
    Sousa, A
    Sousa, JE
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 : TC212 - TC212
  • [4] Assessment of angiographic coronary slow flow phenomenon with intracoronary ultrasound and doppler flow mapping
    Junbo Ge
    Helge Simon
    Allen Jeremias
    Fengqi Liu
    Günter Grge
    Michael Haude
    Detrich Baumgart and Raimund Erbel
    Chinese Medical Journal, 1997, (12)
  • [5] Assessment of angiographic coronary slow flow phenomenon with intracoronary ultrasound and doppler flow mapping
    Ge, JB
    Simon, H
    Jeremias, A
    Liu, FQ
    Gorge, G
    Haude, M
    Baumgart, D
    Erbel, R
    CHINESE MEDICAL JOURNAL, 1997, 110 (12) : 922 - 922
  • [7] Assessment of intraindividual variability of coronary flow reserve in angiographically normal coronary arteries in transplant recipients:: A study with intracoronary Doppler and intravascular ultrasound
    Rieber, J
    Klauss, V
    König, A
    Henneke, KH
    Spes, C
    Regar, E
    Werner, F
    Meiser, B
    Reichart, B
    Theisen, K
    Mudra, H
    TRANSPLANTATION PROCEEDINGS, 1998, 30 (05) : 1926 - 1927
  • [8] Restenosis after coronary stenting guided by intracoronary Doppler flow velocity reserve measurements
    Haude, M
    Baumgart, D
    Caspari, G
    Welge, D
    Ge, J
    Liu, F
    Erbel, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 396A - 397A
  • [9] Intravascular ultrasound findings in patients with abnormal coronary flow reserve after stenting
    Muramatsu, T
    Tsukahara, R
    Ho, M
    Ito, Y
    Ishimori, H
    Saiki, N
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 52 (04) : 420 - 424
  • [10] CAN AN INTRACORONARY DOPPLER WIRE ACCURATELY MEASURE CHANGES IN CORONARY BLOOD-FLOW VELOCITY
    VANYI, J
    BOWERS, T
    JARVIS, G
    WHITE, CW
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 29 (03): : 240 - 246