A Wearable Respiration Monitoring System Based on Digital Respiratory Inductive Plethysmography

被引:32
|
作者
Wu, Dan [1 ,2 ]
Wang, Lei [3 ]
Zhang, Yuan-Ting [1 ,2 ]
Huang, Bang-Yu [3 ]
Wang, Bo [3 ]
Lin, Shao-Jie [3 ]
Xu, Xiao-Wen [4 ]
机构
[1] Chinese Univ Hong Kong, Joint Res Ctr Biomed Engn, Hong Kong, Hong Kong, Peoples R China
[2] Chinese Acad Sci, Hlth Engn, Key Lab Biomed Informat, Beijing, 518067, Peoples R China
[3] Chinese Acad Sci, Shenzhen Inst Adv Tehnol, Hlth Engn, Key Lab Biomed Informat, Beijing, 518067, Peoples R China
[4] Cent South Univ Technol, Sch Infophys & Geomat Engn, Changsha 410083, Peoples R China
关键词
D O I
10.1109/IEMBS.2009.5332665
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper we present a wearable device for continuous monitoring of respiration signal and the associated algorithm for signal evaluations. The device took advantages of a proven respiratory inductive plethysmograph (RIP) technology and a wireless body sensor networks (BSN) development platform. The textile RIP sensor was integrated into a suit that could be comfortably worn around thorax or abdomen for monitoring respiration during sleep. A smart signal processing algorithm was implemented for extracting the dynamic respiration rate. The results of in-situ experiments from ten healthy subjects suggested that our system worked as intended. Due to the high reliability and low cost of our system it is believed to meet the future demands on home-based monitoring and diagnosis of sleep disorder-related diseases.
引用
收藏
页码:4844 / +
页数:2
相关论文
共 50 条
  • [21] Evaluation of respiratory inductive plethysmography - Accuracy for analysis of respiratory waveforms
    Carry, PY
    Baconnier, P
    Eberhard, A
    Cotte, P
    Benchetrit, G
    CHEST, 1997, 111 (04) : 910 - 915
  • [22] Respiratory inductive plethysmography to assess respiratory variability and complexity in humans
    Fiamma, Marie-Noelle
    Samara, Ziyad
    Baconnier, Pierre
    Similowski, Thomas
    Straus, Christian
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2007, 156 (02) : 234 - 239
  • [23] A wearable respiratory plethysmography using flexible sensor
    Esfahani, Mohammad Iman Mokhlespour
    Narimani, Roya
    Ramezanzadehkoldeh, Masoud
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2013, 11 (04) : 364 - 380
  • [24] A wearable wireless respiration rate monitoring system based on fiber optic sensors
    Elsarnagawy, Tarek
    Farrag, Manal
    Haueisen, Jens
    Abulaal, Magdy
    Mahmoud, Khalid
    Fouad, H.
    Ansari, S.G.
    Sensor Letters, 2014, 12 (09) : 1331 - 1336
  • [25] VALIDATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY IN CHRONIC AIRWAYS OBSTRUCTION
    TOBIN, MJ
    JENOURI, G
    WATSON, H
    SACKNER, MA
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1982, 125 (04): : 122 - 122
  • [26] Evaluation of Respiratory Inductive Plethysmography in VLBW infants 1709
    Gabriel Musante
    Nelson Claure
    Tilo Gerhardt
    Ruth Everett
    Eduardo Bancalari
    Pediatric Research, 1998, 43 (Suppl 4) : 291 - 291
  • [27] Respiratory function parameters in infants using inductive plethysmography
    Selbie, RD
    Fletcher, M
    Arestis, N
    White, R
    Duncan, A
    Helms, P
    Duffty, P
    MEDICAL ENGINEERING & PHYSICS, 1997, 19 (06) : 501 - 511
  • [28] VALIDATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY WITH CHANGE IN BODY POSTURE
    CHADHA, TS
    SACKNER, MA
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1983, 128 (02): : 331 - 331
  • [29] Respiratory Monitoring by Inductive Plethysmography in Unrestrained Subjects Using Position Sensor-Adjusted Calibration
    Bruellmann, Gregor
    Fritsch, Karsten
    Thurnheer, Robert
    Bloch, Konrad E.
    RESPIRATION, 2010, 79 (02) : 112 - 120
  • [30] COMPARISON OF CALIBRATION METHODS FOR RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY IN INFANTS
    REVOW, MD
    ENGLAND, SJ
    STOGRYN, HAF
    WILKES, DL
    JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (05) : 1853 - 1861