Comparison of traditional methods and mitogen-stimulated direct antiglobulin test for detection of anti-red blood cell autoimmunity

被引:26
|
作者
Barcellini, Wilma [1 ]
Revelli, Nicoletta [2 ]
Imperiali, Francesca Guia [1 ]
Villa, Maria Antonietta [2 ]
Manera, Maria Cristina [2 ]
Paccapelo, Cinzia [2 ]
Zaninoni, Anna [1 ]
Zanella, Alberto [1 ]
机构
[1] Osped Maggiore Policlin, Fdn IRCCS Ca Granda, UO Ematol 2, I-20122 Milan, Italy
[2] Osped Maggiore Policlin, Fdn IRCCS Ca Granda, Ctr Trasfus & Immunoematol, I-20122 Milan, Italy
关键词
Anti-RBCs autoantibodies; Direct antiglobulin test; Autoimmune hemolytic anemia; HEMOLYTIC-ANEMIA; FLOW CYTOFLUOROMETRY; ANTIBODIES; COMPLEMENT;
D O I
10.1007/s12185-010-0578-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The diagnosis of autoimmune hemolytic anemia (AIHA) is based on a positive direct antiglobulin test (DAT), which is performed using various methods with different sensitivities. Recently, mitogen-stimulated (MS)-DAT was suggested to be able to identify latent anti-erythrocyte autoimmunity. Traditional methods (tube, microcolumn, and solid phase) and MS-DAT were compared in 54 consecutive cases of suspected AIHA, 28 idiopathic AIHA in clinical remission, and 12 difficult-to-diagnose cases of DAT-negative AIHA, and the results (all cases) were correlated with hematologic and hemolytic parameters. DAT tube was confirmed as the gold standard to diagnose AIHA since almost all positive cases showed hemolytic anemia and positive eluates; 10 out of 26 tube-negative cases were positive on microcolumn and solid phase antiglobulin tests, and 22 out of 26 using MS-DAT, although only half of them showed clear signs of hemolysis. Mitogen stimulation increased the amount of IgG bound to red blood cells in all groups; moreover, MS-DAT was the only positive test in 10 cases of AIHA, and mitogen stimulation facilitated the identification of autoantibody specificity in culture supernatants. We conclude that a battery of tests rather than a single test is useful for the diagnosis of AIHA, including MS-DAT as an additional test for selected cases, although the results have to be cautiously interpreted based on the overall clinical context.
引用
收藏
页码:762 / 769
页数:8
相关论文
共 21 条
  • [11] EVALUATION OF THE POLYETHYLENE-GLYCOL ANTIGLOBULIN-TEST FOR DETECTION OF RED-BLOOD-CELL ANTIBODIES
    DEMAN, AJM
    OVERBEEKE, MAM
    VOX SANGUINIS, 1990, 58 (03) : 207 - 210
  • [12] A DIRECT ENZYME-LINKED ANTIGLOBULIN-TEST FOR DETECTION OF RED-CELL AUTOANTIBODIES IN AUTOIMMUNE HEMOLYTIC-ANEMIA
    LEACH, M
    MEDICAL LABORATORY SCIENCES, 1984, 41 (03): : 232 - 237
  • [13] WEAK FALSE POSITIVE DIRECT ANTIGLOBULIN-TEST REACTIONS WITH POLYSPECIFIC ANTIGLOBULIN REAGENTS - LACK OF CORRELATION WITH RED-BLOOD-CELL-BOUND C3D
    NASONGKLA, M
    HUMMERT, J
    CHAPLIN, H
    TRANSFUSION, 1982, 22 (04) : 273 - 275
  • [14] Multiple loci are linked with anti-red blood cell antibody production in NZB mice - comparison with other phenotypes implies complex modes of action
    Lee, NJ
    Rigby, RJ
    Gill, H
    Boyle, JJ
    Fossati-Jimack, L
    Morley, BJ
    Vyse, TJ
    CLINICAL AND EXPERIMENTAL IMMUNOLOGY, 2004, 138 (01): : 39 - 46
  • [15] AN ISOTOPIC ANTIGLOBULIN-TEST FOR QUANTITATION OF ANTI-SHEEP RED-BLOOD-CELL ANTIBODIES OF INDIVIDUAL IG CLASSES IN MICE BEARING DIFFERENT IGCH HAPLOTYPES
    HABER, J
    WINN, HJ
    JOURNAL OF IMMUNOLOGICAL METHODS, 1982, 48 (01) : 61 - 74
  • [16] An Update on the Analysis of Patient Red Blood Cell (RBC)-Bound Immunoglobulins (Ig) in Suspected Negative Direct Antiglobulin Test (DAT) Autoimmune Hemolytic Anemia (AIHA) by Flow Cytometry (FC) and Capillary Tube (CT) Methods
    Beres, W. A.
    Singh, S.
    Nance, S. J.
    Olichney, J. J.
    Moolten, D. N.
    Borge, P. D.
    TRANSFUSION, 2015, 55 : 136A - 136A
  • [17] Direct antiglobulin test type, red blood cell distribution width, and estimated glomerular filtration rate for early prediction of in-hospital mortality of patients with COVID-19
    Chen, Fei
    Wang, Jing
    Jin, Xinhong
    Li, Bin
    Ying, Yili
    Zheng, Yufen
    Lu, Guoguang
    Li, Jun
    Shen, Bo
    COMPUTATIONAL AND STRUCTURAL BIOTECHNOLOGY JOURNAL, 2024, 24 : 484 - 492
  • [18] GenoQuick® MRSA test for the direct detection of MRSA in comparison with two culture methods (Brillance MRSA agar, Columbia blood agar)
    Steinmann, J.
    Buer, J.
    Rath, P. M.
    INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2008, 298 : 11 - 11
  • [19] Comparison of the performance of microtube column systems and solid-phase systems and the tube low-ionic-strength solution additive indirect antiglobulin test in the detection of red cell alloantibodies
    Weisbach, V.
    Kohnhaeuser, T.
    Zimmermann, R.
    Ringwald, J.
    Strasser, E.
    Zingsem, J.
    Eckstein, R.
    TRANSFUSION MEDICINE, 2006, 16 (04) : 276 - 284
  • [20] Comparing the Removal of IgG from Red Blood Cells (RBCs) by EDTA Glycine Acid (EGA) and Chloroquine Diphosphate (CDP) Measured by Flow Cytometry (FC), Tube and Gel Direct Antiglobulin Test (DAT) Methods
    Beres, W. A.
    Beauchamp, C. M.
    Nickle, P. A.
    Singh, S.
    Nance, S. J.
    TRANSFUSION, 2013, 53 : 181A - 181A