Renal cysts: Is attenuation artifactually increased on contrast-enhanced CT images?

被引:67
|
作者
Bae, KT [1 ]
Heiken, JP [1 ]
Siegel, CL [1 ]
Bennett, HF [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
computed tomography (CT); contrast enhancement; helical; kidney; CT; cysts;
D O I
10.1148/radiology.216.3.r00se14792
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine if the attenuation values of simple renal cysts are artifactually increased on contrast material-enhanced, clinically acquired spiral computed tomographic (CT) images. MATERIALS AND METHODS: Dual-phase renal spiral CT studies (5-mm collimation; pitch, 1.0) were retrospectively analyzed in 24 consecutive patients who had ultrasonographic (US) documentation of simple renal cysts. Forty-eight cysts were identified. The attenuation values of each cyst were measured on nonenhanced, cortical phase, and nephrographic phase images. The size and the location of each cyst in relation to the renal parenchyma were also recorded. RESULTS: The cysts were 0.6-10.8 cm in diameter (mean, 2.6 cm; SD, 2.0). The mean attenuation change in the cysts from nonenhanced to contrast-enhanced images was statistically significant in a comparison of cortical phase and nephrographic phase images (P < .01): +1.8 HU (SD, 3.8) for cortical phase and +3.6 HU (SD, 5.6) for nephrographic phase images. Renal cysts 1.0 cm or smaller showed a higher attenuation increase (mean, +4.0 HU for cortical phase and +11.0 HU for nephrographic phase). None of the renal cysts larger than 1.0 cm demonstrated an increase greater than 10 HU (mean, +1.4 HU for cortical phase and +2.3 HU for nephrographic phase). Intraparenchymal cysts showed higher mean attenuation changes than the exophytic cysts. CONCLUSION: Attenuation Values in the renal cysts increased artifactually on contrast-enhanced images, but this pseudoenhancement was not substantial and was less than 10 HU when the cyst was larger than 1.0 cm in diameter.
引用
收藏
页码:792 / 796
页数:5
相关论文
共 50 条
  • [21] Contrast-enhanced ultrasonography for evaluation of cystic renal mass: in comparison to contrast-enhanced CT and conventional ultrasound
    Xue, Li-Yun
    Lu, Qing
    Huang, Bei-Jian
    Ma, Jiao-Jiao
    Yan, Li-Xia
    Wen, Jie-Xian
    Wang, Wen-Ping
    ABDOMINAL IMAGING, 2014, 39 (06): : 1274 - 1283
  • [22] Contrast-enhanced ultrasonography for evaluation of cystic renal mass: in comparison to contrast-enhanced CT and conventional ultrasound
    Li-Yun Xue
    Qing Lu
    Bei-Jian Huang
    Jiao-Jiao Ma
    Li-Xia Yan
    Jie-Xian Wen
    Wen-Ping Wang
    Abdominal Imaging, 2014, 39 : 1274 - 1283
  • [23] Contrast-enhanced ultrasonography in the differential diagnosis of complex renal cysts and small renal masses
    Thiemann, Janine
    Clevert, Dirk-Andre
    ONKOLOGIE, 2023, 29 (07): : 571 - 580
  • [24] Prognostic significance of contrast-enhanced CT attenuation value in extrahepatic cholangiocarcinoma
    Yoshiki Asayama
    Akihiro Nishie
    Kousei Ishigami
    Yasuhiro Ushijima
    Yukihisa Takayama
    Daisuke Okamoto
    Nobuhiro Fujita
    Takao Ohtsuka
    Tomoharu Yoshizumi
    Shinichi Aishima
    Yoshinao Oda
    Hiroshi Honda
    European Radiology, 2017, 27 : 2563 - 2569
  • [25] Prognostic significance of contrast-enhanced CT attenuation value in extrahepatic cholangiocarcinoma
    Asayama, Yoshiki
    Nishie, Akihiro
    Ishigami, Kousei
    Ushijima, Yasuhiro
    Takayama, Yukihisa
    Okamoto, Daisuke
    Fujita, Nobuhiro
    Ohtsuka, Takao
    Yoshizumi, Tomoharu
    Aishima, Shinichi
    Oda, Yoshinao
    Honda, Hiroshi
    EUROPEAN RADIOLOGY, 2017, 27 (06) : 2563 - 2569
  • [26] Analysis of contrast-enhanced MR images to assess renal function
    N. Michoux
    J-P. Vallée
    A. Pechère-Bertschi
    X. Montet
    L. Buehler
    B. E. Van Beers
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2006, 19 : 167 - 179
  • [27] Analysis of contrast-enhanced MR images to assess renal function
    Michoux, N.
    Valee, J-P.
    Pechere-Bertschi, A.
    Montet, X.
    Buehler, L.
    Van Beers, B. E.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2006, 19 (04) : 167 - 179
  • [28] Segmentation of contrast enhanced CT images for attenuation correction of PET/CT data
    Qiao, F
    Yue, Y
    Pan, TS
    Clark, JW
    Mawlawi, O
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2686 - 2689
  • [29] Utility of Intraprocedural Contrast-Enhanced CT in Ablation of Renal Masses
    Grewal, Arleen
    Khera, Satinderpal Singh
    McGahan, John P.
    Wilson, Machelle
    Loehfelm, Thomas W.
    Dall'Era, Marc A.
    Evans, Christopher P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (01) : 122 - 128
  • [30] The characterization of small hypoattenuating renal masses on contrast-enhanced CT
    Patel, Neesha S.
    Poder, Liina
    Wang, Zhen J.
    Yeh, Benjamin M.
    Qayyum, Aliya
    Jin, Hua
    Coakley, Fergus V.
    CLINICAL IMAGING, 2009, 33 (04) : 295 - 300