Robust energy management for an on-grid hybrid hydrogen refueling and battery swapping station based on renewable energy

被引:30
|
作者
Xu, Xiao [1 ,2 ]
Hu, Weihao [2 ]
Liu, Wen [3 ]
Du, Yuefang [2 ]
Huang, Qi [2 ]
Chen, Zhe [4 ]
机构
[1] Sichuan Univ, Coll Elect Engn, Chengdu, Peoples R China
[2] Univ Elect Sci & Technol China, Sch Mech & Elect Engn, Chengdu, Peoples R China
[3] Univ Utrecht, Copernicus Inst Sustainable Dev, Princetonlaan 8a, NL-3584 CB Utrecht, Netherlands
[4] Aalborg Univ, Dept Energy Technol, Pontoppidanstraede 111, Aalborg, Denmark
关键词
Energy management; Hybrid hydrogen refueling/battery swapping station; Hydrogen-based vehicle; Battery electric vehicle; Renewable energy; Hybrid stochastic/distributionally robust optimization; OPTIMAL OPERATION; POWER; OPTIMIZATION; MICROGRIDS; STRATEGY; SYSTEM;
D O I
10.1016/j.jclepro.2021.129954
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The potential of renewable energy should be fully exploited in the transportation sector to achieve a cleaner production. Therefore, this paper proposes an on-grid hybrid hydrogen refueling and battery swapping station powered by wind energy. This novel concept can promote the development of low-carbon emission vehicles including hydrogen-based vehicle and battery electric vehicle. During the daily operation of the station, the multiple uncertainties may lead to a higher operational cost. To address this problem, a hybrid stochastic/distributionally robust optimization method is proposed to handle different uncertainties for the energy management problem. The first type of uncertainties can be depicted by a certain distribution, i.e. electricity price and wind power, which is processed by a stochastic optimization method. The second type of uncertainties is associated with human behaviors and is difficult to find its probability distribution, i.e. the hydrogen demand of hydrogen-based vehicles, so the second type is processed by a distributionally robust optimization method. The overall objective is to minimize the total operational cost of the station, which also considers the battery swapping station overstock punishment. Because a reasonable battery swapping scheduling can reduce the waiting time of users and operational cost of the station. The results indicate that the proposed method can effectively address the conservatism of solutions as its total operational cost is 4.4% lower than that of the hybrid stochastic/robust optimization method under a high confidence level.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] A Cost-Effective Energy Management Approach for On-Grid Charging of Plug-in Electric Vehicles Integrated with Hybrid Renewable Energy Sources
    Bilal, Mohd
    Bokoro, Pitshou N.
    Sharma, Gulshan
    Pau, Giovanni
    ENERGIES, 2024, 17 (16)
  • [22] A Systematic Approach to Improving Consumers' Comfort through on-Grid Renewable Energy Integration and Battery Storage
    Sharma, Ankit Kumar
    Doda, Devendra Kumar
    Soni, Bhanu Pratap
    Bansal, Ramesh C.
    Palwalia, Dheeraj Kumar
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2023,
  • [23] Hydrogen reduction-based energy management strategy of hybrid fuel cell/PV/battery/supercapacitor renewable energy system
    Rezk H.
    Fathy A.
    Journal of Energy Storage, 2024, 86
  • [24] Optimization of On-Grid Hybrid Renewable Energy System: A Case Study on Azad Jammu and Kashmir
    Shahzad, Mohsin
    Qadir, Arsalan
    Ullah, Noman
    Mahmood, Zahid
    Saad, Naufal Mohamad
    Ali, Syed Saad Azhar
    SUSTAINABILITY, 2022, 14 (10)
  • [25] Base Station Sleeping Strategy for On-Grid Energy Saving in Cellular Networks With Hybrid Energy Supplies in IoT Environment
    Wang, Heng
    Zhao, Zhenzhen
    Cheng, Xiaodong
    Ying, Jilai
    Qu, Jianhua
    Xu, Guangyin
    IEEE ACCESS, 2018, 6 : 45578 - 45589
  • [26] Analysis of MPPT Based Grid Connected Hybrid Renewable Energy System with Battery Backup
    Amir, Mohammad
    Srivastava, Sudhir Kumar
    2018 INTERNATIONAL CONFERENCE ON COMPUTING, POWER AND COMMUNICATION TECHNOLOGIES (GUCON), 2018, : 903 - 907
  • [27] Robust real-time energy management for a hydrogen refueling station using generative adversarial imitation learning
    Huy, Truong Hoang Bao
    Duy, Nguyen Thanh Minh
    Phu, Pham Van
    Le, Tien-Dat
    Park, Seongkeun
    Kim, Daehee
    APPLIED ENERGY, 2024, 373
  • [28] Long-term optimization based on PSO of a grid-connected renewable energy/battery/hydrogen hybrid system
    Garcia-Trivino, Pablo
    Llorens-Iborra, Francisco
    Garcia-Vazquez, Carlos A.
    Gil-Mena, Antonio J.
    Fernandez-Ramirez, Luis M.
    Jurado, Francisco
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (21) : 10805 - 10816
  • [29] An Implementation of Renewable Energy Based Grid Interactive Charging Station
    Verma, Anjeet
    Singh, Bhim
    2019 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO (ITEC), 2019,
  • [30] User Association for On-grid Energy Minimizing in HetNets with Hybrid Energy Supplies
    Shi, Fengli
    Sun, Kai
    Huang, Wei
    Wei, Yongfeng
    2018 IEEE 18TH INTERNATIONAL CONFERENCE ON COMMUNICATION TECHNOLOGY (ICCT), 2018, : 778 - 783