Sensitive and Selective Electrochemical Determination of L-Cysteine Based on Cerium Oxide Nanofibers Modified Screen Printed Carbon Electrode

被引:20
|
作者
Cao, Fei [1 ,2 ]
Dong, Qiuchen [3 ]
Li, Caolong [1 ]
Kwak, Dongwook [4 ]
Huang, Yikun [3 ]
Song, Donghui [3 ]
Lei, Yu [2 ]
机构
[1] China Pharmaceut Univ, Sch Sci, Key Lab Biomed Funct Mat, Nanjing 211198, Jiangsu, Peoples R China
[2] Univ Connecticut, Dept Chem & Biomol Engn, Storrs, CT 06269 USA
[3] Univ Connecticut, Dept Biomed Engn, Storrs, CT 06269 USA
[4] Univ Connecticut, Dept Mat Sci & Engn, 97 North Eagleville Rd, Storrs, CT 06269 USA
关键词
CeO2; nanofibers; electrocatalytic oxidation; L-cysteine; electrochemical sensor; electrospinning; FILM-MODIFIED ELECTRODE; REDUCED GRAPHENE OXIDE; PASTE ELECTRODE; ELECTROCATALYTIC OXIDATION; FOLIC-ACID; VOLTAMMETRIC DETERMINATION; CUO NANOPARTICLES; ASCORBIC-ACID; URIC-ACID; SENSOR;
D O I
10.1002/elan.201800008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel L-cysteine (CysH) electrochemical sensor based on CeO2 nanofibers (NFs) modified screen printed carbon electrodes (SPCEs) was developed. The morphology and the structure of the as-prepared CeO2 NFs were first characterized using scanning electron microscopy (SEM) and X-ray diffraction pattern (XRD), respectively. The electrochemical and electrocatalytic performances of the CeO2 NFs modified SPCEs were then evaluated using cyclic voltammetry and amperometry. Experimental results showed that the CeO2 NFs modified SPCEs possess excellent electrocatalytic activity toward the detection of CysH. Specifically, the developed electrochemical sensor demonstrated a high sensitivity of 120AmM(-1)cm(-2), a low detection limit of 20nM (signal to noise ratio of 3) and a wide linear range up to 200M for the determination of CysH, which are among the best values reported in literature. In addition, good selectivity and outstanding intra- and inter-electrode reproducibility have also been observed. Furthermore, the developed CysH sensor was applied to detect CysH spiked into human serum samples with remarkable accuracy. All these features indicate that CeO2 NFs hold great promise in the development of high performance electrochemical sensor for CysH.
引用
收藏
页码:1133 / 1139
页数:7
相关论文
共 50 条
  • [41] L-cysteine modified silver electrode and the determination of copper ions
    Bai, Y
    Cheng, T
    Li, JG
    Guo, SH
    Cao, QJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (03) : 383 - 383
  • [42] Sensitive electrochemical sensor based on nickel/PDDA/reduced graphene oxide modified screen-printed carbon electrode for nitrite detection
    Paisanpisuttisin, Aunyarut
    Poonwattanapong, Praewpitcha
    Rakthabut, Punnada
    Ariyasantichai, Paranee
    Prasittichai, Chaiya
    Siriwatcharapiboon, Wilai
    RSC ADVANCES, 2022, 12 (45) : 29491 - 29502
  • [43] Sensitive determination of catechol using a glassy carbon electrode modified with L-cysteine and ZnS:Ni/ZnS quantum dots
    Qu, Jianying
    Wang, Yong
    Dong, Ying
    Zhu, Zhuanying
    Xing, Huanhuan
    ANALYTICAL METHODS, 2015, 7 (01) : 260 - 265
  • [44] Voltammetric determination of dopamine in human serum and urine at a glassy carbon electrode modified by cysteic acid based on electrochemical oxidation of L-cysteine
    Wang, Chengyin
    Liu, Qingxiu
    Shao, Xiaoqiu
    Hu, Xiaoya
    ANALYTICAL LETTERS, 2007, 40 (04) : 689 - 704
  • [45] Electrochemical Sensor Based on a Modified Graphite Screen Printed Electrode for Amitriptyline Determination
    Surface Engineering and Applied Electrochemistry, 2022, 58 : 100 - 108
  • [46] β-Cyclodextrin-Functionalized Gold Nanoparticles/Poly(L-cysteine) Modified Glassy Carbon Electrode for Sensitive Determination of Metronidazole
    Gu, Yue
    Liu, Weilu
    Chen, Ruixue
    Zhang, Li
    Zhang, Zhiquan
    ELECTROANALYSIS, 2013, 25 (05) : 1209 - 1216
  • [47] Electrochemical Sensor Based on a Modified Graphite Screen Printed Electrode for Amitriptyline Determination
    Nasab, Zoheira Bagheri
    Nejad, Fariba Garkani
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2022, 58 (01) : 100 - 108
  • [48] SENSITIVE L-CYSTEINE AMPEROMETRIC SENSOR BASED ON A GLASSY CARBON ELECTRODE MODIFIED BY MnO2 NANOPARTICLES
    Liu, Suqin
    Luo, Tianxiong
    Li, Lin
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2013, 41 (04) : 382 - 393
  • [49] Electrochemical determination of diethylstilbestrol in livestock and poultry meats by L-cysteine/gold nanoparticles modified electrode
    Wu, Junquan
    Zhao, Xiaojuan
    Zou, Yuting
    Wu, Xiaochun
    Bai, Weidong
    Zeng, Xiaofang
    MICROCHEMICAL JOURNAL, 2021, 164
  • [50] Tailoring of L-cysteine conjugated chitosan carbon electrode for selective and sensitive monitor of copper in the water
    Gong, Sheng
    Liu, Xuhong
    Liao, Haiyan
    Lin, Xiaoqiang
    Huang, Qizhang
    Hasan, Murtaza
    Shu, Xugang
    Zhou, Xinhua
    Gunasekaran, Sundaram
    MATERIALS TODAY COMMUNICATIONS, 2023, 35