An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma

被引:6
|
作者
Zhang, Qiaoxuan [1 ,2 ]
Han, Liqiao [1 ]
Zheng, Songbai [3 ]
Ouyang, Fen [1 ]
Wu, Xiaobin [1 ]
Yan, Jun [1 ]
Zhan, Min [1 ]
Ke, Peifeng [1 ]
Zhuang, Junhua [1 ]
Huang, Xianzhang [1 ]
机构
[1] Guangzhou Univ Chinese Med, Affiliated Hosp 2, Dept Lab Med, Guangzhou 510120, Guangdong, Peoples R China
[2] Guangzhou Univ Chinese Med, Clin Med Coll 2, Guangzhou 510120, Guangdong, Peoples R China
[3] Fujian Huayin Med Lab Ctr, Xiamen 361101, Fujian, Peoples R China
关键词
Aldosterone; Reference measurement procedure; Tandem mass spectrometry; Clinical laboratory measurements;
D O I
10.1007/s00216-021-03405-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Accurate quantitation of aldosterone is clinically important in standardized testing for primary aldosteronism. The results are often variable when performed by clinical immunoassays. To standardize and ensure the accuracy of clinical systems, reference measurement procedures (RMPs) with higher metrological order are required. A simple and reliable isotope dilution LC-IDMS/MS-based measurement procedure for human plasma aldosterone has been developed. This method involved plasma spiked with a deuterium-labelled internal standard, equilibrated for 0.5 h, and extracted by liquid-liquid extraction (LLE) without derivatization. Aldosterone and its structural analogues were baseline separated with a C18-packed UHPLC column with gradient elution within 7 min. The signal intensity variability and measurement imprecision were reduced by bracketing calibration during plasma aldosterone value assignment. The limit of detection (LoD) was 19.4 pmol/L with a signal-to-noise ratio (S/N) > 3. The lowest limit of quantification (LLoQ) was 27.7 pmol/L (S/N > 10 and CV < 10.0%). LLE was performed with 1 mL of n-hexane/ethyl acetate (3:2, v/v), and the extraction recovery was determined to be 92.15 +/- 3.54%. The imprecisions were <= 3.18% for samples at 124.8, 867.0, and 2628.5 pmol/L. The recoveries were 98.11-101.61%. The relative bias between this candidate RMP and the established RMP was 2.76-1.89%. The linearity response ranged from 27.7 to 2774.4 pmol/L with R-2 = 0.999. The method performance met the requirements of RMPs (<= 5% total CV and <= 3% bias). Furthermore, the developed method was applied to evaluate immunoassays through 41 patient sample comparisons. The calibration and measurement capability (CMC) of this method were also evaluated by measuring these samples. The candidate RMP can serve as an accurate reference baseline for routine methods and can be used for value assignment for reference materials.
引用
收藏
页码:4471 / 4481
页数:11
相关论文
共 50 条
  • [41] Development and evaluation of a candidate reference measurement procedure for detecting 17α-hydroxyprogesterone in dried blood spots using isotope dilution liquid chromatography tandem mass spectrometry
    He, Ziyun
    Dai, Haibing
    Shen, Jian
    Huang, Yanjie
    Liu, Jinsong
    Yan, Renqing
    Zhang, Feng
    Yan, Shengkai
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (20) : 4635 - 4645
  • [42] Measurement of serum progesterone by isotope dilution liquid chromatography tandem mass spectrometry: a candidate reference method and its application to evaluating immunoassays
    Yufei Wang
    Tianjiao Zhang
    Haijian Zhao
    Weiyan Zhou
    Jie Zeng
    Jiangtao Zhang
    Chuanbao Zhang
    Wenxiang Chen
    Analytical and Bioanalytical Chemistry, 2019, 411 : 2363 - 2371
  • [43] Measurement of serum progesterone by isotope dilution liquid chromatography tandem mass spectrometry: a candidate reference method and its application to evaluating immunoassays
    Wang, Yufei
    Zhang, Tianjiao
    Zhao, Haijian
    Zhou, Weiyan
    Zeng, Jie
    Zhang, Jiangtao
    Zhang, Chuanbao
    Chen, Wenxiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (11) : 2363 - 2371
  • [44] Clinical Evaluation of Assays for Plasma Renin Activity and Aldosterone Measurement by Liquid Chromatography-Tandem Mass Spectrometry
    Gibbons, Stephen M.
    Field, Helen P.
    Fairhurst, April
    Fleming, Anne
    Ford, Clive
    Williams, Emma L.
    Barnes, Sophie C.
    Barth, Julian H.
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2021, 6 (03): : 668 - 678
  • [45] Measurement of urea in human serum by isotope dilution mass spectrometry: A reference procedure
    Kessler, A
    Siekmann, L
    CLINICAL CHEMISTRY, 1999, 45 (09) : 1523 - 1529
  • [46] State-of-the-art of serum testosterone measurement by isotope dilution-liquid chromatography-tandem mass spectrometry
    Thienpont, Linda M.
    Van Uytfanghe, Katleen
    Blincko, Stuart
    Ramsay, Carol S.
    Xie, Hui
    Doss, Robert C.
    Keevil, Brian G.
    Owen, Laura J.
    Rockwood, Alan L.
    Kushnir, Mark M.
    Chun, Kelly Y.
    Chandler, Donald W.
    Field, Helen P.
    Sluss, Patrick M.
    CLINICAL CHEMISTRY, 2008, 54 (08) : 1290 - 1297
  • [47] Measurement of Urinary Total Desmosine and Isodesmosine Using Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry
    Albarbarawi, Osama
    Barton, Alun
    Lin, ZhaoSheng
    Takahashi, Eddie
    Buddharaju, Ajay
    Brady, Jeffrey
    Miller, Douglas
    Palmer, Colin N. A.
    Huang, Jeffrey T. -J.
    ANALYTICAL CHEMISTRY, 2010, 82 (09) : 3745 - 3750
  • [48] Evaluation of an Isotope Dilution HPLC Tandem Mass Spectrometry Candidate Reference Measurement Procedure for Total 17-β Estradiol in Human Serum
    Botelho, Julianne Cook
    Ribera, Ashley
    Cooper, Hans C.
    Vesper, Hubert W.
    ANALYTICAL CHEMISTRY, 2016, 88 (22) : 11123 - 11129
  • [49] Measurement of tamsulosin in human serum by liquid chromatography-tandem mass spectrometry
    Upreti, Rita
    Homer, Natalie Z. M.
    Naredo, Gregorio
    Cobice, Diego F.
    Hughes, Katherine A.
    Stewart, Laurence H.
    Walker, Brian R.
    Andrew, Ruth
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 930 : 121 - 128
  • [50] Measurement of Sufentanil in Human Milk by Liquid Chromatography-Tandem Mass Spectrometry
    Huang, Yangfa
    Liao, Lianming
    Zeng, Manlin
    Huang, Qijian
    Zeng, Jian
    Zhang, Liangcheng
    JOURNAL OF BIOBASED MATERIALS AND BIOENERGY, 2023, 17 (04) : 492 - 497