摘要
A comparison is presented between experimental and numerical results regarding the operation of a capillary pumped loop evaporator. Two cylindrical evaporators were tested, with different heated porous lengths, 20 and 40 mm, respectively. Both have 22 mm external diameter, 9 mm porous thickness and 80 mm porous length. The working liquid was water. The loop was made from copper tubes and the evaporator from copper porous wick covered with aluminum with grooves formed in the inner surface. All tests took place on a horizontal level using heat load applied to the evaporator surface from an 85-W electric resistance. The experimental measurements were compared with the predictions of a three-dimensional CFD model of the evaporator and were found to be in satisfactory agreement. For the 20-mm wick heated length evaporator CFD model with water initial temperature of 20 degrees C the divergence with the experimental pressure drop mean value was 0 Pa for volume flow rates between 0.4 and 0.6 l/min and 50 Pa for the rest of the values. For 30 degrees C the divergence was 0 Pa,0.4 l/min and 50 Pa for larger flow rates. Moreover, for 40 degrees C the difference was up to 50 Pa from 0 to 0.9 l/min. In every case predictions were below the wick capillary limit. The computed outflow temperature presented a maximum difference of 1.5% compared with the experimental data, which is very satisfying. On the other hand, the predictions of the evaporator CFD model with a 40-mm wick heated length were even better.
引用
收藏
页码:184 / 192
页数:9
相关论文
共 50 条
  • [1] Experimental study of small scale capillary pumped loop
    Chen, Pin-Chih
    Lin, Wei-Keng
    Zhongguo Hangkong Taikong Xuehui Huikan/Transactions of the Aeronautical and Astronautical Society of the Republic of China, 2001, 33 (02): : 103 - 109
  • [2] EXPERIMENTAL AND ANALYTICAL INVESTIGATION OF A CAPILLARY PUMPED LOOP
    DICKEY, JT
    PETERSON, GP
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1994, 8 (03) : 602 - 607
  • [3] Experimental study on the operating characteristics of a capillary pumped loop with a flat evaporator
    Joung, Wukchul
    Hwang, Hyungjin
    Lee, Jinho
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (1-3) : 268 - 275
  • [4] Experimental study of capillary pumped loop for integrated power in gravity field
    Lachassagne, Laurent
    Ayel, Vincent
    Romestant, Cyril
    Bertin, Yves
    APPLIED THERMAL ENGINEERING, 2012, 35 : 166 - 176
  • [5] Experimental Analysis of a Capillary Pumped Loop for Terrestrial Application
    Ayel, Vincent
    Lachassagne, Laurent
    Bertin, Yves
    Romestant, Cyril
    Lossouarn, David
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2011, 25 (04) : 561 - 571
  • [6] An experimental investigation on capillary pumped loop with the meshes wick
    Yu, Jianlin
    Chen, Hua
    Zhao, Hua
    Li, Yanzhong
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (21-22) : 4503 - 4507
  • [7] Experimental investigation of a neon cryogenic capillary pumped loop
    Bugby, DC
    Kroliczek, EJ
    Cullimore, BA
    Baumann, JE
    IECEC-97 - PROCEEDINGS OF THE THIRTY-SECOND INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE, VOLS 1-4: VOL.1: AEROSPACE POWER SYSTEMS AND TECHNOL; VOL 2: ELECTROCHEMICAL TECHNOL, CONVERSION TECHNOL, THERMAL MANAGEMENT; VOLS 3: ENERGY SYSTEMS, RENEWABLE ENERGY RESOURCES, ENVIRONMENTAL IMPACT, POLICY IMPACTS ON ENERGY; VOL 4: POST DEADLINE PAPERS, INDEX, 1997, : 1403 - 1408
  • [8] Experimental and analytical study of a reversible two-phase capillary pumped loop
    Hustaix, H
    Maciaszek, T
    Puillet, C
    SIXTH EUROPEAN SYMPOSIUM ON SPACE ENVIRONMENTAL CONTROL SYSTEMS, VOLS 1 AND 2, 1997, 400 : 411 - 417
  • [9] An experimental feasibility study on EHD-assisted capillary pumped loop (CPL)
    Ohadi, MM
    Dessiatoun, SV
    Mo, BJ
    Kim, JH
    Cheung, K
    Didion, J
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM, PTS 1-3: 1ST CONFERENCE ON FUTURE SCIENCE & EARTH SCIENCE MISSIONS; 1ST CONFERENCE ON SYNERGISTIC POWER & PROPULSION SYSTEMS TECHNOLOGY; 1ST CONFERENCE ON APPLICATIONS OF THERMOPHYSICS IN MICROGRAVITY; 2ND CONFERENCE ON COMMERCIAL DEVELOPMENT OF SPACE; - 2ND CONFERENCE ON NEXT GENERATION LAUNCH SYSTEMS; 14TH SYMPOSIUM ON SPACE NUCLEAR POWER AND PROPULSION, 1997, (387): : 567 - 572
  • [10] Experimental study of a Capillary Pumped Loop assisted with a mechanical pump placed at the evaporator inlet
    Leveque, Marie
    Dutour, Sebastien
    Lluc, Jacques
    Lavieille, Pascal
    Miscevic, Marc
    Bertin, Yves
    Mari, Raphael
    Fourgeaud, Laura
    APPLIED THERMAL ENGINEERING, 2020, 169