High-resolution dental magnetic resonance imaging of inferior alveolar nerve responses to the extraction of third molars

被引:26
|
作者
Kress, B
Gottschalk, A
Anders, L
Stippich, C
Palm, F
Bähren, W
Sartor, K
机构
[1] Heidelberg Univ, Med Ctr, Dept Neurol, Div Neuroradiol, D-69120 Heidelberg, Germany
[2] Armed Forces Hosp, Dept Radiol, Ulm, Germany
[3] Armed Forces Hosp, Dept Dent Oral & Maxillofacial Surg, Ulm, Germany
关键词
dental MRI; osteotomy; inferior alveolar nerve;
D O I
10.1007/s00330-004-2285-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to assess whether signal changes can be detected in the neurovascular bundle of the mandibular canal after the extraction of a third molar. We retrospectively analyzed MRI scans of 30 test subjects with healthy mandibles and 41 patients who had had a wisdom tooth extracted. Signal intensities were measured at particular sites in the neurovascular bundle, which were defined as regions of interest (ROI) in the sagittal T1-weighted images before and after intravenous administration of a paramagnetic contrast agent. On the basis of the signal intensity increases that were measured after contrast agent administration, we compared the signal increases obtained for the patients who had received surgical treatment with the results obtained for the population of test subjects with unremarkable mandibles (t-test, P<0.05). Compared with the healthy test subjects, patients who had received surgical treatment showed significantly higher signal intensity increases at two measurement sites, i.e., the second molar and the second premolar (P<0.05). We found no significant differences when the measurements were performed at the first molar (P=0.06), the third molar (P=0.47) and in the area of the ascending mandibular ramus (P=0.79). Compared with a population of healthy test subjects, patients who had their third molars surgically removed show higher signal intensity increases in the neurovascular bundle after intravenous contrast agent administration. The underlying cause may be the higher blood flow in the arteries and veins and the perineural plexus, which may give evidence of the pathophysiological mechanism of nerve damage in the narrow canal as a result of osteotomy.
引用
收藏
页码:1416 / 1420
页数:5
相关论文
共 50 条
  • [41] Cochlear Nerve Diameter in Normal Hearing Ears Using High-Resolution Magnetic Resonance Imaging
    Jaryszak, Eric M.
    Patel, Nimish A.
    Camp, Morgan
    Mancuso, Anthony A.
    Antonelli, Patrick J.
    LARYNGOSCOPE, 2009, 119 (10): : 2042 - 2045
  • [42] New quantitative classification of the anatomical relationship between impacted third molars and the inferior alveolar nerve
    Wang, Wei-Quan
    Chen, Michael Y. C.
    Huang, Heng-Li
    Fuh, Lih-Jyh
    Tsai, Ming-Tzu
    Hsu, Jui-Ting
    BMC MEDICAL IMAGING, 2015, 15
  • [43] High-resolution ultrasound and magnetic resonance imaging of ulnar nerve neuropathy in the distal Guyon tunnel
    Picasso, Riccardo
    Zaottini, Federico
    Pistoia, Federico
    Maccio, Marta
    Rossi, Gabriele
    Cabona, Corrado
    Benedetti, Luana
    Martinoli, Carlo
    INSIGHTS INTO IMAGING, 2023, 14 (01)
  • [44] New quantitative classification of the anatomical relationship between impacted third molars and the inferior alveolar nerve
    Wei-Quan Wang
    Michael Y. C. Chen
    Heng-Li Huang
    Lih-Jyh Fuh
    Ming-Tzu Tsai
    Jui-Ting Hsu
    BMC Medical Imaging, 15
  • [45] Inferior Alveolar Nerve Deficits and Recovery Following Surgical Removal of Impacted Mandibular Third Molars
    Bhat P.
    Cariappa K.M.
    Journal of Maxillofacial and Oral Surgery, 2012, 11 (3) : 304 - 308
  • [46] Coronectomy is an effective strategy for treating impacted third molars in close proximity to the inferior alveolar nerve
    Geisler, Stacy
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2013, 144 (10): : 1172 - 1173
  • [47] Distribution and Absorption of Local Anesthetics in Inferior Alveolar Nerve Block: Evaluation by Magnetic Resonance Imaging
    Ay, Sinan
    Kucuk, Dervishan
    Gumus, Cesur
    Kara, M. Isa
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (11) : 2722 - 2730
  • [48] Magnetic Resonance Imaging Finding of Periodontal and Inferior Alveolar Nerve Inflammation in a Subject With Trigeminal Neuralgia
    Laroni, Alice
    Signorini, Giuseppe
    Caserta, Michela
    Canevari, Maria
    HEADACHE, 2020, 60 (10): : 2631 - 2632
  • [49] Inferior Alveolar Nerve Block Using the Anterior Technique to Anesthetize Buccal Nerve and Improve Anesthesia Success Rates for Third Molar Extraction: A Randomized Controlled Trial and Magnetic Resonance Imaging Evaluation
    Tsukimoto, Shota
    Takasugi, Yoshihiro
    Aoki, Risa
    Kimura, Motoshi
    Konishi, Tatsuo
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 77 (10) : 2004 - 2016
  • [50] Visual responses of the human superior colliculus: A high-resolution functional magnetic resonance imaging study
    Schneider, KA
    Kastner, S
    JOURNAL OF NEUROPHYSIOLOGY, 2005, 94 (04) : 2491 - 2503