Compact CMOS active quenching/recharge circuit for SPAD arrays

被引:9
|
作者
Vornicu, Ion [1 ]
Carmona-Galan, Ricardo [1 ]
Perez-Verdu, Belen [1 ]
Rodriguez-Vazquez, Angel [1 ]
机构
[1] Univ Seville, CSIC, CNM, Inst Microelect Sevilla, Ave Amer Vespucio S-N,Parque Cientif & Tecnol Car, Seville 41092, Spain
关键词
active quenching; recharge (AQR) circuit; tunable dead time; single-photon avalanche diode (SPAD); Geiger mode; afterpulsing reduction; PHOTON AVALANCHE-DIODE;
D O I
10.1002/cta.2113
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Avalanche diodes operating in Geiger mode are able to detect single photon events. They can be employed to photon counting and time-of-flight estimation. In order to ensure proper operation of these devices, the avalanche current must be rapidly quenched, and, later on, the initial equilibrium must be restored. In this paper, we present an active quenching/recharge circuit specially designed to be integrated in the form of an array of single-photon avalanche diode (SPAD) detectors. Active quenching and recharge provide benefits like an accurately controllable pulse width and afterpulsing reduction. In addition, this circuit yields one of the lowest reported area occupations and power consumptions. The quenching mechanism employed is based on a positive feedback loop that accelerates quenching right after sensing the avalanche current. We have employed a current starved inverter for the regulation of the hold-off time, which is more compact than other reported controllable delay implementations. This circuit has been fabricated in a standard 0.18 mu m complementary metal-oxide-semiconductor (CMOS) technology. The SPAD has a quasi-circular shape of 12 mu m diameter active area. The fill factor is about 11%. The measured time resolution of the detector is 187ps. The photon-detection efficiency (PDE) at 540nm wavelength is about 5% at an excess voltage of 900mV. The break-down voltage is 10.3V. A dark count rate of 19kHz is measured at room temperature. Worst case post-layout simulations show a 117ps quenching and 280ps restoring times. The dead time can be accurately tuned from 5 to 500ns. The pulse-width jitter is below 1.8ns when dead time is set to 40ns. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:917 / 928
页数:12
相关论文
共 50 条
  • [31] Time-resolved CMOS SPAD arrays: architectures, applications and perspectives
    Villa, Federica
    Lussana, Rudi
    Portaluppi, Davide
    Tosi, Alberto
    Zappa, Franco
    [J]. ADVANCED PHOTON COUNTING TECHNIQUES XI, 2017, 10212
  • [32] A 150nm fully integrated active quenching circuit driving custom technology SPAD at 250Mcps
    Giudici, Andrea
    Acconcia, Giulia
    Labanca, Ivan
    Ghioni, Massimo
    Rech, Ivan
    [J]. EMERGING IMAGING AND SENSING TECHNOLOGIES FOR SECURITY AND DEFENCE VII, 2022, 12274
  • [33] Resource sharing in CMOS SPAD arrays: application requirements and design solutions
    Pancheri, Lucio
    [J]. 2019 26TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS (ICECS), 2019, : 803 - 806
  • [34] STANDARD CMOS INTEGRATED ULTRA-COMPACT MICROMECHANICAL OSCILLATING ACTIVE PIXEL ARRAYS
    Bhosale, Kalyani
    Chen, Chao-Yu
    Li, Ming-Huang
    Li, Sheng-Shian
    [J]. 2021 34TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2021), 2021, : 157 - 160
  • [35] A QUENCHING CIRCUIT FOR SELF-QUENCHING GEIGER-MULLER ARRAYS
    CAINI, V
    OLSSON, IU
    [J]. ARKIV FOR FYSIK, 1962, 22 (03): : 225 - 235
  • [36] Active quenching circuit with adjustable reverse bias voltage for single photon avalanche diodes arrays
    Zheng Lixia
    Hu Kang
    Wu Jin
    Sun Weifeng
    [J]. SEVENTH ASIA PACIFIC CONFERENCE ON OPTICS MANUFACTURE (APCOM 2021), 2022, 12166
  • [37] ANALOG CIRCUIT IMPLEMENTATION ON CMOS SEMICUSTOM ARRAYS
    DUCHENE, PP
    DECLERCQ, MJ
    GOFFART, B
    NOVAK, M
    [J]. IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1993, 28 (07) : 872 - 874
  • [38] Enhancing the fill-factor of CMOS SPAD arrays using microlens integration
    Intermite, G.
    Warburton, R. E.
    McCarthy, A.
    Ren, X.
    Villa, F.
    Waddie, A. J.
    Taghizadeh, M. R.
    Zou, Y.
    Zappa, F.
    Tosi, A.
    Buller, G. S.
    [J]. PHOTON COUNTING APPLICATIONS 2015, 2015, 9504
  • [39] Time resolved photon counting CMOS SPAD arrays for clinical imaging and spectroscopy
    Tanner, M. G.
    [J]. TRANSLATIONAL BIOPHOTONICS: DIAGNOSTICS AND THERAPEUTICS III, 2023, 12627
  • [40] Compact calibration circuit for large neuromorphic arrays
    Lenero-Bardallo, Juan A.
    Serrano-Gotarredona, Teresa
    Linares-Barranco, Bernabe
    [J]. PROCEEDINGS OF 2008 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-10, 2008, : 1776 - +