Penetration of airborne microorganisms through a surgical mask and a dust/mist respirator

被引:64
|
作者
Willeke, K
Qian, YG
Donnelly, J
Grinshpun, S
Ulevicius, V
机构
[1] Aerosol Res. and Resp. Protect. Lab., Department of Environmental Health, University of Cincinnati, Cincinnati
[2] Institute of Physics, Vilnius
来源
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL | 1996年 / 57卷 / 04期
关键词
aerodynamic size spectrometer; bacterial penetration; Mycobacterium tuberculosis; respirator; efficiency; microorganism;
D O I
10.1080/15428119691014882
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigated bacterial penetration of different bacterial shapes, aerodynamic sizes, and flow rates through a surgical mask and a dust/mist respirator. The bacterial penetrations were compared with those of spherical corn oil particles of the same aerodynamic diameter tested under the same conditions. The tests were performed at different levels of aerosol penetration. Bacteria, ranging from spherical to rod-shaped with a high aspect (length to width) ratio, were selected as test agents. Among these, Pseudomonas fluorescens physically simulates Mycobacterium tuberculosis by shape and size. The concentrations of bacteria upstream and downstream of the test devices were measured with an aerodynamic size spectrometer. This instrument was found to measure the total viable and nonviable bacterial concentration effectively and dynamically over the entire bacterial size range down to 0.5 mu m in aerodynamic size. The results indicate that the spherical corn oil particles and the spherical Streptococcus salivarius bacteria have the same penetration in the size range from 0.9 to 1.7 mu m it has been found that rod-shaped bacteria penetrate less. The penetration difference between the spherical and rod-shaped bacteria depends on the aspect ratio of the bacteria. For an aspect ratio of 4, the penetration of rod-shaped bacteria is about ha If that of spherical ones. Thus, it is projected that a respirator with 90% efficiency against spherical microorganisms or test particles (10% penetration) will be 95% efficient against rod-shaped microorganisms of the same aerodynamic equivalent diameter with an aspect ratio of 3 to 4, such as Mycobacterium tuberculosis (5% penetration).
引用
收藏
页码:348 / 355
页数:8
相关论文
共 50 条
  • [21] N95 respirator and surgical mask in the pandemic of COVID-19
    Sureka, Binit
    Garg, Mahendra Kumar
    Misra, Sanjeev
    ANNALS OF THORACIC MEDICINE, 2020, 15 (04) : 247 - 248
  • [22] Physiological Impacts of Surgical Mask Coverage of Elastomeric Half-mask Respirator Exhalation Valves in Healthcare Workers
    Zhuang, Eileen
    Thurman, Paul
    Chen, Hegang H.
    McDiarmid, Melissa A.
    Hines, Stella E.
    ANNALS OF WORK EXPOSURES AND HEALTH, 2022, 66 (02) : 233 - 245
  • [23] Method for measuring the spatial variability of aerosol penetration through respirator filters
    Huang, CL
    Willeke, K
    Qian, YG
    Grinshpun, S
    Ulevicius, V
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1998, 59 (07): : 461 - 465
  • [24] Effect of an electrostatic space charge system on airborne dust and subsequent potential transmission of microorganisms to broiler breeder pullets by airborne dust
    Richardson, LJ
    Mitchell, BW
    Wilson, JL
    Hofacre, CL
    AVIAN DISEASES, 2003, 47 (01) : 128 - 133
  • [25] Exposure to airborne microorganisms, dust and endotoxin during flax scutching on farms
    Krysinska-Traczyk, E
    Skórska, C
    Prazmo, Z
    Sitkowska, J
    Cholewa, G
    Dutkiewicz, J
    ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2004, 11 (02) : 309 - 317
  • [26] Microorganisms and volatile organic compounds in airborne dust from damp residences
    Nilsson, A
    Kihlström, E
    Lagesson, V
    Wessén, B
    Szponar, B
    Larsson, L
    Tagesson, C
    INDOOR AIR, 2004, 14 (02) : 74 - 82
  • [27] Recognizing the Type of Mask or Respirator Worn Through a CNN Trained with a Novel Database
    Marceddu, Antonio Costantino
    Montrucchio, Bartolomeo
    2021 IEEE 45TH ANNUAL COMPUTERS, SOFTWARE, AND APPLICATIONS CONFERENCE (COMPSAC 2021), 2021, : 1490 - 1495
  • [28] CONTAMINATION OF MILK WITH AIRBORNE MICROORGANISMS THROUGH VACUUM DEFOAMER
    CANNON, RY
    REDDY, KK
    JOURNAL OF MILK AND FOOD TECHNOLOGY, 1970, 33 (05): : 197 - &
  • [29] PENETRATION OF METHYL ISOCYANATE THROUGH ORGANIC VAPOR AND ACID GAS RESPIRATOR CARTRIDGES
    MOYER, ES
    BERARDINELLI, SP
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1987, 48 (04): : 315 - 323
  • [30] Exposure to dust, endotoxin and airborne microorganisms in wastewater sludge thermal drying units
    Schlosser, O.
    Huyard, A.
    Catalan, V.