Partial discharge localization in power transformers based on the sequential quadratic programming-genetic algorithm adopting acoustic emission techniques

被引:12
|
作者
Liu, Hua-Long [1 ]
Liu, Hua-Dong [2 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] Beijing Univ Posts & Telecommun, Inst Network Technol, Beijing 100876, Peoples R China
来源
关键词
Acoustic emission testing - Genetic algorithms - Ultrasonic testing - Power transformers - Partial discharges;
D O I
10.1051/epjap/2014140318
中图分类号
O59 [应用物理学];
学科分类号
摘要
Partial discharge (PD) in power transformers is one of the prime reasons resulting in insulation degradation and power faults. Hence, it is of great importance to study the techniques of the detection and localization of PD in theory and practice. The detection and localization of PD employing acoustic emission (AE) techniques, as a kind of non-destructive testing, plus due to the advantages of powerful capability of locating and high precision, have been paid more and more attention. The localization algorithm is the key factor to decide the localization accuracy in AE localization of PD. Many kinds of localization algorithms exist for the PD source localization adopting AE techniques including intelligent and non-intelligent algorithms. However, the existed algorithms possess some defects such as the premature convergence phenomenon, poor local optimization ability and unsuitability for the field applications. To overcome the poor local optimization ability and easily caused premature convergence phenomenon of the fundamental genetic algorithm (GA), a new kind of improved GA is proposed, namely the sequence quadratic programming-genetic algorithm (SQP-GA). For the hybrid optimization algorithm, SQP-GA, the sequence quadratic programming (SQP) algorithm which is used as a basic operator is integrated into the fundamental GA, so the local searching ability of the fundamental GA is improved effectively and the premature convergence phenomenon is overcome. Experimental results of the numerical simulations of benchmark functions show that the hybrid optimization algorithm, SQP-GA, is better than the fundamental GA in the convergence speed and optimization precision, and the proposed algorithm in this paper has outstanding optimization effect. At the same time, the presented SQP-GA in the paper is applied to solve the ultrasonic localization problem of PD in transformers, then the ultrasonic localization method of PD in transformers based on the SQP-GA is proposed. And localization results based on the SQP-GA are compared with some algorithms such as the GA, some other intelligent and non-intelligent algorithms. The results of calculating examples both stimulated and spot experiments demonstrate that the localization method based on the SQP-GA can effectively prevent the results from getting trapped into the local optimum values, and the localization method is of great feasibility and very suitable for the field applications, and the precision of localization is enhanced, and the effectiveness of localization is ideal and satisfactory.
引用
收藏
页码:618 / 621
页数:16
相关论文
共 48 条
  • [31] Performance analysis of acoustic sensors based time reversal technique for partial discharge localization in power transformers (vol 215, 108965, 2023)
    Rathod, Viral B.
    Kumbhar, Ganesh B.
    Bhalja, Bhavesh R.
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 217
  • [32] Passive shimming optimization method of MRI based on genetic algorithm-sequential quadratic programming
    Zhao J.
    Liu F.
    Xia L.
    Fan Y.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2024, 58 (06): : 1305 - 1314
  • [33] Application of Sequential Quadratic Programming Algorithm based on region search method in reactive power optimization
    Ma, Yongfei
    Wang, Xianmin
    2006 3RD INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING, 2006, : 285 - +
  • [34] Computer-based acoustic emission detecting instrument for partial discharge within power capacitor
    Gao, S.Y.
    Zhang, L.
    Tan, K.X.
    Li, F.Q.
    Fu, X.T.
    Gaodianya Jishu/High Voltage Engineering, 2001, 27 (04):
  • [35] A Novel Method for Ultra-High-Frequency Partial Discharge Localization in Power Transformers Using the Particle Swarm Optimization Algorithm
    Mirzaei, Hasan Reza
    Akbari, Asghar
    Gockenbach, Ernst
    Zanjani, Mojtaba
    Miralikhani, Karim
    IEEE ELECTRICAL INSULATION MAGAZINE, 2013, 29 (02) : 26 - 39
  • [36] Elastic stress solution for complex cross section of roadways based on genetic optimization and sequential quadratic programming algorithm
    Hu B.
    Li C.
    Wei X.
    Zhou X.
    Gong C.
    Wang D.
    Li, Changhong (li_chang_hongustb@163.com), 1600, Academia Sinica (36): : 407 - 419
  • [37] On-Line Partial Discharge Monitoring System for Power Transformers Based on the Simultaneous Detection of High Frequency, Ultra-High Frequency, and Acoustic Emission Signals
    Sikorski, Wojciech
    Walczak, Krzysztof
    Gil, Wieslaw
    Szymczak, Cyprian
    ENERGIES, 2020, 13 (12)
  • [38] Single-Sensor Based Acoustic Time Reversal Technique for Partial Discharge Localization in Power Transformer
    Rathod, Viral B.
    Kumbhar, Ganesh B.
    Bhalja, Bhavesh R.
    PROCEEDINGS OF 2021 5TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (IEEE CATCON 2021), 2021, : 151 - 156
  • [39] Arrival time estimation methodology for partial discharge acoustic signals in power transformers based on a double-threshold technique
    Wang, Yan-Bo
    Fan, Yu-Hang
    Qin, Shao-Rui
    Chang, Ding-Ge
    Shao, Xian-Jun
    Mu, Hai-Bao
    Zhang, Guan-Jun
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (02)
  • [40] Research on Optimal Scheduling of Integrated Energy System in Highway Service Area Based on a Genetic Algorithm-Sequential Quadratic Programming Algorithm
    Li J.
    Gao S.
    Yuan B.
    Zhang Y.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2024, 58 (05): : 200 - 211