Partial discharge localization in power transformers based on the sequential quadratic programming-genetic algorithm adopting acoustic emission techniques

被引:12
|
作者
Liu, Hua-Long [1 ]
Liu, Hua-Dong [2 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] Beijing Univ Posts & Telecommun, Inst Network Technol, Beijing 100876, Peoples R China
来源
关键词
Acoustic emission testing - Genetic algorithms - Ultrasonic testing - Power transformers - Partial discharges;
D O I
10.1051/epjap/2014140318
中图分类号
O59 [应用物理学];
学科分类号
摘要
Partial discharge (PD) in power transformers is one of the prime reasons resulting in insulation degradation and power faults. Hence, it is of great importance to study the techniques of the detection and localization of PD in theory and practice. The detection and localization of PD employing acoustic emission (AE) techniques, as a kind of non-destructive testing, plus due to the advantages of powerful capability of locating and high precision, have been paid more and more attention. The localization algorithm is the key factor to decide the localization accuracy in AE localization of PD. Many kinds of localization algorithms exist for the PD source localization adopting AE techniques including intelligent and non-intelligent algorithms. However, the existed algorithms possess some defects such as the premature convergence phenomenon, poor local optimization ability and unsuitability for the field applications. To overcome the poor local optimization ability and easily caused premature convergence phenomenon of the fundamental genetic algorithm (GA), a new kind of improved GA is proposed, namely the sequence quadratic programming-genetic algorithm (SQP-GA). For the hybrid optimization algorithm, SQP-GA, the sequence quadratic programming (SQP) algorithm which is used as a basic operator is integrated into the fundamental GA, so the local searching ability of the fundamental GA is improved effectively and the premature convergence phenomenon is overcome. Experimental results of the numerical simulations of benchmark functions show that the hybrid optimization algorithm, SQP-GA, is better than the fundamental GA in the convergence speed and optimization precision, and the proposed algorithm in this paper has outstanding optimization effect. At the same time, the presented SQP-GA in the paper is applied to solve the ultrasonic localization problem of PD in transformers, then the ultrasonic localization method of PD in transformers based on the SQP-GA is proposed. And localization results based on the SQP-GA are compared with some algorithms such as the GA, some other intelligent and non-intelligent algorithms. The results of calculating examples both stimulated and spot experiments demonstrate that the localization method based on the SQP-GA can effectively prevent the results from getting trapped into the local optimum values, and the localization method is of great feasibility and very suitable for the field applications, and the precision of localization is enhanced, and the effectiveness of localization is ideal and satisfactory.
引用
收藏
页码:618 / 621
页数:16
相关论文
共 48 条
  • [1] Sequential quadratic programming-genetic algorithm and its application in ultrasonic localization of partial discharge in power transformers
    Liu, Hualong
    Hu, Po
    Dianwang Jishu/Power System Technology, 2015, 39 (01): : 130 - 135
  • [2] Acoustic partial discharge localization methodology in power transformers employing the quantum genetic algorithm
    Liu, Hua-Long
    APPLIED ACOUSTICS, 2016, 102 : 71 - 78
  • [3] Partial Discharge Detection and Localization in Power Transformers based on Acoustic Emission: Theory, Methods, and Recent Trends
    Rathod, Viral B.
    Kumbhar, Ganesh B.
    Bhalja, Bhavesh R.
    IETE TECHNICAL REVIEW, 2022, 39 (03) : 540 - 552
  • [4] A Machine Learning Based Hybrid Algorithm for Partial Discharge Localization in Power Transformers
    Kashani-Gharavi, Dorsay
    Faraji-Dana, Reza
    Mirzaei, Hassan Reza
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2024,
  • [5] Quantitative Comparison of Partial Discharge Localization Algorithms on Power Transformers Based on Acoustic Method
    Wang, Yan-Bo
    Qin, Shao-Rui
    Wang, Liu-Fang
    Ding, Guo-Cheng
    Li, Jian-Lin
    Zhu, Tai-Yun
    Zhang, Guan-Jun
    2018 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2018, : 542 - 545
  • [6] Partial discharge localization in power transformers using acoustic time reversal
    Karami, Hamidreza
    Aviolat, Florent Quentin
    Azadifar, Mohammad
    Rubinstein, Marcos
    Rachidi, Farhad
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 206
  • [7] Study on Location of Acoustic Emission Partial Discharge Detection in Power Transformers
    Zhang, Linhai
    Liu, Gang
    Li, Cheng
    Li, Yanming
    Zhang, Longjun
    Lu, Guojun
    2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 589 - +
  • [8] Development of Acoustic Emission Sensor Optimized for Partial Discharge Monitoring in Power Transformers
    Sikorski, Wojciech
    SENSORS, 2019, 19 (08)
  • [9] Simultaneous location of two partial discharge sources in power transformers based on acoustic emission using the modified binary partial swarm optimisation algorithm
    Hooshmand, Rahmat Allah
    Parastegari, Moein
    Yazdanpanah, Masoud
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2013, 7 (02) : 119 - 127
  • [10] Ultrasonic localization of Partial Discharge in Power Transformer Based on Improved Genetic Algorithm
    Ren, Shuangzan
    Yang, Xu
    Zhu, Ruihua
    Xi, Baofeng
    Cao, Xiaolong
    ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 99 - 99