Femoral nerve lesion in total hip replacement: an experimental study

被引:14
|
作者
Heller, KD
Prescher, A
Birnbaum, K
Forst, R
机构
[1] Rhein Westfal TH Aachen Hosp, Orthopad Klin, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Fac Med, Inst Anat 1, D-5100 Aachen, Germany
关键词
D O I
10.1007/s004020050216
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A total of 20 hip joints of 10 non-fixed corpses were examined within 48 h of death to measure the pressure below the inguinal ligament simulating the surgical conditions during total hip arthroplasty. The purpose of this study was to assess the influence of various leg positions and insertion techniques of retractors during the surgical procedure for total hip replacement in order to detect supposed causes for indirect pressure injuries of the femoral nerve. The obtained results verified no increase of pressure in the inguinal canal which could explain an indirect injury of the femoral nerve. If the retractor is inserted correctly at the anterior acetabular rim, the pressure in the lacuna musculorum can even be reduced, and furthermore, the femoral nerve is protected by the iliopsoas muscle. Femoral nerve lesions which have been published so far can only be explained by an incorrect use of instruments or implants (e.g., screws, cement, acetabular cup) or an extreme postoperative leg length discrepancy.
引用
收藏
页码:153 / 155
页数:3
相关论文
共 50 条
  • [31] Complete femoral nerve division at total hip arthroplasty
    Fabre, T
    Bernez, J
    DeCoucy, F
    DelVillar, SR
    Durandeau, A
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (01): : 148 - 149
  • [32] COMPARATIVE EXPERIMENTAL STUDY OF STRESSES IN FEMORAL TOTAL HIP-REPLACEMENT COMPONENTS - EFFECTS OF PROSTHESES ORIENTATION AND ACRYLIC FIXATION
    MARKOLF, KL
    AMSTUTZ, HC
    JOURNAL OF BIOMECHANICS, 1976, 9 (02) : 73 - &
  • [33] Accuracy of femoral templating in reproducing anatomical femoral offset in total hip replacement
    Davies, H.
    Foote, J.
    Spencer, R. F.
    HIP INTERNATIONAL, 2007, 17 (03) : 155 - 159
  • [34] Robot-assisted implantation of femoral components in hip replacement - An experimental study
    Jerosch, J
    Finken, N
    Filler, T
    Peuker, E
    Rahgozar, M
    Lahmer, A
    Witzel, U
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1999, 137 (04): : OA7 - OA12
  • [35] The role of retraction in direct nerve injury in total hip replacement AN ANATOMICAL STUDY
    McConaghie, F. A.
    Payne, A. P.
    Kinninmonth, A. W. G.
    BONE & JOINT RESEARCH, 2014, 3 (06): : 212 - 216
  • [36] Update on nerve palsy associated with total hip replacement
    Schmalzried, TP
    Noordin, S
    Amstutz, HC
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (344) : 188 - 206
  • [37] Sciatic nerve palsy after total hip replacement
    Sosna, A
    Pokorny, D
    Jahoda, D
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (08): : 1140 - 1141
  • [38] NERVE LESIONS AFTER TOTAL HIP-REPLACEMENT
    AHLGREN, SA
    ELMQVIST, D
    LJUNG, P
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (02): : 152 - 155
  • [39] FATIGUE FRACTURES OF FEMORAL PROSTHESIS IN TOTAL HIP-REPLACEMENT
    CHARNLEY, J
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1976, 58 (03): : 390 - 390
  • [40] REPLACEMENT OF FEMORAL-NECK FRACTURES BY TOTAL HIP ENDOPROTHESES
    ANSORGE, D
    HACK, U
    ZENTRALBLATT FUR CHIRURGIE, 1983, 108 (24): : 1584 - 1596