Femoral nerve lesion in total hip replacement: an experimental study

被引:14
|
作者
Heller, KD
Prescher, A
Birnbaum, K
Forst, R
机构
[1] Rhein Westfal TH Aachen Hosp, Orthopad Klin, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Fac Med, Inst Anat 1, D-5100 Aachen, Germany
关键词
D O I
10.1007/s004020050216
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A total of 20 hip joints of 10 non-fixed corpses were examined within 48 h of death to measure the pressure below the inguinal ligament simulating the surgical conditions during total hip arthroplasty. The purpose of this study was to assess the influence of various leg positions and insertion techniques of retractors during the surgical procedure for total hip replacement in order to detect supposed causes for indirect pressure injuries of the femoral nerve. The obtained results verified no increase of pressure in the inguinal canal which could explain an indirect injury of the femoral nerve. If the retractor is inserted correctly at the anterior acetabular rim, the pressure in the lacuna musculorum can even be reduced, and furthermore, the femoral nerve is protected by the iliopsoas muscle. Femoral nerve lesions which have been published so far can only be explained by an incorrect use of instruments or implants (e.g., screws, cement, acetabular cup) or an extreme postoperative leg length discrepancy.
引用
收藏
页码:153 / 155
页数:3
相关论文
共 50 条
  • [1] Femoral nerve lesion in total hip replacement: an experimental study
    K.-D. Heller
    A. Prescher
    K. Birnbaum
    R. Forst
    Archives of Orthopaedic and Trauma Surgery, 1998, 117 : 153 - 155
  • [2] ADDITIONAL NERVE-LESION IN CASES OF TOTAL HIP-REPLACEMENT
    HUNERBERG, V
    FRIEDEBOLD, G
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1977, 115 (03): : 396 - 397
  • [3] An experimental study of femoral cement stress in total hip replacement - influence of structural stiffness of the femoral stem
    Miles, A.W.
    Dall, D.M.
    Engineering in Medicine, 1985, 14 (03): : 133 - 135
  • [4] A conservative femoral replacement for total hip arthroplasty - A prospective study
    Morrey, BF
    Adams, RA
    Kessler, M
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (07): : 952 - 958
  • [5] Femoral Considerations for Total Hip Replacement in Hip Dysplasia
    Perry, Kevin I.
    Berry, Daniel J.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2012, 43 (03) : 377 - +
  • [6] FALSE ANEURYSM IN THE GROIN AND FEMORAL NERVE PALSY FOLLOWING TOTAL HIP-REPLACEMENT
    VANBOCKEL, JH
    KOOPMANN, MDE
    VANLANGELAAN, EJ
    VASA-JOURNAL OF VASCULAR DISEASES, 1980, 9 (03): : 214 - 217
  • [7] Pressure monitoring of the femoral nerve during total hip replacement: an explanation for iatropathic palsy
    Slater, N
    Singh, R
    Senasinghe, N
    Gore, R
    Goroszeniuk, T
    James, D
    JOURNAL OF THE ROYAL COLLEGE OF SURGEONS OF EDINBURGH, 2000, 45 (04): : 231 - 233
  • [8] Femoral subsidence assessment after hip replacement - An experimental study
    Ilchmann, Thomas
    Eingartner, Christoph
    Heger, Katharina
    Weise, Kuno
    UPSALA JOURNAL OF MEDICAL SCIENCES, 2006, 111 (03) : 361 - 369
  • [9] Femoral cementing techniques in total hip replacement
    Rice, J
    Prenderville, T
    Murray, P
    McCormack, B
    Quinlan, W
    INTERNATIONAL ORTHOPAEDICS, 1998, 22 (05) : 308 - 311
  • [10] Femoral osteolysis following total hip replacement
    Dattani, R.
    POSTGRADUATE MEDICAL JOURNAL, 2007, 83 (979) : 312 - 316