Damage tests for 355 nm laser mirror by using a new, variable spot size optical system (VariSpot®)

被引:0
|
作者
Fenic, Constantin [1 ]
Neagu, Liviu [1 ]
Viespe, Cristian [1 ]
Honciuc, Gheorghe [2 ]
Nemes, George [3 ]
机构
[1] Natl Inst Laser Plasma & Radiat Phys, Laser Dept, 409 Atomistilor St, Bucharest, Romania
[2] OPTICOAT, Bucharest, Romania
[3] ASTiGMAT, Santa Clara, CA 95050 USA
来源
ADVANCED LASER TECHNOLOGIES 2006 | 2007年 / 6606卷
关键词
laser-induced damage; variable spot-size optics; beam diagnostics; 355 nm high reflectance mirror;
D O I
10.1117/12.729517
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report preliminary measurements on the catastrophic damage threshold and also on the maximum fluence/irradiance for non-damage of a 355 nm high reflectance mirror, by using a new optical arrangement. Our goal was two-fold: to determine the ability of a new, variable spot size (zoom) optical system (named VariSpoe) to be used in laser-induced damage measurements, and also to characterize the damage properties of the mirror under test. The classical measurement scheme maintains a constant spot size on the target by using a fixed-focus optical system, and the laser fluence/irradiance on the target is varied by appropriately attenuating the laser beam before the focusing optics. In contrast, our scheme maintains constant the energy/power of the incoming beam before the focusing optics and uses a zoom-type optical system to continuously change the spot size and correspondingly the fluence/irradiance on the target, while keeping constant the working distance (from optics to target). A 355 nm beam representing the third harmonic of an electro-optically Q-switched, unstable cavity Nd:YAG laser was used as incoming beam. Its spatial diagnostics was done by using a CMOS-type beam profiler and following the definitions and recommendations of the ISO 11146 standard. The VariSpot optical system represents a prototype with a working distance of approximately 100 mm and delivering a round and adjustable spot size with diameters from 0.085 mm to 4.3 mm at that distance for the specific 355 nm incoming laser beam. The results show the advantages of using the VariSpot system for such type of measurements and also reveal reasonable good damage properties of the tested mirror. We briefly discuss the major sources of errors in the obtained results and also suggest several ways to improve the future measurements using similar arrangements.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Coupling of spot-size converted laser diode to polymeric waveguide with 45-degree micro reflection mirror for optical surface mount technology
    Satoh, T
    Ichimura, A
    Mikami, O
    Tomaru, S
    Hikita, M
    Uchida, T
    2ND 1998 IEMT/IMC SYMPOSIUM, 1998, : 114 - 117
  • [32] Generation of uniform lines with variable size using a beam shaping hybrid zoom optical system
    Daniels, A
    Lewis, GDW
    Kanzler, K
    LASER BEAM SHAPING IV, 2003, 5175 : 24 - 38
  • [33] Comparing 18 mm vs. 12 mm spot size in hair removal using a Gentlelase 755 nm Alexandrite laser
    Nouri, K
    Chen, H
    Saghari, S
    LASERS IN SURGERY AND MEDICINE, 2002, : 75 - 75
  • [34] Double-Pass, Low-Fluence Laser Treatment Using a Large Spot-Size 1,450 nm Laser Improves Acne
    Bernstein, Eric F.
    LASERS IN SURGERY AND MEDICINE, 2009, 41 (02) : 116 - 121
  • [35] A new clock laser system for an Yb optical lattice clock using a fibre-based frequency comb stabilized to a narrow linewidth laser at 1064 nm
    Hosaka, K.
    Inaba, H.
    Nakajima, Y.
    Iwakuni, K.
    Yasuda, M.
    Kohno, T.
    Akamatsu, D.
    Onae, A.
    Hong, F-L
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 18 - 19
  • [36] A new spot-size converter concept using fiber-matched antiresonant reflecting optical waveguides
    Galarza, M
    De Mesel, K
    Verstuyft, S
    Aramburu, U
    López-Amo, M
    Moerman, I
    Van Daele, P
    Baets, R
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2003, 21 (01) : 269 - 274
  • [37] Advances on Polymer Optical Fiber Gratings Using a KrF Pulsed Laser System Operating at 248 nm
    Marques, Carlos A. F.
    Leal-Junior, Arnaldo G.
    Min, Rui
    Domingues, Maria
    Leitao, Catia
    Antunes, Paulo
    Ortega, Beatriz
    Andre, Paulo
    FIBERS, 2018, 6 (01):
  • [38] Comparing 18-versus 12-mm spot size in hair removal using a Gentlease 755-nm Alexandrite laser
    Nouri, K
    Chen, H
    Saghari, S
    Ricotti, CA
    DERMATOLOGIC SURGERY, 2004, 30 (04) : 494 - 497
  • [39] Infrared tissue imaging at on-the-spot laser delivery using an all-optical-waveguide transmitting system
    Ilev, IK
    Waynant, RW
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 281 - 284
  • [40] LONG TERM COMPARISON OF THE NEW LARGE SPOT VACUUM ASSISTED HANDPIECE vs THE SMALL SIZE TRADITIONAL HANDPIECE OF THE 800nm DIODE LASER
    Youssef, Nour
    Rizk, Alain
    Ibrahimi, Omar
    Tannous, Zeina
    LASERS IN SURGERY AND MEDICINE, 2016, 48 : 25 - 25