Application of 4D-CT in Poorly Located Parathyroid Adenomas: Surgical Correlation

被引:0
|
作者
Almeida, Joao [1 ]
Antunes, Natalie [1 ]
do Rosario, Francisco [2 ]
Garrao, Antonio [2 ]
Cid, Maria Olimpia [3 ]
Allen, Miguel [3 ]
Mendonca, Evelina [4 ]
Leal, Cecilia [1 ]
Figueiredo, Luisa [1 ]
Marques, Hugo [5 ,6 ]
机构
[1] Hosp Santa Marta, Serv Radiol, Ctr Hosp Lisboa Cent, Lisbon, Portugal
[2] Hosp Luz, Serv Endocrinol, Lisbon, Portugal
[3] Hosp Luz, Serv Cirurgia Gearl, Lisbon, Portugal
[4] Hosp Luz, Serv Anat Patol, Lisbon, Portugal
[5] Hosp Luz, Serv Radiol, Lisbon, Portugal
[6] Hosp Santa Marta, Ctr Hosp Lisboa Cent, Lisbon, Portugal
关键词
Adenoma/diagnostic imaging; Four-Dimensional Computed Tomography; Parathyroid Glands/diagnostic imaging; Parathyroid Neoplasms/diagnostic imaging; Preoperative Care; PRIMARY HYPERPARATHYROIDISM; COMPUTED-TOMOGRAPHY; LOCALIZATION; ACCURACY; MDCT; CT;
D O I
10.1016/j.rpedm.14.1.AO180041
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Presurgical localization of parathyroid adenomas is important, improving surgical outcome and reducing its morbility. In the last years, cervico-thoracic four-dimensional computed tomography (4D-CT) has emerged as a complementary imaging technique to the traditional methods (ultrasound and scintigraphy) for presurgical localization of parathyroid adenomas of unknown location. We reviewed our initial experience in the use of 4D-CT in adults with primary hyperparathyroidism and negative or inconclusive traditional imaging modalities. Methods: Inclusion criteria were consecutive adults with primary hyperparathyroidism with negative or inconclusive traditional imaging modalities, who underwent 4D-CT and later curative surgery, between May 2015 and December 2017. We compared the report and images from 4D-CT to the histopathologic report after surgery. Results: Of the eleven patients who underwent cervical surgery, in 91% the histology was parathyroid adenoma (n=10) and in 9% parathyroid hyperplasia (n=1), with lowering of intraoperative parathyroid hormone in 77% of patients (n=7) and normalization of parathyroid hormone after surgery in 91% (n=10). 4D-CT identified all the cases of hyperfunctioning parathyroid tissue (n=11). Ultrasound and scintigraphy identified, respectively, 36% (n=4) and 18% (n=2) of the lesions. Conclusion: 4D-CT is a promising modality for localization of parathyroid adenomas of unknown location, as showed by our initial results, and should be considered in cases where ultrasound or scintigraphy were negative or inconclusive.
引用
收藏
页码:35 / 39
页数:5
相关论文
共 50 条
  • [31] Breathing pattern analysis of 4D-CT and 4D-MRI
    Higuchi, Satomi
    Goodwin, Jonathan
    OConnor, Laura
    Zerafa, Amy
    Greer, Peter
    Ludbrook, Jane
    Simpson, John
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2021, 17 : 24 - 24
  • [32] Improvement of the cine-CT based 4D-CT imaging
    Pan, Tinsu
    Sun, Xiaojun
    Luo, Dershan
    MEDICAL PHYSICS, 2007, 34 (11) : 4499 - 4503
  • [33] Parathyroid Gland Localization in Primary Hyperparathyroidism: Evaluation of a Novel Imaging Protocol and Direct Head-to-Head Comparison of Parathyroid 4D-CT and Sestamibi SPECT/CT
    Yeh, Randy
    Tay, Yu-Kwang Donovan
    Tabacco, Gaia
    Dercle, Laurent
    Kuo, Jennifer
    Bandeira, Leonardo
    Mcmanus, Catherine
    Lee, James
    Bilezikian, John
    JOURNAL OF BONE AND MINERAL RESEARCH, 2018, 33 : 63 - 64
  • [34] 4D-CT reconstruction based on pulmonary average CT values
    Zhang Shu-xu
    Zhou Ling-hong
    Lin Sheng-qu
    Yu Hui
    Zhang Guo-quan
    Wang Rui-hao
    Qi Bing
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 85 - 94
  • [35] Evaluation of four-dimensional computed tomography (4D-CT)-based pulmonary ventilation: The high correlation between 4D-CT ventilation and 81mKr-planar images was found
    Kanai, Takayuki
    Kadoya, Noriyuki
    Ito, Kengo
    Kishi, Kazuma
    Dobashi, Suguru
    Yamamoto, Takaya
    Umezawa, Rei
    Matsushita, Haruo
    Takeda, Ken
    Jingu, Keiichi
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 (03) : 444 - 448
  • [36] A Correlation Study on Position and Volume Variation of Primary Lung Cancer During Respiration by 4D-CT
    Ying-jie, Z.
    Jian-bin, L.
    Shi-yu, T.
    Feng-xiang, L.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S196 - S196
  • [37] Preoperative [99mTc]MIBI SPECT/CT Interpretation Criteria for Localization of Parathyroid Adenomas-Correlation with Surgical Findings
    Keidar, Zohar
    Solomonov, Elena
    Karry, Rachel
    Frenkel, Alex
    Israel, Ora
    Mekel, Michal
    MOLECULAR IMAGING AND BIOLOGY, 2017, 19 (02) : 265 - 270
  • [38] A CORRELATION STUDY ON POSITION AND VOLUME VARIATION OF PRIMARY LUNG CANCER DURING RESPIRATION BY 4D-CT
    Zhang, Ying-Jie
    Li, Jianbin
    JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) : S1118 - S1118
  • [39] Application of 4D-CT Scanning in Differential Diagnosis of Arytenoid Subluxation and Vocal Fold Paralysis
    Wang, Jian-an
    Xu, Xinlin
    Ma, Yanli
    Zhuang, Peiyun
    Wang, Yong
    JOURNAL OF VOICE, 2022, 36 (06) : 859 - 867
  • [40] 4D-CT angiography differentiating arteriovenous fistula subtypes
    Beijer, Tim R.
    van Dijk, Ewoud J.
    de Vries, Joost
    Vermeer, Sarah E.
    Prokop, Mathias
    Meijer, Frederick J. A.
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2013, 115 (08) : 1313 - 1316