New intraocular lens for achromatizing the human eye

被引:42
|
作者
Lopez-Gil, Norberto
Montes-Mico, Robert
机构
[1] Univ Valencia, Optometry Res Grp, E-46100 Valencia, Spain
[2] Univ Murcia, CiVi UM, E-30001 Murcia, Spain
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2007年 / 33卷 / 07期
关键词
D O I
10.1016/j.jcrs.2007.03.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To describe the design of a new intraocular lens (IOL) capable of correcting spherical and chromatic aberrations when implanted in the human eye. SETTING: University of Murcia, Murcia, and University of Valencia, Valencia, Spain. METHODS: A hybrid singlet achromatic IOL was designed. The IOL has a combination of a refractive and a diffractive surface, with 1 of the surfaces being aspherical. Optical simulations were used to model the polychromatic modulation transfer function (MTF) in pseudophakic eyes to explain the differences in optical quality afforded by the achromatic IOL. Parameters such as focus shift, optical path difference, through-focus, and robustness to tilt and decentering of achromatic IOLs were obtained. RESULTS: The polychromatic MTF in an eye with a centered, not tilted achromatic IOL was near the diffraction-limited MTF. The focus shift change for the achromatic IOL through the visible spectrum was approximately 0.1 diopter. The polychromatic MTF in an eye with the achromatic IOL would be similar to that in an eye with a spherically centered IOL if the achromatic IOL were decentered 1.0 mm or tilted 4 degrees. The range of centration and tilt error for the achromatic IOL to obtain an optical benefit in the polychromatic MTF was larger than the typical postoperative IOL decentration and tilt errors. CONCLUSION: The hybrid singlet achromatic IOL design resolved the chromatic aberration problem, improving the overall optical quality in the human eye.
引用
收藏
页码:1296 / 1302
页数:7
相关论文
共 50 条
  • [21] Eye models for the prediction of contrast vision in patients with new intraocular lens designs
    Piers, PA
    Norrby, NES
    Mester, U
    OPTICS LETTERS, 2004, 29 (07) : 733 - 735
  • [22] Intraocular lens designed for the newborn infant eye
    Lundvall, A
    Kugelberg, U
    vander Mooren, M
    vander Mooren, M
    Zetterstrom, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (06): : 928 - 933
  • [23] USE OF AN ACHROMATIZING LENS AND ITS COMPONENTS TO VARY THE AMOUNTS OF LONGITUDINAL AND TRANSVERSE CHROMATIC ABERRATION PRESENT IN THE EYE
    BOBIER, WR
    CAMPBELL, MCW
    HINCH, M
    SIMONET, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 1211 - 1211
  • [24] Clinical performance after implantation of an EDOF intraocular lens in the dominant eye and a presbyopia-correcting intraocular lens in the nondominant eye
    Soscia, William L.
    Derojas, Joaquin O.
    Mathews, Priya M.
    Brutsky, Amy
    Solomon, Kerry D.
    Potvin, Richard
    Sandoval, Helga P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (06): : 578 - 584
  • [25] Implanting a clear intraocular lens in one eye and a yellow lens in the other eye: A case series
    Olson, Michael D.
    Miller, Kevin M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) : 957 - 958
  • [26] Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens
    Montes-Mico, Robert
    Ferrer-Blasco, Teresa
    Charman, W. Neil
    Cervino, Alejandro
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (05): : 763 - 768
  • [27] Numerical Study of Natural Convection in the Anterior Chamber of Human Eye with Implanted Intraocular Lens
    Niazi, Mehdi
    Esteghamatian, Amir
    Abouali, Omid
    Ghaffariyeh, Alireza
    Ahmadi, Goodarz
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2012, VOL 1, 2012, : 1007 - 1012
  • [28] New Intraocular lens technology
    Olson, RJ
    Werner, L
    Mamalis, N
    Cionni, R
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (04) : 709 - 716
  • [29] Accommodation in the primate eye following intraocular lens implantation
    McDonald, JP
    Croft, MA
    Vinje, E
    Gwon, A
    Laguette, SW
    Heatley, GA
    Kaufman, PL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U707 - U707
  • [30] INTRAOCULAR-LENS CALCULATION - THE PROBLEM OF THE SHORT EYE
    HOFFER, KJ
    OPHTHALMIC SURGERY AND LASERS, 1981, 12 (04): : 269 - 272