Composite repair patch evaluation using pulse-echo laser ultrasonic correlation mapping method

被引:20
|
作者
Lee, Young-Jun [1 ]
Lee, Jung-Ryul [1 ]
Ihn, Jeong-Beom [2 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Aerosp Engn, 291 Daehak Ro, Daejeon 34141, South Korea
[2] Boeing Res & Technol, Struct Technol, Seattle, WA USA
基金
新加坡国家研究基金会;
关键词
Composite patch inspection; Ultrasonic inspection; Laser ultrasonic; Cross-correlation imaging; Inspection result visualization; PANELS;
D O I
10.1016/j.compstruct.2018.07.124
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Composite patch bonding repair is widely applied to metal and composite aircraft repair owing to its light weight and high resistance to fatigue and corrosion. However, composite patch repairing is done by vacuum bag processing in general, and the process itself is susceptible to manufacturing defects. In addition, the composite repair patches require more frequent inspections owing to the difficulty of the damage prediction. In this paper, we propose pulse-echo laser ultrasonic correlation mapping for a rapid quality evaluation method of composite repair patching. This method uses a pulse-echo ultrasonic propagation imaging system as a tool for in-situ and full-field inspection, and an ultrasonic correlation mapping (UCM) method was developed for fast and straightforward defect visualization. Two composite patch repair specimens were tested, and then UCM results were compared with other results using existing visualization methods. We also tested a composite laminate plate to verify the applicability of UCM to general composite parts. The UCM results showed similar or better performance than current visualization methods in all cases. Test results showed that the proposed system is suitable for both in-process quality evaluation and in-service field inspection.
引用
收藏
页码:395 / 401
页数:7
相关论文
共 50 条
  • [31] A calibration methodology of ultrasonic transducers: Evaluation of spatial propagation characteristics of pulse-echo
    Yoshida, Taiki
    Wada, Sanehiro
    Furuichi, Noriyuki
    MEASUREMENT, 2023, 214
  • [32] Application of ultrasonic pulse-echo method to insulation condition diagnosis for large generators
    Hao, YP
    Wang, GL
    Jia, ZD
    Xie, HK
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (01) : 104 - 113
  • [33] METHOD TO EVALUATE DIRECT-READING ULTRASONIC PULSE-ECHO THICKNESS METERS
    BOSSELAAR, H
    GOOSSENS, JC
    MATERIALS EVALUATION, 1971, 29 (03) : 45 - +
  • [34] Pulse-echo acoustic properties evaluation method using high-frequency transducer
    Li, Zhangjian
    Han, Zhile
    Jian, Xiaohua
    Shao, Weiwei
    Jiao, Yang
    Cui, Yaoyao
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (12)
  • [35] Broadband ultrasonic pulse-echo method for estimation of local density of tungsten samples
    Kravcov, A.
    Dudchenko, O. L.
    Svoboda, P.
    Ivanov, P. N.
    Sizikov, M., V
    Belov, O. D.
    Gapeev, A. A.
    INTERNATIONAL CONFERENCE ON APPLIED PHYSICS, POWER AND MATERIAL SCIENCE, 2019, 1172
  • [36] Errors and uncertainties in the ultrasonic pulse-echo reflectometry method for measuring acoustic impedance
    Challis, RE
    Wilkinson, GP
    Freemantle, RJ
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (04) : 692 - 700
  • [37] A high-fidelity ultrasonic pulse-echo scheme for detecting delaminations in composite laminates
    Wooh, SC
    Wei, C
    COMPOSITES PART B-ENGINEERING, 1999, 30 (05) : 433 - 441
  • [38] Rotational laser ultrasonic propagation imager in pulse-echo mode for defect evaluation of type-3 COPV
    Lee, Kyu-Jin
    Hong, Seung-Chan
    Rhee, Seung Yun
    Lee, Jung-Ryul
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2025,
  • [39] Thickness measurements of curved multi-layered polymer system using ultrasonic pulse-echo method
    Maev, RG
    Shao, H
    Maeva, EY
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 17A AND 17B, 1998, : 1665 - 1672
  • [40] Improvement of axial resolution of pulse-echo ultrasonic image using the wavelet transform
    Hamamoto, K
    Nishimura, T
    Saito, M
    SIMULATIONS IN BIOMEDICINE IV, 1997, : 331 - 336