Fast bound pool fraction mapping via steady-state magnetization transfer saturation using single-shot EPI

被引:8
|
作者
Battiston, Marco [1 ]
Schneider, Torben [2 ]
Grussu, Francesco [1 ,3 ]
Yiannakas, Marios C. [1 ]
Prados, Ferran [1 ,4 ,5 ]
De Angelis, Floriana [1 ]
Wheeler-Kingshott, Claudia A. M. Gandini [1 ,6 ,7 ]
Samson, Rebecca S. [1 ]
机构
[1] UCL, Fac Brain Sci, UCL Inst Neurol, Queen Sq MS Ctr,Dept Neuroinflammat, London, England
[2] Philips UK, Guildford, Surrey, England
[3] UCL, Dept Comp Sci, Ctr Med Image Comp, London, England
[4] UCL, Dept Med Phys & Biomed Engn, Ctr Med Image Comp, London, England
[5] Univ Oberta Catalunya, Barcelona, Spain
[6] Univ Pavia, Dept Brain & Behav Sci, Pavia, Italy
[7] IRCCS Mondino Fdn, Brain MRI 3T Res Ctr, Pavia, Italy
基金
英国工程与自然科学研究理事会; 欧盟地平线“2020”;
关键词
2-pool model; bound pool fraction; EPI; magnetization transfer; myelin; quantitative steady-state; INHOMOGENEOUSLY BROADENED LINES; QUANTITATIVE INTERPRETATION; INVERSION-RECOVERY; TRANSFER CONTRAST; HIGH-RESOLUTION; MYELIN CONTENT; SIZE RATIO; RELAXATION; BRAIN; MODEL;
D O I
10.1002/mrm.27792
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To enable clinical applications of quantitative magnetization transfer (qMT) imaging by developing a fast method to map one of its fundamental model parameters, the bound pool fraction (BPF), in the human brain. Theory and Methods: The theory of steady-state MT in the fast-exchange approximation is used to provide measurements of BPF, and bound pool transverse relaxation time (T-2(B)). A sequence that allows sampling of the signal during steady-state MT saturation is used to perform BPF mapping with a 10-min-long fully echo planar imaging-based MRI protocol, including inversion recovery T-1 mapping and B-1 error mapping. The approach is applied in 6 healthy subjects and 1 multiple sclerosis patient, and validated against a single-slice full qMT reference acquisition. Results: BPF measurements are in agreement with literature values using off-resonance MT, with average BPF of 0.114(0.100-0.128) in white matter and 0.068(0.054-0.085) in gray matter. Median voxel-wise percentage error compared with standard single slice qMT is 4.6%. Slope and intercept of linear regression between new and reference BPF are 0.83(0.81-0.85) and 0.013(0.11-0.16). Bland-Altman plot mean bias is 0.005. In the multiple sclerosis case, the BPF is sensitive to pathological changes in lesions. Conclusion: The method developed provides accurate BPF estimates and enables shorter scan time compared with currently available approaches, demonstrating the potential of bringing myelin sensitive measurement closer to the clinic.
引用
收藏
页码:1025 / 1040
页数:16
相关论文
共 47 条
  • [41] Editorial for "pH Mapping of Gliomas Using Quantitative Chemical Exchange Saturation Transfer MRI: Quasi-Steady-State, Spillover-, and MT-Corrected Omega Plot Analysis"
    Levesque, Ives R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (04) : 1456 - 1457
  • [42] Fast T2 mapping of short-T2 tissues in knee using 3D radial dual-echo balanced steady-state free precession
    Li, Bowen
    Ding, Zekang
    She, Huajun
    MAGNETIC RESONANCE IMAGING, 2024, 107 : 149 - 159
  • [43] Non-Contrast Enhanced MR Angiography (NCE-MRA) of the Calf: A Direct Comparison between Flow-Sensitive Dephasing (FSD) Prepared Steady-State Free Precession (SSFP) and Quiescent-Interval Single-Shot (QISS) in Patients with Diabetes
    Zhang, Na
    Zou, Liqiu
    Huang, Yi
    Liu, Dexiang
    Tang, Yukuan
    Fan, Zhaoyang
    Chen, Hanwei
    Liu, Xin
    PLOS ONE, 2015, 10 (06):
  • [44] Whole-Brain Amide Proton Transfer (APT) and Nuclear Overhauser Enhancement (NOE) Imaging in Glioma Patients Using Low-Power Steady-State Pulsed Chemical Exchange Saturation Transfer (CEST) Imaging at 7T
    Heo, Hye-Young
    Jones, Craig K.
    Hua, Jun
    Yadav, Nirbhay
    Agarwal, Shruti
    Zhou, Jinyuan
    van Zijl, Peter C. M.
    Pillai, Jay J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (01) : 41 - 50
  • [45] Development of a Comprehensive Cardiac MRI Atlas of Half Fourier-Acquired Single-Shot Turbo Spin-Echo (HASTE) and 3D Balanced Steady-State Free Precession (bSSFP) Sequences Prospectively Acquired From a 1.5T MR-Linac
    Schottstaedt, A. M.
    Paulson, E. S.
    Rubenstein, J.
    Chen, X.
    Omari, E.
    Li, A.
    Gore, E. M.
    Schultz, C. J.
    Hall, W. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E75 - E76
  • [46] Formulation of high-temperature strength equation of 9Cr-ODS tempered martensitic steels using the Larson-Miller parameter and life-fraction rule for rupture life assessment in steady-state, transient, and accident conditions of fast reactor fuel
    Miyazawa, Takeshi
    Tanno, Takashi
    Imagawa, Yuya
    Hashidate, Ryuta
    Yano, Yasuhide
    Kaito, Takeji
    Ohtsuka, Satoshi
    Mitsuhara, Masatoshi
    Toyama, Takeshi
    Ohnuma, Masato
    Nakashima, Hideharu
    JOURNAL OF NUCLEAR MATERIALS, 2024, 593
  • [47] A PHENOMENOLOGICAL MODEL OF THE THERMAL-HYDRAULICS OF CONVECTIVE BOILING DURING THE QUENCHING OF HOT ROD BUNDLES .3. MODEL ASSESSMENT USING WINFRITH STEADY-STATE, POST-CHF, VOID-FRACTION AND HEAT-TRANSFER MEASUREMENTS AND BERKELEY TRANSIENT-REFLOOD TEST DATA
    UNAL, C
    NELSON, R
    HAYTCHER, E
    NUCLEAR ENGINEERING AND DESIGN, 1993, 140 (02) : 211 - 227