Medical applications of optically stimulated luminescence dosimeters (OSLDs)

被引:44
|
作者
Yukihara, E. G. [1 ]
Gasparian, P. B. R. [1 ]
Sawakuchi, G. O. [2 ]
Ruan, C. [3 ]
Ahmad, S. [4 ]
Kalavagunta, C. [3 ]
Clouse, W. J. [3 ]
Sahoo, N. [2 ]
Titt, U. [2 ]
机构
[1] Oklahoma State Univ, Dept Phys, Stillwater, OK 74078 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[3] Univ Oklahoma, Hlth Sci Ctr, Dept Radiol Sci, Oklahoma City, OK USA
[4] Univ Oklahoma, Hlth Sci Ctr, Dept Radiat Oncol, Oklahoma City, OK USA
关键词
Optically stimulated luminescence; Radiotherapy; Proton therapy; Medical dosimetry; Diagnostic radiology; DOSE-RESPONSE; AL2O3-C; DEPENDENCE; PROTON; SYSTEM; PHOTON; ELECTRON;
D O I
10.1016/j.radmeas.2009.12.034
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This work presents an overview of the advances in the application of optically stimulated luminescence (OSL) to dosimetry in diagnostic radiology and radiation therapy achieved by the Oklahoma State University group in collaboration with the University of Oklahoma Health Sciences Center and the University of Texas M. D. Anderson Cancer Center. This overview discusses: (a) the development and demonstration of readout protocols for high-precision dosimetry in radiation therapy using high-energy photons and electrons; (b) the determination of dose profiles inside acrylic phantom in computed tomography; and (c) the performance of OSL dosimeters for dosimetry of proton therapeutic beams, including point measurements in air and along pristine and spread-out Bragg peaks. Our results demonstrate the capability of performing high-precision measurements (experimental standard deviation of 0.7%) in radiotherapy and show the possibility of performing one-dimensional dose mapping in X-ray computed tomography and proton beams. In the case of protons, our results show that OSL dosimeters are energy independent for protons with energies above 100 MeV, but a reduction in efficiency is observed at the end of the proton range. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:658 / 662
页数:5
相关论文
共 50 条
  • [21] General radiographic attributes of optically stimulated luminescence dosimeters: A basic insight
    Musa, Y.
    Hashim, S.
    Ghoshal, S. K.
    Bradley, D. A.
    Ahmad, N. E.
    Karim, M. K. A.
    Hashim, A.
    Kadir, A. B. A.
    RADIATION PHYSICS AND CHEMISTRY, 2018, 147 : 1 - 6
  • [22] Remote auditing of radiotherapy facilities using optically stimulated luminescence dosimeters
    Lye, Jessica
    Dunn, Leon
    Kenny, John
    Lehmann, Joerg
    Kron, Tomas
    Oliver, Chris
    Butler, Duncan
    Alves, Andrew
    Johnston, Peter
    Franich, Rick
    Williams, Ivan
    MEDICAL PHYSICS, 2014, 41 (03)
  • [23] In vivo dosimetry with optically stimulated luminescent dosimeters, OSLDs, compared to diodes; the effects of buildup cap thickness and fabrication material
    Jursinic, Paul A.
    Yahnke, Clifford J.
    MEDICAL PHYSICS, 2011, 38 (10) : 5432 - 5440
  • [24] Insect wings as retrospective/accidental/forensic dosimeters: An optically stimulated luminescence investigation
    Kazakis, Nikolaos A.
    Tsetine, Anastasia Th.
    Kitis, George
    Tsirliganis, Nestor C.
    RADIATION MEASUREMENTS, 2016, 89 : 74 - 81
  • [25] Monitoring total skin electron therapy using optically stimulated luminescence dosimeters
    Kairn, T.
    Wilks, R.
    Yu, L.
    Crowe, S.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S952 - S953
  • [26] Suitability of Topaz Glass Composites as Dosimeters Using Optically Stimulated Luminescence Technique
    Sardar, M.
    Souza, D. N.
    Groppo, D. P.
    Caldas, L. V. E.
    Tufail, M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 850 - 854
  • [27] Optically Stimulated Luminescence (OSL) Dosimeters Can Be Used for Remote Dosimetry Services
    Homnick, J.
    Ibbott, G.
    Springer, A.
    Aguirre, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [28] Performance of Al2O3:C optically stimulated luminescence dosimeters for clinical radiation therapy applications
    B. Hu
    Y. Wang
    W. Zealey
    Australasian Physical & Engineering Sciences in Medicine, 2009, 32 : 226 - 232
  • [29] Performance of Al2O3:C optically stimulated luminescence dosimeters for clinical radiation therapy applications
    Hu, B.
    Wang, Y.
    Zealey, W.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2009, 32 (04) : 226 - 232
  • [30] Optically stimulated luminescence and its use in medical dosimetry
    Akselrod, M. S.
    Botter-Jensen, L.
    McKeever, S. W. S.
    RADIATION MEASUREMENTS, 2006, 41 : S78 - S99