Comparison of Measurement Reliability of Nanosecond Rectangular Voltage Pulses by Kerr Effect and by High-Speed Voltage Probe

被引:2
|
作者
Arandelovic, Nemanja [1 ]
Nikezic, Dusan [2 ]
Brajovic, Dragan [3 ]
Ramadani, Uzahir [2 ]
机构
[1] Univ Belgrade, Fac Technol & Met, Belgrade, Serbia
[2] Univ Belgrade, VINCA Inst Nucl Sci, Natl Inst Republ Serbia, Belgrade, Serbia
[3] Univ Kragujevac, Fac Tech Sci, Kragujevac, Serbia
关键词
Kerr electro-optic effect; fast capacitive probe; nanosecond pulses; plasma heating; FILLED SURGE ARRESTERS; GAS; DESIGN; VERIFICATION; DIVIDER; SYSTEM;
D O I
10.1080/15361055.2022.2031690
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Recently, the idea of injecting energy with electromagnetic radiation in order to heat the plasma to achieve controlled fusion has been abandoned. This initially favored mechanism was rejected because it has been shown that after a certain temperature the plasma glows and acts as a mirror that reflects electromagnetic radiation. For that reason, today the energy is injected into the plasma by electrons. For this purpose, pulses from several electron beam generators, based on a Marx generator, are synchronously fired into the plasma. In addition to economic problems, the biggest problem of this method is the appearance of jitter, i.e., pulses with a width of about 5 ns are not simply added up but propagated in time due to the impossibility of synchronizing simultaneous triggering of the multiple electronic generators. In order to avoid this, the possibility of monitoring the pulses from an individual electron beam generator for the purpose of online synchronization is investigated in this paper. The voltage pulse monitoring of the electron beam generator was measured by instruments with the fastest response-the electro-optical Kerr effect and a fast capacitive probe. The obtained results showed that the electro-optical Kerr response is somewhat faster but much more complicated, so the use of fast capacitive probes is recommended for practice.
引用
收藏
页码:369 / 378
页数:10
相关论文
共 50 条
  • [31] Broadband Power Measurement of High-Voltage, Nanosecond Electric Pulses for Biomedical Applications
    Sanders, J.
    Jiang, C.
    Kuthi, A.
    Gundersen, M. A.
    PROCEEDINGS OF THE 2008 IEEE INTERNATIONAL POWER MODULATORS AND HIGH VOLTAGE CONFERENCE, 2008, : 350 - 353
  • [32] GENERATOR OF HIGH-VOLTAGE NANOSECOND PULSES FOR FIRING HIGH-VOLTAGE DISCHARGE GAPS
    IVANOV, IT
    TRIFONOV, AI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1984, 27 (03) : 641 - 642
  • [33] Design and Implementation of High-Voltage High-Speed Optically Controlled Pulses Thyristor
    Wang, Lingyun
    Liu, Hongwei
    Yuan, Jianqiang
    Xie, Weiping
    Yan, Jiasheng
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (23): : 7566 - 7576
  • [34] NANOSECOND CURRENT PROBE FOR HIGH-VOLTAGE EXPERIMENTS
    KROMPHOLZ, H
    DOGGETT, J
    SCHOENBACH, KH
    GAHL, J
    HARJES, C
    SCHAEFER, G
    KRISTIANSEN, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1984, 55 (01): : 127 - 128
  • [35] HIGH-SPEED VOLTAGE-FOLLOWER HAS ONLY 1-NANOSECOND DELAY
    HORNA, OA
    ELECTRONICS, 1973, 46 (15): : 115 - 116
  • [36] HIGH-SPEED PRECISION VOLTAGE FOLLOWER
    DANILOV, AA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1987, 30 (01) : 92 - 94
  • [37] ACCURATE HIGH-SPEED VOLTAGE COMPARATOR
    ROBERTSON, DS
    WADSWORTH, BF
    BROWN, SE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1959, 30 (10): : 896 - 898
  • [38] GENERATOR OF TRAINS OF HIGH-VOLTAGE PULSES IN A NANOSECOND RANGE
    TIMOSHIN, IY
    KOLOBANO.EI
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1974, (01): : 101 - 103
  • [39] GENERATORS OF HIGH-VOLTAGE NANOSECOND PULSES OF COMPLEX SHAPE
    BAZHENOV, GP
    MANYLOV, VI
    SHPAK, VG
    CHESNOKOV, SM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1978, 21 (02) : 392 - 395
  • [40] Semiconductor formers of high-voltage pulses of nanosecond duration
    Aristov, Yu. V.
    Voronkov, V. B.
    Grekhov, I. V.
    Zhmodikov, A. L.
    Kozlov, A. K.
    Korotkov, S. V.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2007, 50 (03) : 350 - 352