Development of a CFD model for simulating vehicle cabin indoor air quality

被引:49
|
作者
Chang, Tong-Bou [1 ]
Sheu, Jer-Jia [2 ]
Huang, Jhong-Wei [2 ]
Lin, Yu-Sheng [1 ]
Chang, Che-Cheng [1 ]
机构
[1] Natl Chiayi Univ, Dept Mech & Energy Engn, Chiayi, Taiwan
[2] Southern Taiwan Univ Sci & Technol, Dept Mech Engn, Tainan, Taiwan
关键词
IAQ; Air leakage ventilation; Vehicle HVAC; THERMAL COMFORT; HUMID CLIMATE; VENTILATION; ENVIRONMENT; HOT;
D O I
10.1016/j.trd.2018.03.018
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
As the level of CO2 within the vehicle cabin increases, the risk of accidents as a result of driver drowsiness and a slowing of the reactions also increases. Accordingly, a CFD simulation model was developed in this study to explore the effects of outdoor air ventilation rate on vehicle cabin indoor air quality and the amount of outdoor air required for each person in a vehicle. The results show that using the outdoor air supply rate recommendations of ASHRAE Standard 62.1 (i.e. 2.5 1/s per person) the mean CO2 concentrations in the cabin are around 2850 ppm. The results also show that using the outdoor air supply rate recommendations of 4.01/s per person for improved human wellbeing, the corresponding mean CO2 concentrations in the cabin are around 1810 ppm. Moreover, the present study found that an outdoor fresh air flow rate of 9.21/s per passenger was sufficient to reduce the carbon dioxide concentration within the cabin to a safe value of 1000 ppm. Furthermore, an outdoor fresh air flow rate of 3.61/s per passenger resulted in a carbon dioxide concentration of around 2000 ppm.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 50 条
  • [1] CFD simulations of effects of recirculation mode and fresh air mode on vehicle cabin indoor air quality
    Chang, Tong-Bou
    Lin, Yu-Sheng
    Hsu, Yi-Tian
    ATMOSPHERIC ENVIRONMENT, 2023, 293
  • [2] Vehicle air leakage ventilation and its effect on cabin indoor air quality
    Chang, Tong-Bou
    Sheu, Jer-Jia
    Huang, Jhong-Wei
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2017, 231 (06) : 1226 - 1234
  • [3] Indoor air quality in the cabin of an airliner
    Gladyszewska-Fiedoruk, Katarzyna
    JOURNAL OF AIR TRANSPORT MANAGEMENT, 2012, 20 : 28 - 30
  • [4] Development of a Standard Testing Method for Vehicle Cabin Air Quality Index
    Pham, Liem
    Molden, Nick
    Boyle, Sam
    Johnson, Kent
    Jung, Heejung
    SAE INTERNATIONAL JOURNAL OF COMMERCIAL VEHICLES, 2019, 12 (02) : 151 - 161
  • [5] REAL-TIME INDOOR ENVIRONMENT QUALITY MONITORING FOR VEHICLE CABIN
    Iruthayaraj, Daniel Lawrence
    Arockiam, Rehash Rushmi Pavitra
    Subbaian, Jayabal
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2023, 22 (11): : 1801 - 1811
  • [6] Influence of vehicle age on build-up of carbon dioxide in cabin to monitor indoor air quality (IAQ)
    Mathur, G. D.
    VEHICLE THERMAL MANAGEMENT SYSTEMS CONFERENCE AND EXHIBITION (VTMS 10), 2011, : 623 - 634
  • [7] The development and validation of a thermal model for the cabin of a vehicle
    Marcos, David
    Pino, Francisco J.
    Bordons, Carlos
    Guerra, Jose J.
    APPLIED THERMAL ENGINEERING, 2014, 66 (1-2) : 646 - 656
  • [8] Ventilation control for improved cabin air quality and vehicle safety
    Galatsis, K
    Wlodarski, W
    Li, YX
    Kalantar-zadeh, K
    IEEE VTC 53RD VEHICULAR TECHNOLOGY CONFERENCE, SPRING 2001, VOLS 1-4, PROCEEDINGS, 2001, : 3018 - 3021
  • [9] CFD simulation research on residential indoor air quality
    Yang, Li
    Ye, Miao
    He, Bao-Jie
    SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 472 : 1137 - 1144
  • [10] Investigation of gas sensors for vehicle cabin air quality monitoring
    Galatsis, K
    Wlodarski, W
    Kalantar-Zadeh, K
    Trinchi, A
    COMMAD 2002 PROCEEDINGS, 2002, : 229 - 232