Flow-based Analytical Techniques

被引:1
|
作者
Suzuki, Yasutada [1 ]
机构
[1] Univ Yamanashi, Fac Life & Environm Sci, Grad Fac Interdisciplinary Res, 4-4-37 Takeda, Kofu, Yamanashi 4008510, Japan
关键词
Flow-based analytical technique; SEQUENTIAL INJECTION CHROMATOGRAPHY; SYSTEM; SPECTROMETRY; EXTRACTION;
D O I
10.2116/analsci.highlights1808
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow-injection analysis (FIA) was invented by Řužička and Hansen.1 Flow-based analytical techniques, including sequential-injection analysis (SIA),2 is widely used in various fields, such as process control, environmental, clinical, pharmaceutical, food analysis, and so on. Several types of detectors are used in flow analytical systems, of which chemiluminescence (CL) is one of the most sensitive detection methods. Hasanin et al. reported on the determination of antimony(III) and (V) using a reversed micelle system of rhodamine B-cetyltrimethylammonium chloride and online extraction and phase separation.3 A detection limit was attained as low as 0.35 μmol dm -3 . Yaqoob's group reported FIA-CL methods for the determination of thiabendazole,4 and hyoscine butylbromide,5 using diperiodatocuprate(III) ([Cu(HIO 6 ) 2 ] 5- ) and diperiodatoargentate(III) ([Ag(HIO6)2] 5- ) as oxidizing agents, respectively. Miyamoto et al. has developed an evaluation method for hydroxyl radical (•OH) scavenging activities with CL detection.6 The system uses the Fenton reaction, which produces CL by a reaction between luminol and •OH; the diminution rate of the CL is used to evaluate the scavenging activity. SIA technique is utilized to automate all of the reactions. Electrochemical detection is another sensitive method for flow-based analysis. Matsuura et al. reported on how tightly immobilized electrodeposited platinum particles on nitrogencontaining functional groups introduced glassy carbon, and its application to the determination of dissolved hydrogen molecules.7 Since SIA does not require a constant monotonous flow of a carrier or reagent solution, it can reduce their consumption compared to FIA.2 Siriangkhawut et al. reported on SIA for aluminum determination using natural chelating reagent extracts from a heartwood of Ceasalpinia sappan Linn. to establish a more eco-friendly method.8 Thaithet et al. reported on sequential injection chromatography (SIC) using an ultra-short monolithic column for the separation of a-tocopherol and γ-oryzanol in edible oils and nutrition supplements.9 The total analysis time, including column equilibration, is 16 min, and the obtained results agree well with the results from HPLC. At first, the application of SIC was limited to the determination of pharmaceutical samples; now it has been expanded to various samples, such as biological, food, and environmental analyses.10 Flow- or sequential-injection techniques can be used to preconcentrate analytes for atomic spectrometry. Tiwari et al. reported on the use of a minicolumn packed with Amberlite XAD-16 with a flow-injection technique for the online preconcentration of chromium and its determination by flame atomic absorption spectrometry.11 Ayala et al. used a sequentialinjection technique with solid-phase extraction for the determination of strontium and nickel by microwave plasma atomic emission spectrometry. A crown ether chromatographic resin and dimethylglyoxime polymethacrylate resin were used for the preconcentration of strontium and nickel, respectively.12 Sumitomo et al. used an internal standard, the amplitude modulation of flow rates for sample solutions and fast Fouriertransformation signal processing, to determine two different samples simultaneously.13 A validation of the method was demonstrated by using the determination of iron(II) with 1,10-phenanthroline. The stability of this unique system was improved by an internal standard solution (methylene blue). The development of new applications and flow-systems will be continued for more sensitive and easier determinations. © 2018 The Japan Society for Analytical Chemistry.
引用
收藏
页码:865 / 865
页数:1
相关论文
共 50 条
  • [31] Flow-Based Reinforcement Learning
    Samarasinghe, Dilini
    Barlow, Michael
    Lakshika, Erandi
    IEEE ACCESS, 2022, 10 : 102247 - 102265
  • [32] Field and flow-based separations
    Lespes, Gaetane
    Contado, Catia
    Gale, Bruce K.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (15) : 4299 - 4300
  • [33] Flow Simulator - a flow-based network simulator
    Drzewiecki, Lukasz
    Antoniak-Lewandowska, Monika
    EUROCON 2007: THE INTERNATIONAL CONFERENCE ON COMPUTER AS A TOOL, VOLS 1-6, 2007, : 2124 - 2128
  • [34] Analytical challenges and advantages of using flow-based methodologies for ammonia determination In estuarine and marine waters
    Sraj, Lenka O'Connor
    Almeida, M. Ines G. S.
    Swearer, Stephen E.
    Kolev, Spas D.
    McKelvie, Ian D.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 59 : 83 - 92
  • [35] A flow-based analytical procedure for salbutamol determination exploiting chemiluminescence in a liquid-core waveguide
    Sanchez, Mariana A.
    Rocha, Fabio R. P.
    ANALYTICAL LETTERS, 2008, 41 (09) : 1579 - 1591
  • [36] Uncapacitated flow-based extended formulations
    Samuel Fiorini
    Kanstantsin Pashkovich
    Mathematical Programming, 2015, 153 : 117 - 131
  • [37] FlowOS: A Flow-based Platform for Middleboxes
    Bezahaf, Mehdi
    Alim, Abdul
    Mathy, Laurent
    PROCEEDINGS OF THE 2013 WORKSHOP ON HOT TOPICS IN MIDDLEBOXES AND NETWORK FUNCTION VIRTUALIZATION (HOTMIDDLEBOX'13), 2013, : 19 - 24
  • [38] Graphical Flow-based Spark Programming
    Tanmaya Mahapatra
    Christian Prehofer
    Journal of Big Data, 7
  • [39] A Flow-Based Explanation for Return Predictability
    Lou, Dong
    REVIEW OF FINANCIAL STUDIES, 2012, 25 (12): : 3457 - 3489
  • [40] Flow-based TCP Connection Analysis
    Limmer, Tobias
    Dressler, Falko
    2009 IEEE 28TH INTERNATIONAL PERFORMANCE COMPUTING AND COMMUNICATIONS CONFERENCE (IPCC 2009), 2009, : 376 - 383